Sub-ångstro¨m structure characterisation: the Brite-Euram route towards one ångstro¨m

Abstract Rather than pushing the point resolution of the electron microscope below 1A˚by increasing the voltage above 1 MeV, we have adopted a different route in which we push down the information limit and retrieve the information by image processing. This goal has now been achieved by using a coherent electron source and optimizing the lens design and the detector configuration and the alignment procedure. The phase is recovered by two different holographic methods: sideband holography and focus variation, whereas for the object structure retrieval, a new method has been developed to “reverse” in a sense the dynamical scattering in the object.

[1]  H. Lichte,et al.  High-resolution electron holography of non-periodic structures at the example of a Σ = 13 grain boundary in gold , 1996 .

[2]  Hannes Lichte,et al.  Optimum focus for taking electron holograms , 1991 .

[3]  D. Van Dyck,et al.  A new approach to object wavefunction reconstruction in electron microscopy , 1993 .

[4]  Janssen,et al.  Phase retrieval through focus variation for ultra-resolution in field-emission transmission electron microscopy. , 1992, Physical review letters.

[5]  D. Gabor A New Microscopic Principle , 1948, Nature.

[6]  D. Dyck,et al.  Wave function reconstruction in HRTEM: the parabola method , 1996 .

[7]  H. Lichte,et al.  0.1 nm information limit with the CM30FEG-special Tübingen , 1993 .

[8]  K. Herrmann,et al.  Performance of electron image converters with YAG single-crystal screen and CCD sensor , 1991 .

[9]  Hannes Lichte,et al.  The phase-shift method in electron-off-axis holography: using neural network techniques , 1996 .

[10]  M. Lehmann,et al.  Artefacts in electron holography , 1996 .

[11]  Orchowski,et al.  Electron holography surmounts resolution limit of electron microscopy. , 1995, Physical review letters.

[12]  H. Lichte Electron holography: optimum position of the biprism in the electron microscope , 1996 .

[13]  A. H. Buist,et al.  Optimal experimental design for exit wave reconstruction from focal series in TEM , 1996 .

[14]  H. Lichte,et al.  Holographic measurement of the wave aberration of an electron microscope by means of the phases in the Fourier spectrum , 1995 .

[15]  D. Van Dyck,et al.  Ultimate resolution and information in electron microscopy II. The information limit of transmission electron microscopes , 1993 .

[16]  K. Herrmann,et al.  Development and performance of a fast fibre-plate coupled CCD camera at medium energy and image processing system for electron holography , 1996 .

[17]  H. Lichte Electron holography: I. Can electron holography reach 0.1 nm resolution? , 1992 .

[18]  M. Lehmann,et al.  Reconstruction of electron off-axis holograms: a new and fast alternative method , 1994 .

[19]  Fu,et al.  Correction of aberrations of an electron microscope by means of electron holography. , 1991, Physical review letters.

[20]  D. Van Dyck,et al.  Ultimate resolution and information in electron microscopy: general principles , 1992 .