Time dependent 14 MeV neutrons measurement using a polycrystalline chemical vapor deposited diamond detector at the JET tokamak

A polycrystalline chemical vapor deposited (CVD) diamond detector was installed on a JET tokamak in order to monitor the time dependent 14MeV neutron emission produced by D–T plasma pulses during the Trace Tritium Experiment (TTE) performed in October 2003. This was the first tentative ever attempted to use a CVD diamond detector as neutron monitor in a tokamak environment. Despite its small active volume, the detector was able to detect the 14MeV neutron emission (>1.0×1015n∕shot) with good reliability and stability during the experimental campaign that lasted five weeks. The comparison with standard silicon detectors presently used at JET as 14MeV neutron monitors is reported, showing excellent correlation between the measurements. The results prove that CVD diamond detectors can be reliably used in a tokamak environment and therefore confirm the potential of this technology for next step machines like ITER.

[1]  M. Marinelli,et al.  High-quality diamond grown by chemical-vapor deposition: Improved collection efficiency in α-particle detection , 1999 .

[2]  M. Marinelli,et al.  Systematic study of the normal and pumped state of high efficiency diamond particle detectors grown by chemical vapor deposition , 2001 .

[3]  K. Hecht Zum Mechanismus des lichtelektrischen Primärstromes in isolierenden Kristallen , 1932 .

[4]  A. V. Krasilnikov,et al.  TFTR natural diamond detectors based D–T neutron spectrometry system , 1997 .

[5]  R. Tapper,et al.  Diamond detectors in particle physics , 2000 .

[6]  S. Albergo,et al.  Use of high-sensitivity diamond detectors in DC mode for detailed beam-profile measurements in particle accelerators , 2001 .

[7]  R. Aymar,et al.  Overview of ITER-FEAT - The future international burning plasma experiment , 2001 .

[8]  M. Marinelli,et al.  Development and application of CVD diamond detectors to 14 MeV neutron flux monitoring. , 2004, Radiation protection dosimetry.

[9]  Sean Conroy,et al.  Time resolved measurements of triton burnup in JET plasmas , 1988 .

[10]  M. Marinelli,et al.  Trapping and detrapping effects in high-quality chemical-vapor-deposition diamond films: Pulse shape analysis of diamond particle detectors , 2001 .

[11]  D. Colling,et al.  CVD diamond film for neutron counting , 1998 .

[12]  S. Podda,et al.  Measurements of triton burnup in low q discharges in the FT tokamak , 1987 .

[13]  Mario Pillon,et al.  The 14 MeV Frascati neutron generator , 1994 .

[14]  M. Marinelli,et al.  Systematic study of pre-irradiation effects in high efficiency CVD diamond nuclear particle detectors , 2002 .

[15]  Mario Pillon,et al.  14 MeV neutron spectra measurements with 4% energy resolution using a type IIa diamond detector , 1995 .

[16]  Jeffrey A. Koch,et al.  CVD diamond as a high bandwidth neutron detector for inertial confinement fusion diagnostics , 2003 .

[17]  J. Conway,et al.  The development of diamond tracking detectors for the LHC , 2003 .