Three-Phase Shunt Active Power Filter

Active power filters have been widely used for harmonic elimination. The performance of a conventional three-phase shunt Active Power Filter (APF) using Synchronous Detection Method (SDM) has been compared with Nonlinear Autoregressive-Moving Average (NARMA)-L2 based APF. The novelty of this study lies in the application of NARMA-L2 control to generate the amplitude of the reference supply current required by the APF circuit and the successful implementation of the APF system for harmonic elimination. The entire system has been modeled using MATLAB 6.1 toolbox. Simulation results demonstrate the applicability of NARMA-L2 controller for the control of APF.

[1]  F. Blaabjerg,et al.  A dynamic voltage restorer (DVR) with selective harmonic compensation at medium voltage level , 2003, IEEE Transactions on Industry Applications.

[2]  Moleykutty George,et al.  Speed Control of Separately Excited DC Motor , 2008 .

[3]  L. Protin,et al.  On the detection of load active currents for active filter control , 1996 .

[4]  R. Faranda,et al.  UPQC compensation strategy and design aimed at reducing losses , 2002, Industrial Electronics, 2002. ISIE 2002. Proceedings of the 2002 IEEE International Symposium on.

[5]  Shyh-Jier Huang,et al.  A control algorithm for three-phase three-wired active power filters under nonideal mains voltages , 1999 .

[6]  F. Blaabjerg,et al.  A detailed comparison of system topologies for dynamic voltage restorers , 2005, IEEE Transactions on Industry Applications.

[7]  D. J. Adams,et al.  Harmonic and reactive power compensation based on the generalized instantaneous reactive power theory for three-phase four-wire systems , 1998 .

[8]  A. Elnady,et al.  New functionalities of the unified power quality conditioner , 2001, 2001 IEEE/PES Transmission and Distribution Conference and Exposition. Developing New Perspectives (Cat. No.01CH37294).

[9]  Kamal Al-Haddad,et al.  An improved control algorithm of shunt active filter for voltage regulation, harmonic elimination, power-factor correction, and balancing of nonlinear loads , 2000 .

[10]  Hirofumi Akagi,et al.  Trends in active power line conditioners , 1992, Proceedings of the 1992 International Conference on Industrial Electronics, Control, Instrumentation, and Automation.

[11]  F. Blaabjerg,et al.  Control and testing of a dynamic voltage restorer (DVR) at medium voltage level , 2003, IEEE 34th Annual Conference on Power Electronics Specialist, 2003. PESC '03..

[12]  Xu Dianguo,et al.  Unified power quality conditioner (UPQC): the principle, control and application , 2002, Proceedings of the Power Conversion Conference-Osaka 2002 (Cat. No.02TH8579).

[13]  Arindam Ghosh,et al.  A unified power quality conditioner (UPQC) for simultaneous voltage and current compensation , 2001 .

[14]  Seung-Ki Sul,et al.  A calculation for the compensation voltages in dynamic voltage restorers by use of PQR power theory , 2004, Nineteenth Annual IEEE Applied Power Electronics Conference and Exposition, 2004. APEC '04..

[15]  Leon M. Tolbert,et al.  A multilevel converter-based universal power conditioner , 1999, 30th Annual IEEE Power Electronics Specialists Conference. Record. (Cat. No.99CH36321).

[16]  D.M. Vilathgamuwa,et al.  Analysis of series compensation and DC-link voltage controls of a transformerless self-charging dynamic voltage restorer , 2004, IEEE Transactions on Power Delivery.

[17]  G. K. Dubey,et al.  An instantaneous reactive volt-ampere compensator and harmonic suppressor system , 1999 .

[18]  F. Blaabjerg,et al.  Control and testing of a dynamic voltage restorer (DVR) at medium voltage level , 2003, IEEE Transactions on Power Electronics.

[19]  Hirofumi Akagi,et al.  The unified power quality conditioner: the integration of series- and shunt-active filters , 1998 .

[20]  J. Nastran,et al.  Active power filter for nonlinear AC loads , 1994 .

[21]  Mauricio Aredes,et al.  Three-phase four-wire shunt active filter control strategies , 1997 .

[22]  Moleykutty George Artificial Intelligence Based Three-Phase Unified Power Quality Conditioner , 2007 .

[23]  Po-Tai Cheng,et al.  Line harmonics reduction in high-power systems using square-wave inverters-based dominant harmonic active filter , 1999 .