Label-free single cell analysis with a chip-based impedance flow cytometer

For description of cellular phenotypes and physiological states new developments are needed. Axetris' impedance flow cytometer (IFC) (Leister) is a new promising label-free alternative to fluorescence-based flow cytometry (FCM). IFC measures single cells at various frequencies simultaneously. The frequencies used for signal acquisition range from 0.1 to 20 MHz. The impedance signal provides information about cell volume (< 1 MHz), membrane capacitance (~1-4 MHz) and cytoplasmic conductivity (4-10 MHz), parameters directly related to the physiological conditions of single cells. In MCF-7 cell viability experiments, cells were treated with cytotoxic agents to induce cell death. Impedance analysis showed discrimination between viable and dead cells. This was clearly visible at 4 MHz suggesting that differentiation was possible based on cell membrane capacitance. Changes in cell membrane potential were also analysed by IFC. RN22 cells were loaded with membrane potential sensitive dye (DiBAC4). The cells were then treated with the ionophore valinomycin. Changes in membrane potential were detectable at the level of cytoplasm conductivity (>4 MHz) and membrane capacitance (1-4 MHz). Our data indicate that IFC can be a valuable alternative to conventional FCM for various applications in the field of cell death and physiology. The work will be extended to address further potential applications of IFC in biotechnology and biomedical cell analysis, as well as in cell sorting.

[1]  S. Mentzer,et al.  Hierarchical clustering of monoclonal antibody reactivity patterns in nonhuman species , 2009, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[2]  Christian H. Reccius,et al.  Leukocyte analysis and differentiation using high speed microfluidic single cell impedance cytometry. , 2009, Lab on a chip.

[3]  A. Stenzl,et al.  Expansion and differentiation of neural progenitors derived from the human adult enteric nervous system. , 2009, Gastroenterology.

[4]  Hywel Morgan,et al.  Bead-based immunoassays using a micro-chip flow cytometer. , 2007, Lab on a chip.

[5]  Leif O. Brown,et al.  A flow cytometer for the measurement of Raman spectra , 2008, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[6]  Hywel Morgan,et al.  Impedance spectroscopy using maximum length sequences: application to single cell analysis. , 2007, The Review of scientific instruments.

[7]  John P Nolan,et al.  Spectral measurements of large particles by flow cytometry , 2009, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[8]  Thomas Braschler,et al.  Label-free detection of Babesia bovis infected red blood cells using impedance spectroscopy on a microfabricated flow cytometer. , 2007, Acta tropica.

[9]  Ruili Huang,et al.  Compound Cytotoxicity Profiling Using Quantitative High-Throughput Screening , 2007, Environmental health perspectives.

[10]  Edmund Koch,et al.  Rapid and label‐free classification of human glioma cells by infrared spectroscopic imaging , 2008, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[11]  S. Gawad,et al.  Impedance spectroscopy flow cytometry: On‐chip label‐free cell differentiation , 2005, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[12]  Helmut E Meyer,et al.  Approaching clinical proteomics: Current state and future fields of application in cellular proteomics , 2009, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[13]  Xiaoxiang Zheng,et al.  Dynamic monitoring of changes in endothelial cell-substrate adhesiveness during leukocyte adhesion by microelectrical impedance assay. , 2009, Acta biochimica et biophysica Sinica.

[14]  A. Robitzki,et al.  An impedimetric microelectrode-based array sensor for label-free detection of tau hyperphosphorylation in human cells. , 2009, Lab on a chip.

[15]  James H Jett,et al.  Raman spectroscopy comes to flow cytometry , 2008, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[16]  J. Popp,et al.  Vibrational spectroscopy—A powerful tool for the rapid identification of microbial cells at the single‐cell level , 2009, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[17]  M. Roederer How many events is enough? Are you positive? , 2008, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[18]  John Ferbas,et al.  Mixture modeling approach to flow cytometry data , 2008, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[19]  Helmut E Meyer,et al.  Approaching clinical proteomics: current state and future fields of application in fluid proteomics , 2009, Clinical chemistry and laboratory medicine.

[20]  H Morgan,et al.  Discrimination and analysis of phytoplankton using a microfluidic cytometer. , 2007, IET nanobiotechnology.

[21]  Rachel J Errington,et al.  Cytomics and cellular informatics--coping with asymmetry and heterogeneity in biological systems. , 2009, Drug discovery today.

[22]  K. L. Brown,et al.  Differentiation of alloreactive versus CD3/CD28 stimulated T‐lymphocytes using Raman spectroscopy: A greater specificity for noninvasive acute renal allograft rejection detection , 2009, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[23]  Andreas Thiel,et al.  From transcriptome to cytome: Integrating cytometric profiling, multivariate cluster, and prediction analyses for a phenotypical classification of inflammatory diseases , 2008, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[24]  A. Huwiler,et al.  On‐chip non‐invasive and label‐free cell discrimination by impedance spectroscopy , 2008, Cell proliferation.

[25]  Valery V Tuchin,et al.  In vivo multispectral, multiparameter, photoacoustic lymph flow cytometry with natural cell focusing, label‐free detection and multicolor nanoparticle probes , 2008, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[26]  Qiong Gao,et al.  Resources for integrative systems biology: from data through databases to networks and dynamic system models , 2006, Briefings Bioinform..

[27]  Urban Seger,et al.  Dielectric spectroscopy in a micromachined flow cytometer: theoretical and practical considerations. , 2004, Lab on a chip.

[28]  Erik Lindsley,et al.  In vivo cytometry: A spectrum of possibilities , 2006, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[29]  Jing Zhang,et al.  Development and validation of flow cytometric measurement for parasitemia in cultures of P. falciparum vitally stained with YOYO‐1 , 2007, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[30]  Oliver Pänke,et al.  A microelectrode-based sensor for label-free in vitro detection of ischemic effects on cardiomyocytes. , 2009, Biosensors & bioelectronics.

[31]  Xiao Xu,et al.  The application of cell‐based label‐free technology in drug discovery , 2008, Biotechnology journal.

[32]  M. Schmidt,et al.  Real-time measurement of PMA-induced cellular alterations by microelectrode array-based impedance spectroscopy. , 2006, BioTechniques.

[33]  J. Paul Robinson,et al.  Automated classification of bacterial particles in flow by multiangle scatter measurement and support vector machine classifier , 2008, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[34]  P. Marquet,et al.  Comparative study of human erythrocytes by digital holographic microscopy, confocal microscopy, and impedance volume analyzer , 2008, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[35]  F. Emmrich,et al.  Cytomics and nanobioengineering , 2008, Cytometry. Part B, Clinical cytometry.

[36]  A. Beck‐Sickinger,et al.  Microelectrode chip based real time monitoring of vital MCF-7 mamma carcinoma cells by impedance spectroscopy. , 2008, Biosensors & bioelectronics.

[37]  A. Tárnok,et al.  Cytomics and regenerative medicine , 2009, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[38]  S. Gawad,et al.  Micromachined impedance spectroscopy flow cytometer for cell analysis and particle sizing. , 2001, Lab on a chip.

[39]  R. Hoffman,et al.  Flow-system measurement of cell impedance properties. , 1979, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[40]  R. Hoffman,et al.  Flow cytometric electronic direct current volume and radiofrequency impedance measurements of single cells and particles. , 1981, Cytometry.

[41]  S. Gawad,et al.  Single cell dielectric spectroscopy , 2007 .

[42]  J. O'connor,et al.  Multiparametric characterization by flow cytometry of flow‐sorted subpopulations of a human hepatoma cell line useful for drug research , 2005, Cytometry. Part A : the journal of the International Society for Analytical Cytology.