Tele-impedance based assistive control for a compliant knee exoskeleton

This paper presents a tele-impedance based assistive control scheme for a knee exoskeleton device. The proposed controller captures the user's intent to generate task-related assistive torques by means of the exoskeleton in different phases of the subject's normal activity. To do so, a detailed musculoskeletal model of the human knee is developed and experimentally calibrated to best match the user's kinematic and dynamic behavior. Three dominant antagonistic muscle pairs are used in our model, in which electromyography (EMG) signals are acquired, processed and used for the estimation of the knee joint torque, trajectory and the stiffness trend, in real time. The estimated stiffness trend is then scaled and mapped to a task-related stiffness interval to agree with the desired degree of assistance. The desired stiffness and equilibrium trajectories are then tracked by the exoskeleton's impedance controller. As a consequence, while minimum muscular activity corresponds to low stiffness, i.e.?highly transparent motion, higher co-contractions result in a stiffer joint and a greater level of assistance. To evaluate the robustness of the proposed technique, a study of the dynamics of the human-exoskeleton system is conducted, while the stability in the steady state and transient condition is investigated. In addition, experimental results of standing-up and sitting-down tasks are demonstrated to further investigate the capabilities of the controller. The results indicate that the compliant knee exoskeleton, incorporating the proposed tele-impedance controller, can effectively generate assistive actions that are volitionally and intuitively controlled by the user's muscle activity. We propose a tele-impedance based assistive control for a knee exoskeleton.An EMG-driven biomechanical model estimates the net torque and joint stiffness trend index.The outputs of the model are used to derive the trajectory and stiffness of the exoskeleton's impedance controller.The exoskeleton can generate assistive actions that are volitionally controlled by the user's muscle activity.

[1]  Alexandre Trofino,et al.  Biquadratic stability of uncertain linear systems , 2001, IEEE Trans. Autom. Control..

[2]  Ulrich Konigorski,et al.  Observer Based Method for Joint Torque Estimation in Active Orthoses , 2012 .

[3]  Hyunglae Lee,et al.  Investigation of human ankle mechanical impedance during locomotion using a wearable ankle robot , 2013, 2013 IEEE International Conference on Robotics and Automation.

[4]  M. Munih,et al.  Analysis of standing up and sitting down in humans: definitions and normative data presentation. , 1990, Journal of biomechanics.

[5]  A. Hill The heat of shortening and the dynamic constants of muscle , 1938 .

[6]  Carlo J. De Luca,et al.  The Use of Surface Electromyography in Biomechanics , 1997 .

[7]  Frans C. T. van der Helm,et al.  A Series Elastic- and Bowden-Cable-Based Actuation System for Use as Torque Actuator in Exoskeleton-Type Robots , 2006, Int. J. Robotics Res..

[8]  M. Bobbert,et al.  Length and moment arm of human leg muscles as a function of knee and hip-joint angles , 2004, European Journal of Applied Physiology and Occupational Physiology.

[9]  Nikolaos G. Tsagarakis,et al.  Tele-impedance: Teleoperation with impedance regulation using a body–machine interface , 2012, Int. J. Robotics Res..

[10]  Giorgio Grioli,et al.  VSA-II: a novel prototype of variable stiffness actuator for safe and performing robots interacting with humans , 2008, 2008 IEEE International Conference on Robotics and Automation.

[11]  Pyung Hun Chang,et al.  Stochastic estimation of human arm impedance under nonlinear friction in robot joints: A model study , 2009, Journal of Neuroscience Methods.

[12]  Neville Hogan,et al.  Impedance Control: An Approach to Manipulation: Part III—Applications , 1985 .

[13]  Bram Vanderborght,et al.  An exoskeleton for gait rehabilitation: Prototype design and control principle , 2008, 2008 IEEE International Conference on Robotics and Automation.

[14]  Hugh Herr,et al.  Agonist-antagonist active knee prosthesis: a preliminary study in level-ground walking. , 2009, Journal of rehabilitation research and development.

[15]  Nikolaos G. Tsagarakis,et al.  Tele-impedance: Towards transferring human impedance regulation skills to robots , 2012, 2012 IEEE International Conference on Robotics and Automation.

[16]  Homayoon Kazerooni,et al.  That Which Does Not Stabilize, Will Only Make Us Stronger , 2007, Int. J. Robotics Res..

[17]  F. Zajac Muscle and tendon: properties, models, scaling, and application to biomechanics and motor control. , 1989, Critical reviews in biomedical engineering.

[18]  Nikos G. Tsagarakis,et al.  A Novel Actuator with Reconfigurable Stiffness for a Knee Exoskeleton: Design and Modeling , 2012 .

[19]  Shahid Hussain,et al.  Adaptive Impedance Control of a Robotic Orthosis for Gait Rehabilitation , 2013, IEEE Transactions on Cybernetics.

[20]  Ronald J. Triolo,et al.  A Variable Impedance Knee Mechanism for Controlled Stance Flexion During Pathological Gait , 2012, IEEE/ASME Transactions on Mechatronics.

[21]  Enrico Pagello,et al.  Modeling the Human Knee for Assistive Technologies , 2012, IEEE Transactions on Biomedical Engineering.

[22]  Nicola Vitiello,et al.  NEUROExos: A Powered Elbow Exoskeleton for Physical Rehabilitation , 2013, IEEE Transactions on Robotics.

[23]  Günter Hommel,et al.  A Human--Exoskeleton Interface Utilizing Electromyography , 2008, IEEE Transactions on Robotics.

[24]  Yoshiyuki Sankai,et al.  Power assist control for walking aid with HAL-3 based on EMG and impedance adjustment around knee joint , 2002, IEEE/RSJ International Conference on Intelligent Robots and Systems.

[25]  Rieko Osu,et al.  Short- and long-term changes in joint co-contraction associated with motor learning as revealed from surface EMG. , 2002, Journal of neurophysiology.

[26]  M. Goldfarb,et al.  Preliminary Evaluation of a Powered Lower Limb Orthosis to Aid Walking in Paraplegic Individuals , 2011, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[27]  Giorgio C. Buttazzo,et al.  Design of a variable impedance differential actuator for wearable robotics applications , 2010, 2010 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[28]  Nicola Vitiello,et al.  NEUROExos: A variable impedance powered elbow exoskeleton , 2011, 2011 IEEE International Conference on Robotics and Automation.

[29]  Kyoungchul Kong,et al.  Design and control of an exoskeleton for the elderly and patients , 2006, IEEE/ASME Transactions on Mechatronics.

[30]  David G Lloyd,et al.  Neuromusculoskeletal modeling: estimation of muscle forces and joint moments and movements from measurements of neural command. , 2004, Journal of applied biomechanics.

[31]  Antonio Bicchi,et al.  Optimality principles in stiffness control: The VSA kick , 2012, 2012 IEEE International Conference on Robotics and Automation.

[32]  H. Goldstein,et al.  The rise of the body bots [robotic exoskeletons] , 2005, IEEE Spectrum.

[33]  D. A. Shreeve,et al.  An evaluation of optimization techniques for the prediction of muscle activation patterns during isometric tasks. , 1996, Journal of biomechanical engineering.

[34]  H. Herr,et al.  Adaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait , 2004, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[35]  Vojtech Veselý,et al.  Robust stability conditions for polytopic systems , 2005, Int. J. Syst. Sci..

[36]  Yasuhisa Hasegawa,et al.  Sit-to-Stand and Stand-to-Sit Transfer Support for Complete Paraplegic Patients with Robot Suit HAL , 2010, Adv. Robotics.

[37]  W. Rymer,et al.  In vivo human knee joint dynamic properties as functions of muscle contraction and joint position. , 1997, Journal of biomechanics.

[38]  H. van der Kooij,et al.  Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation , 2007, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[39]  Yacine Amirat,et al.  EMG based approach for wearer-centered control of a knee joint actuated orthosis , 2013, 2013 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[40]  R. Riener,et al.  Patient-cooperative strategies for robot-aided treadmill training: first experimental results , 2005, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[41]  P A Huijing,et al.  Important experimental factors for skeletal muscle modelling: non-linear changes of muscle length force characteristics as a function of degree of activity. , 1996, European journal of morphology.

[42]  Nicola Vitiello,et al.  Intention-Based EMG Control for Powered Exoskeletons , 2012, IEEE Transactions on Biomedical Engineering.

[43]  D. Lloyd,et al.  An EMG-driven musculoskeletal model to estimate muscle forces and knee joint moments in vivo. , 2003, Journal of biomechanics.

[44]  D. G. Caldwell,et al.  Design, modeling and control of a series elastic actuator for an assistive knee exoskeleton , 2012, 2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob).

[45]  Nikolaos G. Tsagarakis,et al.  Tele-Impedance based stiffness and motion augmentation for a knee exoskeleton device , 2013, 2013 IEEE International Conference on Robotics and Automation.

[46]  Emilio Bizzi,et al.  Combinations of muscle synergies in the construction of a natural motor behavior , 2003, Nature Neuroscience.

[47]  Jerry E. Pratt,et al.  The RoboKnee: an exoskeleton for enhancing strength and endurance during walking , 2004, IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004.

[48]  Matthew M. Williamson,et al.  Series elastic actuators , 1995, Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots.

[49]  K N An,et al.  Determination of muscle orientations and moment arms. , 1984, Journal of biomechanical engineering.