Title Wavelet domain compounding for speckle reduction in opticalcoherence tomography

Visibility of optical coherence tomography (OCT) images can be severely degraded by speckle noise. A computationally efficient despeckling approach that strongly reduces the speckle noise is reported. It is based on discrete wavelet transform (DWT), but eliminates the conventional process of threshold estimation. By decomposing an image into different levels, a set of sub-band images are generated, where speckle noise is additive. These sub-band images can be compounded to suppress the additive speckle noise, as DWT coefficients resulting from speckle noise tend to be approximately decorrelated. The final despeckled image is reconstructed by taking the inverse wavelet transform of the new compounded sub-band images. The performance of speckle reduction and edge preservation is controlled by a single parameter: the level of wavelet decomposition. The proposed technique is applied to intravascular OCT imaging of porcine carotid arterial wall and ophthalmic OCT images. Results demonstrate the effectiveness of this technique for speckle noise reduction and simultaneous edge preservation. The presented method is fast and easy to implement and to improve the quality of OCT images. © 2013 Society of Photo-Optical Instrumentation Engineers (SPIE) [DOI: 10.1117/1.JBO.18.9.096002]

[1]  I. Johnstone,et al.  Adapting to Unknown Smoothness via Wavelet Shrinkage , 1995 .

[2]  G. Ripandelli,et al.  Optical coherence tomography. , 1998, Seminars in ophthalmology.

[3]  J. Schmitt,et al.  Speckle in optical coherence tomography. , 1999, Journal of biomedical optics.

[4]  M. Bashkansky,et al.  Statistics and reduction of speckle in optical coherence tomography. , 2000, Optics letters.

[5]  Justin K. Romberg,et al.  Bayesian tree-structured image modeling using wavelet-domain hidden Markov models , 2001, IEEE Trans. Image Process..

[6]  B. Bouma,et al.  Speckle reduction in optical coherence tomography by "path length encoded" angular compounding. , 2003, Journal of biomedical optics.

[7]  A. Fercher,et al.  Speckle reduction in optical coherence tomography by frequency compounding. , 2003, Journal of biomedical optics.

[8]  J. Fujimoto,et al.  Speckle reduction in optical coherence tomography images by use of a spatially adaptive wavelet filter. , 2004, Optics letters.

[9]  Daniel L Marks,et al.  Speckle reduction by I-divergence regularization in optical coherence tomography. , 2005, Journal of the Optical Society of America. A, Optics, image science, and vision.

[10]  A. Low,et al.  Technology Insight: optical coherence tomography—current status and future development , 2006, Nature Clinical Practice Cardiovascular Medicine.

[11]  Aydogan Ozcan,et al.  Speckle reduction in optical coherence tomography images using digital filtering. , 2007, Journal of the Optical Society of America. A, Optics, image science, and vision.

[12]  Kostadinka Bizheva,et al.  Speckle noise reduction algorithm for optical coherence tomography based on interval type II fuzzy set. , 2007, Optics express.

[13]  Aleksandra Pizurica,et al.  Multiresolution denoising for optical coherence tomography: a review and evaluation , 2008 .

[14]  Wolfgang Drexler,et al.  Optical Coherence Tomography (OCT) in ophthalmology: introduction. , 2009, Optics express.

[15]  Shahab Chitchian,et al.  Denoising during optical coherence tomography of the prostate nerves via wavelet shrinkage using dual-tree complex wavelet transform. , 2009, Journal of biomedical optics.

[16]  Zhaoxia Yu,et al.  Speckle attenuation in optical coherence tomography by curvelet shrinkage. , 2009, Optics letters.

[17]  Dong Wang,et al.  Entropy-Based Method of Choosing the Decomposition Level in Wavelet Threshold De-noising , 2010, Entropy.

[18]  A. Curatolo,et al.  Speckle reduction in optical coherence tomography by strain compounding. , 2010, Optics letters.

[19]  Alexander V Stolin,et al.  Analysis of Image Combination Methods for Conjugate Breast Scintigraphy , 2010, IEEE Transactions on Nuclear Science.

[20]  Brendan F Kennedy,et al.  Speckle reduction in optical coherence tomography images using tissue viscoelasticity. , 2011, Journal of biomedical optics.

[21]  Yuuki Watanabe,et al.  Angular high-speed massively parallel detection spectral-domain optical coherence tomography for speckle reduction. , 2011, Journal of biomedical optics.

[22]  Edmund Y Lam,et al.  Speckle reduction of endovascular optical coherence tomography using a generalized divergence measure. , 2012, Optics letters.

[23]  Joachim Hornegger,et al.  Wavelet denoising of multiframe optical coherence tomography data , 2012, Biomedical optics express.

[24]  Massoud Motamedi,et al.  Retinal optical coherence tomography image enhancement via shrinkage denoising using double-density dual-tree complex wavelet transform , 2012, Journal of biomedical optics.

[25]  Edmund Y. Lam,et al.  Dual-Band Time-Multiplexing Swept-Source Optical Coherence Tomography Based on Optical Parametric Amplification , 2012, IEEE Journal of Selected Topics in Quantum Electronics.

[26]  Vivek Angoth,et al.  A Novel Wavelet Based Image Fusion for Brain Tumor Detection , 2013 .

[27]  Edmund Y Lam,et al.  Wavelet domain compounding for speckle reduction in optical coherence tomography , 2013, Journal of biomedical optics.

[28]  Koichi Kawano,et al.  IKONOS image fusion process using steepest descent method with bi-linear interpolation , 2013 .