Experimental study on the fire resistance of RC beams strengthened with near-surface-mounted high-Tg BFRP bars

A lack of knowledge regarding the fire resistance of fiber reinforced polymer (FRP) reinforced/strengthened concrete structures has impeded the wide acceptance and use of these materials. This paper presents the results of both mechanical property tests performed on basalt FRP (BFRP) bars during and after exposure to high temperatures and the fire resistance of reinforced concrete (RC) beams strengthened with near-surface-mounted (NSM) high-Tg BFRP bars. Experiments were conducted on 108 effective tensile test specimens and 7 four-point bending beam specimens. The results indicate that a resin matrix with a higher Tg value and good compatibility after pultrusion curing process with fiber were very useful for improving the heat resistance of FRP bars, meaning that NSM FRP strengthened RC beams could exhibit improved fire resistance. The FRP bars maintained sufficient anchorage if only two ends of the NSM FRP bar were protected against fire by stretching them into supporting components or wrapping them with U-shaped fire protection boards. The NSM high-Tg FRP strengthened RC beams could potentially exhibit the same level of fire resistance as the RC beams. These preliminary conclusions improve the prospects of using FRP materials in engineering applications.

[1]  Mark F. Green,et al.  Fire insulation schemes for FRP-strengthened concrete slabs , 2006 .

[2]  David Hui,et al.  A critical review on nanotube and nanotube/nanoclay related polymer composite materials , 2006 .

[3]  Matthew B. Blaschko,et al.  Externally bonded FRP reinforcement for RC structures , 2001 .

[4]  A. Shimizu,et al.  Tensile Strength of Continuous Fiber Bar Under High Temperature , 1993, SP-138: Fiber-Reinforced-Plastic Reinforcement for Concrete Structures - International Symposium.

[5]  Xin Wang,et al.  Tensile Properties of CFRP and Hybrid FRP Composites at Elevated Temperatures , 2009 .

[6]  E. Kandare,et al.  Fire reaction properties of flax/epoxy laminates and their balsa-core sandwich composites with or without fire protection , 2014 .

[7]  Zhishen Wu,et al.  Structural Performance of RC Beams Strengthened with Prestressed Near-Surface-Mounted CFRP Tendons , 2007, SP-245: Case Histories and Use of FRP for Prestressing Applications.

[8]  D. Hui,et al.  Influence of mesoporous fillers with PP-g-MA on flammability and tensile behavior of polypropylene composites , 2013 .

[9]  Stephanie L. Walkup,et al.  Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete Structures (ACI 440.2R-02) , 2005 .

[10]  Ershad U. Chowdhury,et al.  Fire Performance of FRP Systems for Infrastructure: A State-of-the-Art Report , 2005 .

[11]  D. Hui,et al.  Fire retardancy of clay/carbon nanofiber hybrid sheet in fiber reinforced polymer composites , 2009 .

[12]  David Hui,et al.  Creep rupture of a GFRP composite at elevated temperatures , 2000 .

[13]  Luc Taerwe,et al.  Experimental investigation on fire endurance of insulated concrete beams strengthened with near surface mounted FRP bar reinforcement , 2012 .

[14]  Stefanie Feih,et al.  Thermal–mechanical modelling of laminates with fire protection coating , 2013 .

[15]  D. Hui,et al.  Mechanical, electrical and thermal properties of aligned carbon nanotube/polyimide composites , 2014 .

[16]  B. Kandola,et al.  Mechanical performance of heat/fire damaged novel flame retardant glass - reinforced epoxy composites , 2003 .

[17]  L. Lorenzis,et al.  Near-surface mounted FRP reinforcement: An emerging technique for strengthening structures , 2007 .

[18]  Emidio Nigro,et al.  Bond behavior of FRP NSM systems in concrete elements , 2012 .

[19]  L. Taerwe,et al.  Fire tests on concrete beams strengthened with fibre composite laminates. , 2000 .

[20]  A. Prota,et al.  Tensile behavior of epoxy based FRP composites under extreme service conditions , 2012 .

[21]  M. Green,et al.  Effects of elevated temperature on near surface mounted and externally bonded FRP strengthening systems for concrete , 2013 .

[22]  Cecilia Abecassis Empis,et al.  The Dalmarnock Fire Tests : Experiments and Modelling , 2008 .

[23]  S. Rizkalla,et al.  INVESTIGATION OF BOND IN CONCRETE STRUCTURES STRENGTHENED WITH NEAR SURFACE MOUNTED CARBON FIBER REINFORCED POLYMER STRIPS , 2003 .

[24]  H Wong,et al.  An Experimental Study of the Mechanical Properties of Fibre Reinforced Polymer (FRP) and Steel Reinforcing Bars at Elevated Temperatures , 2007 .

[25]  Luc Taerwe,et al.  Properties of Fiber Reinforced Plastics at Elevated Temperatures with Regard to Fire Resistance of Reinforced Concrete Members , 1999, SP-188: 4th Intl Symposium - Fiber Reinforced Polymer Reinforcement for Reinforced Concrete Structures.

[26]  Mark F. Green,et al.  Preliminary Guidance for the Design of FRP-strengthened Concrete Members Exposed to Fire: , 2007 .

[27]  V. Bianco,et al.  Design formula to evaluate the NSM FRP strips shear strength contribution to a RC beam , 2014 .

[28]  Soo-Yeon Seo,et al.  Bond strength of near surface-mounted FRP plate for retrofit of concrete structures , 2013 .

[29]  Mohamed Saafi,et al.  Effect of fire on FRP reinforced concrete members , 2002 .