In Vivo Bone Response to Biomechanical Loading at the Bone/Dental-Implant Interface

Since dental implants must withstand relatively large forces and moments in function, a better understanding of in vivo bone response to loading would aid implant design. The following topics are essential in this problem. (1) Theoretical models and experimental data are available for understanding implant loading as an aid to case planning. (2) At least for several months after surgery, bone healing in gaps between implant and bone as well as in pre-existing damaged bone will determine interface structure and properties. The ongoing healing creates a complicated environment. (3) Recent studies reveal that an interfacial cement line exists between the implant surface and bone for titanium and hydroxyapatite (HA). Since cement lines in normal bone have been identified as weak interfaces, a cement line at a bone-biomaterial interface may also be a weak point. Indeed, data on interfacial shear and tensile "bond" strengths are consistent with this idea. (4) Excessive interfacial micromotion early after implantation interferes with local bone healing and predisposes to a fibrous tissue interface instead of osseointegration. (5) Large strains can damage bone. For implants that have healed in situ for several months before being loaded, data support the hypothesis that interfacial overload occurs if the strains are excessive in interfacial bone. While bone "adaptation" to loading is a long-standing concept in bone physiology, researchers may sometimes be too willing to accept this paradigm as an exclusive explanation of in vivo tissue responses during experiments, while overlooking confounding variables, alternative (non-mechanical) explanations, and the possibility that different types of bone (e.g., woven bone, Haversian bone, plexiform bone) may have different sensitivities to loading under healing vs. quiescent conditions.

[1]  A biomechanical study of osseointegration. In-vivo measurements in rat, rabbit, dog and man , 1996 .

[2]  D B Burr,et al.  Composition of the cement line and its possible mechanical role as a local interface in human compact bone. , 1988, Journal of biomechanics.

[3]  G D Stafford,et al.  On clinical loading of osseointegrated implants. A methodological and clinical study. , 1993, Clinical oral implants research.

[4]  J. Davies,et al.  The Bone-Biomaterial Interface for Load-Bearing Implants , 1991 .

[5]  T. van Eijden Three-dimensional analyses of human bite-force magnitude and moment. , 1991, Archives of oral biology.

[6]  G. Cochran,et al.  The Influence of Biomechanical Factors at the Tissue-Biomaterial Interface , 1987 .

[7]  F. Isidor,et al.  Loss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeys. , 1996, Clinical oral implants research.

[8]  D. Carter,et al.  Cyclic mechanical property degradation during fatigue loading of cortical bone. , 1996, Journal of biomechanics.

[9]  J. W. Osborn,et al.  A thin bite-force transducer with three-dimensional capabilities reveals a consistent change in bite-force direction during human jaw-muscle endurance tests. , 1993, Archives of oral biology.

[10]  J. Bertram,et al.  THE ‘LAW OF BONE TRANSFORMATION’: A CASE OF CRYING WOLFF? , 1991, Biological reviews of the Cambridge Philosophical Society.

[11]  P. Glantz,et al.  Vertical load distribution on a three-unit prosthesis supported by a natural tooth and a single Brånemark implant. An in vivo study. , 1995, Clinical oral implants research.

[12]  G A Niznick,et al.  Bending overload and implant fracture: a retrospective clinical analysis. , 1996, The International journal of oral & maxillofacial implants.

[13]  W. Roggendorf,et al.  Biomechanical and Morphometric Testing Methods for Porous and Surface-Reactive Biomaterials , 1987 .

[14]  W. Roberts,et al.  Microhardness and anisotropy of the vital osseous interface and endosseous implant supporting bone , 1998, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[15]  Peter Zioupos,et al.  The extent of microcracking and the morphology of microcracks in damaged bone , 1994, Journal of Materials Science.

[16]  T. Yamamuro,et al.  A new glass-ceramic for bone replacement: evaluation of its bonding to bone tissue. , 1985, Journal of biomedical materials research.

[17]  David B. Burr,et al.  Structure, Function, and Adaptation of Compact Bone , 1989 .

[18]  T. Keaveny,et al.  Dependence of trabecular damage on mechanical strain , 1997, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[19]  J. Galante,et al.  ESB Research Award 1992. The mechanism of bone remodeling and resorption around press-fitted THA stems. , 1993, Journal of biomechanics.

[20]  D. Griffin,et al.  Finite-Element Analysis , 1975 .

[21]  C. Bünger,et al.  Hydroxyapatite coating converts fibrous tissue to bone around loaded implants. , 1993, The Journal of bone and joint surgery. British volume.

[22]  K. de Groot,et al.  Tensile strength of the interface between hydroxyapatite and bone. , 1992, Journal of biomedical materials research.

[23]  H Vaillancourt,et al.  Finite element analysis of crestal bone loss around porous-coated dental implants. , 1995, Journal of applied biomaterials : an official journal of the Society for Biomaterials.

[24]  Frost Hm,et al.  The mechanostat: a proposed pathogenic mechanism of osteoporoses and the bone mass effects of mechanical and nonmechanical agents. , 1987 .

[25]  W E Roberts,et al.  Bone tissue interface. , 1988, Journal of dental education.

[26]  J. B. Brunski,et al.  36. Influence of Biomechanical Factors at the Bone-Biomaterial Interface , 1991 .

[27]  G. Rodan,et al.  Osteopenia in the immobilized rat hind limb is associated with increased bone resorption and decreased bone formation. , 1989, Bone.

[28]  C. J. McGrath,et al.  Effect of exchange rate return on volatility spill-over across trading regions , 2012 .

[29]  Daniel Buser,et al.  Guided bone regeneration in implant dentistry , 1994 .

[30]  P. Aspenberg,et al.  Tensile bond between bone and titanium: a reappraisal of osseointegration. , 1998, Acta orthopaedica Scandinavica.

[31]  P. Fielder,et al.  Implants: Bone physiology and metabolism. , 1987, CDA journal.

[32]  T. V. Eijden Three-dimensional analyses of human bite-force magnitude and moment. , 1991 .

[33]  I Herrmann,et al.  Osseointegrated implants for treatment of partially edentulous jaws: A 5 year prospective multicentre study , 1994 .

[34]  K Miller,et al.  Biomechanics of soft tissues. , 2000, Medical science monitor : international medical journal of experimental and clinical research.

[35]  R Skalak,et al.  Biomechanical considerations in osseointegrated prostheses. , 1983, The Journal of prosthetic dentistry.

[36]  C. Rubin,et al.  Biologic Modulation of Mechanical Influences in Bone Remodeling , 1990 .

[37]  George A. Zarb,et al.  Introduction to osseointegration in clinical dentistry , 1983 .

[38]  A. Asundi,et al.  Biomechanics of endodontic endosseous implants--a comparative photoelastic evaluation. , 1999, Endodontics & dental traumatology.

[39]  G. Wolfinger,et al.  IMMEDIATE LOADING OF BRÅNEMARK IMPLANTS IN EDENTULOUS MANDIBLES: A PRELIMINARY REPORT , 1997, Implant dentistry.

[40]  D B Burr,et al.  Increased intracortical remodeling following fatigue damage. , 1993, Bone.

[41]  R. Mericske-Stern Three-dimensional force measurements with mandibular overdentures connected to implants by ball-shaped retentive anchors. A clinical study. , 1998, The International journal of oral & maxillofacial implants.

[42]  D van Steenberghe,et al.  Fixture design and overload influence marginal bone loss and fixture success in the Brånemark system. , 1992, Clinical oral implants research.

[43]  S A Goldstein,et al.  A comparison of the fatigue behavior of human trabecular and cortical bone tissue. , 1992, Journal of biomechanics.

[44]  R M Pilliar,et al.  Dental implant design--effect on bone remodeling. , 1991, Journal of biomedical materials research.

[45]  H. Schliephake,et al.  Evaluation of bone healing in patients with bone grafts and endosseous implants using single photon emission tomography (SPECT). , 1998, Clinical Oral Implants Research.

[46]  P. Thomsen,et al.  Tissue response to titanium implants in experimental antigen-induced arthritis. , 1993, Biomaterials.

[47]  P J Prendergast,et al.  Biophysical stimuli on cells during tissue differentiation at implant interfaces , 1997 .

[48]  J. Davies,et al.  Mechanisms of endosseous integration. , 1998, The International journal of prosthodontics.

[49]  H. Frost,et al.  The mechanostat: a proposed pathogenic mechanism of osteoporoses and the bone mass effects of mechanical and nonmechanical agents. , 1987, Bone and mineral.

[50]  D. Buser,et al.  Healing pattern of bone regeneration in membrane-protected defects: a histologic study in the canine mandible. , 1994, The International journal of oral & maxillofacial implants.

[51]  R Adell,et al.  [Osseointegrated implants]. , 1987, Tandlaegebladet.

[52]  E. Richter,et al.  In vivo horizontal bending moments on implants. , 1998, The International journal of oral & maxillofacial implants.

[53]  O. Miyakawa,et al.  Influence of restoration type on stress distribution in bone around implants: a three-dimensional finite element analysis. , 1998, The International journal of oral & maxillofacial implants.

[54]  M. McKee,et al.  Immunocytochemical and Lectin-Gold Characterization of the Interface Between Alveolar Bone and Implanted Hydroxyapatite in the Rat , 1993 .

[55]  K. Berhane,et al.  Predictable crestal bone remodelling around two porous-coated titanium alloy dental implant designs. A radiographic study in dogs. , 1994, Clinical oral implants research.

[56]  W C Hayes,et al.  Compact bone fatigue damage: a microscopic examination. , 1977, Clinical orthopaedics and related research.

[57]  John D. Currey,et al.  The Mechanical Adaptations of Bones , 1984 .

[58]  J B Brunski,et al.  Mechanical and morphologic investigation of the tensile strength of a bone-hydroxyapatite interface. , 1997, Journal of biomedical materials research.

[59]  M. McKee,et al.  Ultrastructural, Cytochemical, and Immunocytochemical Studies on Bone and its Interfaces , 1993 .

[60]  S. Szmukler‐Moncler,et al.  Timing of loading and effect of micromotion on bone-dental implant interface: review of experimental literature. , 1998, Journal of biomedical materials research.

[61]  B. Martin,et al.  Mathematical model for repair of fatigue damage and stress fracture in osteonal bone , 1995, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[62]  C. Bünger,et al.  Tissue ingrowth into titanium and hydroxyapatite‐coated implants during stable and unstable mechanical conditions , 1992, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[63]  C. Bünger,et al.  Hydroxyapatite coating modifies implant membrane formation. Controlled micromotion studied in dogs. , 1992, Acta orthopaedica Scandinavica.

[64]  Richter Ej,et al.  In vivo horizontal bending moments on implants. , 1998 .

[65]  P A Schnitman,et al.  Immediate fixed interim prostheses supported by two-stage threaded implants: methodology and results. , 1990, The Journal of oral implantology.

[66]  R. Pilliar,et al.  34. Quantitative Evaluation of the Effect of Movement at a Porous Coated Implant-Bone Interface , 1991 .

[67]  D. Burr,et al.  Bone Microdamage and Skeletal Fragility in Osteoporotic and Stress Fractures , 1997, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[68]  H. Frost The regional acceleratory phenomenon: a review. , 1983, Henry Ford Hospital medical journal.

[69]  H Vaillancourt,et al.  Factors affecting crestal bone loss with dental implants partially covered with a porous coating: a finite element analysis. , 1996, The International journal of oral & maxillofacial implants.

[70]  K. Higuchi,et al.  The use of titanium fixtures for intraoral anchorage to facilitate orthodontic tooth movement. , 1992, The International journal of oral & maxillofacial implants.

[71]  J. Davies,et al.  In vitro modeling of the bone/implant interface , 1996, The Anatomical record.

[72]  W. Panje,et al.  The use of percutaneous implants for the prosthetic rehabilitation of orbital defects in irradiated cancer patients: a report of clinical outcomes and complications. , 1998, The International journal of oral & maxillofacial implants.

[73]  E. Hunziker,et al.  Effect of surface topology on the osseointegration of implant materials in trabecular bone. , 1995, Journal of biomedical materials research.

[74]  M. Yoshinari,et al.  An immunoelectron microscopic localization of noncollagenous bone proteins (osteocalcin and osteopontin) at the bone-titanium interface of rat tibiae. , 1998, Journal of biomedical materials research.