A Controllable Thyristor-Based Commutation Failure Inhibitor for LCC-HVDC Transmission Systems

Commutation failure is a serious malfunction in line-commutated high voltage direct current (HVdc) converters which is mainly caused by the inverter ac faults, and results in a temporary interruption of transmitted power and damage to the converter equipment. In this article, a controllable commutation failure inhibitor (CCFI) is developed which obviates the main drawbacks of the existing power electronic based and fault current limiting based strategies. Under normal circumstances, the developed CCFI improves the steady-state stability and the power transfer capability of the inverter ac lines, while it does not cause excessive voltage stress on the converter valves. In addition, it would reduce the risk of commutation failure occurrence, since it does not lead to any voltage drop in the commutation circuit. When a fault occurs at one of the inverter ac systems, its corresponding CCFI limits the fault current depending on the reduced extinction angle. This would not only inhibit the successive commutation failures on the HVdc converter, but also extend the lifetime of components in the inverter ac systems. The practical feasibility of the developed CCFI is assessed through laboratory testing, using a real-time Opal-RT hardware prototyping platform. The obtained results indicate that the developed CCFI can reliably inhibit the commutation failures during various types of faults.

[1]  Marta Molinas,et al.  Effects and mitigation of post-fault commutation failures in line-commutated HVDC transmission system , 2009, 2009 IEEE International Symposium on Industrial Electronics.

[2]  Mehrdad Kazerani,et al.  Commutation Failure Reduction in HVDC Systems Using Adaptive Fuzzy Logic Controller , 2007, IEEE Transactions on Power Systems.

[3]  Xinzhou Dong,et al.  An Enhanced Strategy to Inhibit Commutation Failure in Line-Commutated Converters , 2020, IEEE Transactions on Industrial Electronics.

[4]  Xiao-Ping Zhang,et al.  Series Capacitor Compensated AC Filterless Flexible LCC HVDC With Enhanced Power Transfer Under Unbalanced Faults , 2019, IEEE Transactions on Power Systems.

[5]  Ling Peng,et al.  Design a Fuzzy Controller to Minimize the Effect of HVDC Commutation Failure on Power System , 2008, IEEE Transactions on Power Systems.

[6]  Yonghui Sun,et al.  Direct-Current Predictive Control Strategy for Inhibiting Commutation Failure in HVDC Converter , 2014, IEEE Transactions on Power Systems.

[7]  F. Karlecik-Maier A New Closed Loop Control Method for HVDC Transmission , 1996, IEEE Power Engineering Review.

[8]  D. Jovcic,et al.  Thyristor-Based HVDC With Forced Commutation , 2007, IEEE Transactions on Power Delivery.

[9]  Chunyi Guo,et al.  Power Component Fault Detection Method and Improved Current Order Limiter Control for Commutation Failure Mitigation in HVDC , 2015, IEEE Transactions on Power Delivery.

[10]  Chongru Liu,et al.  Start‐up and recovery method with LCC–HVDC systems participation during AC/DC system black‐starts , 2019, IET Generation, Transmission & Distribution.

[11]  Chang Liu,et al.  Probabilistic Analysis of Commutation Failure in LCC-HVDC System Considering the CFPREV and the Initial Fault Voltage Angle , 2020, IEEE Transactions on Power Delivery.

[12]  Huan Ma,et al.  A Control Strategy for Suppressing HVDC Continuous Commutation Failure Risk under Weak AC State , 2019, 2019 IEEE 3rd International Conference on Green Energy and Applications (ICGEA).

[13]  Xinzhou Dong,et al.  A Predictive Control Strategy for Mitigation of Commutation Failure in LCC-Based HVDC Systems , 2019, IEEE Transactions on Power Electronics.

[14]  J. B. Davies,et al.  Commutation failures in HVDC transmission systems , 1996 .

[15]  Lei Chen,et al.  Study on the Application of a Flux-Coupling-Type Superconducting Fault Current Limiter for Decreasing HVdc Commutation Failure , 2015, Canadian Journal of Electrical and Computer Engineering.

[16]  Qi Wang,et al.  Evaluation of Commutation failure Risk for HVDC Caused by Harmonic Voltage , 2019, 2019 IEEE 3rd Conference on Energy Internet and Energy System Integration (EI2).

[17]  Hak-Man Kim,et al.  An Algorithm for Effective Mitigation of Commutation Failure in High-Voltage Direct-Current Systems , 2016, IEEE Transactions on Power Delivery.

[18]  Jun Liang,et al.  Feasibility and Reliability Analysis of LCC DC Grids and LCC/VSC Hybrid DC Grids , 2019, IEEE Access.

[19]  Yi Sun,et al.  Study on Fault Current Suppression and Commutation Failure in Inverter Side of ±1100 kV DC System , 2018, 2018 IEEE International Conference on High Voltage Engineering and Application (ICHVE).

[20]  Xiaochun Ma,et al.  Comparison of CCC and LCC in HVDC System , 2012 .

[21]  A. Hansen,et al.  Decreasing the commutation failure frequency in HVDC transmission systems , 2000 .

[22]  Xinzhou Dong,et al.  A Fault Current Limiting Approach for Commutation Failure Prevention in LCC-HVDC Transmission Systems , 2019, IEEE Transactions on Power Delivery.

[23]  Jung-Wook Park,et al.  Effect of a SFCL on Commutation Failure in a HVDC System , 2013, IEEE Transactions on Applied Superconductivity.

[24]  N. Honjo,et al.  Fast and predictive HVDC extinction angle control , 1997 .

[25]  V. Dinavahi,et al.  Detailed modeling of CIGRE HVDC benchmark system using PSCAD/EMTDC and PSB/SIMULINK , 2006, IEEE Transactions on Power Delivery.

[26]  D. Kosterev,et al.  Design and implementation of AC voltage dependent current order limiter at Pacific HVDC Intertie , 2000 .

[27]  C. W. Taylor,et al.  HVDC controls for system dynamic performance , 1991 .

[28]  Jin Liu,et al.  Analysis of commutation failure of HVDC transmission system with wind farm , 2018, 2018 2nd IEEE Conference on Energy Internet and Energy System Integration (EI2).

[29]  Xiao-Ping Zhang,et al.  Elimination of Commutation Failures of LCC HVDC System with Controllable Capacitors , 2016, IEEE Transactions on Power Systems.

[30]  Julia Frankfurter,et al.  Reactive Power Control In Electric Systems , 2016 .