The effects of prosthesis mass on metabolic cost of ambulation in non-vascular trans-tibial amputees

The effect of prosthesis mass on the metabolic cost of steady-state walking was studied in ten male non-vascular trans-tibial amputees (TTAs) and ten non-amputee controls. The subjects underwent four trials of treadmill ambulation, with each trial performed for nine minutes at level grade and 76 m/min. Twenty minutes of seated rest followed each trial. During trials numbers one and two, TTAs ambulated without mass added to their prosthesis. During the third and fourth trials, either 454 or 907 grammes mass (1 or 2lbs mass respectively) were randomly assigned and added to eithier the prosthesis or the leg of the non-amputee control. Subjects were blinded to the amount of mass added to their limb. Within-group comparisons across the four trials showed significant differences in oxygen consumption (VO2) and heart rate (HR) between the two non “mass added” trials, but no effect for addition of mass. The VO2 of TTAs was only 0.6ml/kg/min (4.7 percent) greater during walking following the addition of 907 grammes to the prosthesis than without mass addition at all, while HR averaged only 1.4 beats/min. higher under the same testing condition. Pearson-product moment correlations echoed these findings, as moderate, but in all cases, negative correlations were observed for associations among the factors of subject age, stump length, and prosthesis-shoe weight, and both VO2 and HR. It was concluded that adding up to 907 grammes mass to a non-vascular TTA's prosthesis will not significantly increase the energy expenditure or HR at a normal walking speed, and that elevated energy cost of ambulation in repeated measures testing without mass added may reflect task familiarisation and not an added burden of prosthesis mass.

[1]  H J Hislop,et al.  Metabolic energy cost of unrestrained walking. , 1976, Physical therapy.

[2]  Y. Ehara,et al.  Energy storing property of so-called energy-storing prosthetic feet. , 1993, Archives of physical medicine and rehabilitation.

[3]  R. Waters,et al.  Energy cost of walking of amputees: the influence of level of amputation. , 1976, The Journal of bone and joint surgery. American volume.

[4]  C. W. Radcliffe The biomechanics of the Syme prosthesis. , 1961, Artificial limbs.

[5]  SOME FACTORS WHICH INFLUENCE THE BALANCE OF THE FOOT IN WALKING , 1937 .

[6]  P. Corcoran,et al.  Energy expenditure in below-knee amputees: correlation with stump length. , 1974, Archives of physical medicine and rehabilitation.

[7]  Energy cost of walking of below-knee amputees having no vascular disease. , 1979, Physical therapy.

[8]  S. Fisher,et al.  Energy cost of ambulation in health and disability: a literature review. , 1978, Archives of physical medicine and rehabilitation.

[9]  D. Winter,et al.  Biomechanics of below-knee amputee gait. , 1988, Journal of biomechanics.

[10]  Corcoran Pj,et al.  Energy expenditure in below-knee amputees: correlation with stump length. , 1974 .

[11]  B. B. Chatterjee,et al.  Metabolic cost of walking at different speeds with patellar tendon-bearing prosthesis. , 1974, Journal of applied physiology.

[12]  R. Waters,et al.  Energy‐speed relationship of walking: Standard tables , 1988, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[13]  V T Inman,et al.  Conservation of energy in ambulation. , 1967, Archives of physical medicine and rehabilitation.

[14]  Ernest M. Burgess SKIN PROBLEMS OF THE AMPUTEE. , 1985 .

[15]  J. Saunders,et al.  The major determinants in normal and pathological gait. , 1953, The Journal of bone and joint surgery. American volume.

[16]  S. Simon Gait Analysis, Normal and Pathological Function. , 1993 .

[17]  Radcliffe Cw The biomechanics of below-knee prostheses in normal, level, bipedal walking. , 1962 .

[18]  S. Levy Skin Problems of the Amputee , 1982 .

[19]  H. Skinner,et al.  Gait analysis in amputees. , 1985, American journal of physical medicine.

[20]  C. W. Radcliffe,et al.  Functional considerations in the fitting of above-knee prostheses. , 1955, Artificial limbs.

[21]  M. Nash,et al.  Energy expenditure of trans-tibial amputees during ambulation at self-selected pace , 1994, Prosthetics and orthotics international.

[22]  Radcliffe Cw,et al.  Functional considerations in the fitting of above-knee prostheses. , 1955 .

[23]  J. Perry,et al.  Gait Analysis , 2024 .

[24]  Harris Ri The history and development of Syme's amputation. , 1961 .

[25]  P. D. Wilson,et al.  Human Limbs and Their Substitutes , 1969 .

[26]  J. Czerniecki,et al.  BIOMECHANICAL ANALYSIS OF THE INFLUENCE OF PROSTHETIC FEET ON BELOW-KNEE AMPUTEE WALKING , 1991, American journal of physical medicine & rehabilitation.

[27]  C. T. Huang,et al.  Amputation: energy cost of ambulation. , 1979, Archives of physical medicine and rehabilitation.

[28]  V. T. Inman Human locomotion. , 1966, Canadian Medical Association journal.

[29]  V. Mooney Human Limbs and Their Substitutes , 1969 .

[30]  H J Hislop,et al.  Energetics: application to the study and management of locomotor disabilities. Energy cost of normal and pathologic gait. , 1978, The Orthopedic clinics of North America.

[31]  F. Finley,et al.  Locomotive characteristics of urban pedestrians. , 1970, Archives of physical medicine and rehabilitation.

[32]  Corcoran Pj,et al.  Oxygen uptake in normal and handicapped subjects, in relation to speed of waing beside velocity-controlled cart. , 1970 .

[33]  Skinner Hb,et al.  Gait analysis in amputees. , 1985 .

[34]  K V Kuhlemeier,et al.  Energy cost of ambulation in paraplegic patients using Craig-Scott braces. , 1979, Archives of physical medicine and rehabilitation.

[35]  B. Saltin,et al.  Effect of training on circulatory response to exercise. , 1968, Journal of applied physiology.