Interventional MR imaging at 1.5 T: quantification of sound exposure.

Sound pressure levels (SPLs) during interventional magnetic resonance (MR) imaging may create an occupational hazard for the interventional radiologist (ie, the potential risk of hearing impairment). Therefore, A-weighted and linear continuous-equivalent SPLs were measured at the entrance of a 1.5-T MR imager during cardiovascular and real-time pulse sequences. The SPLs ranged from 81.5 to 99.3 dB (A-weighted scale), and frequencies were from 1 to 3 kHz. SPLs for the interventional radiologist exceeded a safe SPL of 80 dB (A-weighted scale) for all sequences; therefore, hearing protection is recommended.

[1]  G. Mckinnon Ultrafast interleaved gradient‐echo‐planar imaging on a standard scanner , 1993, Magnetic resonance in medicine.

[2]  F G Shellock,et al.  Measurement of acoustic noise during MR imaging: evaluation of six "worst-case" pulse sequences. , 1994, Radiology.

[3]  M J McJury,et al.  Acoustic noise levels generated during high field MR imaging. , 1995, Clinical radiology.

[4]  R J Smith,et al.  A re-examination of risk estimates from the NIOSH Occupational Noise and Hearing Survey (ONHS) , 1997, The Journal of the Acoustical Society of America.

[5]  A R Palmer,et al.  Sound‐Level Measurements and Calculations of Safe Noise Dosage During EPI at 3 T , 2000, Journal of magnetic resonance imaging : JMRI.

[6]  W. Hall,et al.  Safety, efficacy, and functionality of high-field strength interventional magnetic resonance imaging for neurosurgery. , 2000, Neurosurgery.

[7]  Tzi-Dar Chiueh,et al.  Active cancellation system of acoustic noise in MR imaging , 1999, IEEE Transactions on Biomedical Engineering.

[8]  M McJury,et al.  The use of active noise control (ANC) to reduce acoustic noise generated during MRI scanning: some initial results. , 1997, Magnetic resonance imaging.

[9]  Sharon M. Abel,et al.  Speech understanding in noise with earplugs and muffs in combination , 1999 .

[10]  B B Biswal,et al.  Acoustic echoplanar scanner noise and pure tone hearing thresholds: the effects of sequence repetition times and acoustic noise rates. , 1998, Journal of computer assisted tomography.

[11]  T. Loenneker,et al.  “Silent” MRI with soft gradient pulses , 1999, Magnetic resonance in medicine.

[12]  R I Kitney,et al.  Investigation of acoustic noise on 15 MRI scanners from 0.2 T to 3 T , 2001, Journal of magnetic resonance imaging : JMRI.

[13]  D. L. Spencer,et al.  Active noise reduction versus conventional hearing protection. Relative benefits for normal-hearing and impaired listeners. , 1997, Scandinavian audiology.

[14]  Z H Cho,et al.  Analysis of acoustic noise in MRI. , 1997, Magnetic resonance imaging.

[15]  S. R. Lane,et al.  Acoustic analysis of gradient-coil noise in MR imaging. , 1989, Radiology.

[16]  H H Quick,et al.  Interventional MRA and intravascular imaging , 2000, Journal of magnetic resonance imaging : JMRI.

[17]  F G Shellock,et al.  Auditory noise associated with MR procedures: a review. , 2000, Journal of magnetic resonance imaging : JMRI.

[18]  R E Brummett,et al.  Potential hearing loss resulting from MR imaging. , 1988, Radiology.

[19]  W A Edelstein,et al.  Characterization and prediction of gradient acoustic noise in MR imagers , 1997, Magnetic resonance in medicine.

[20]  E Borg,et al.  MRI acoustic noise: Sound pressure and frequency analysis , 1997, Journal of magnetic resonance imaging : JMRI.

[21]  G. Rosler Progression of Hearing Loss Caused by Occupational Noise , 1994 .

[22]  C K Mechefske,et al.  Gradient‐induced acoustic and magnetic field fluctuations in a 4T whole‐body MR imager , 2000, Magnetic resonance in medicine.

[23]  A. Goldman,et al.  Reduction of sound levels with antinoise in MR imaging. , 1989, Radiology.

[24]  D Atkinson,et al.  Determination of gradient magnetic field‐induced acoustic noise associated with the use of echo planar and three‐dimensional, fast spin echo techniques , 1998, Journal of magnetic resonance imaging : JMRI.