Experimental assessment and modelling of the performance of an open joint ventilated façade during actual operating conditions in Mediterranean climate

Abstract In this work, the performance of a real ventilated facade has been investigated both experimentally and numerically. The studied facade is south oriented and belongs to a building located in Almeria, a city in the South of Spain with warm Mediterranean climate. Experimental data, based on temperature, heat fluxes and incident radiation on the facade have been collected during one year. The experimental data have been used to analyse the energy performance of the facade during the summer and the winter periods. The results show that in warm climates with high levels of solar radiation, the ventilated facade can play an important role in reducing the heating and cooling thermal loads as long as the outdoor temperatures are not extreme. Additionally, a model based on fluid dynamic simulation techniques is proposed. The comparison with experimental data shows the importance of including the reflected radiation from the ground in the thermal modelling of the facade. The proposed model can predict temperatures and heat fluxes to the room with deviations lower than 10%.

[1]  Dias Haralambopoulos,et al.  Assessing the thermal insulation of old buildings—The need for in situ spot measurements of thermal resistance and planar infrared thermography , 1998 .

[2]  Francesco Patania,et al.  Thermofluid-dynamic analysis of ventilated facades , 2010 .

[3]  A. Schaelin,et al.  Airflow patterns and thermal behavior of mechanically ventilated glass double façades , 2004 .

[4]  D. Gray,et al.  The validity of the boussinesq approximation for liquids and gases , 1976 .

[5]  S. Orszag,et al.  Renormalization group analysis of turbulence. I. Basic theory , 1986, Physical review letters.

[6]  Qingyan Chen COMPARISON OF DIFFERENT k-ε MODELS FOR INDOOR AIR FLOW COMPUTATIONS , 1995 .

[7]  Eduard Egusquiza,et al.  Performance and influence of numerical sub-models on the CFD simulation of free and forced convection in double-glazed ventilated façades , 2008 .

[8]  Dirk Saelens,et al.  Experimental Evaluation of Airflow in Naturally Ventilated Active Envelopes , 2001 .

[9]  Martin R. Wolf,et al.  K3 User Guide , 2000 .

[10]  Henrik Madsen,et al.  Estimation of non-linear continuous time models for the heat exchange dynamics of building integrated photovoltaic modules , 2008 .

[11]  Gian Luca Morini,et al.  Empirical validation and modelling of a naturally ventilated rainscreen faade building , 2011 .

[12]  Eduardo Blanco,et al.  447: Numerical study on thermal and fluid dynamic behaviour of an open-joint ventilated façade , 2008 .

[13]  Eduardo Blanco,et al.  CFD analysis of heat collection in a glazed gallery , 2011 .

[14]  Ermanno G. Grinzato,et al.  Quantitative infrared thermography in buildings , 1998 .

[15]  P. H. Baker,et al.  Test cell evaluation of supply air windows to characterise their optimum performance and its verification by the use of modelling techniques , 2003 .

[16]  Van Straaten,et al.  Thermal Performance of Buildings , 1967 .

[17]  S. Orszag,et al.  Renormalization group analysis of turbulence. I. Basic theory , 1986 .

[18]  B. Launder,et al.  The numerical computation of turbulent flows , 1990 .

[19]  G. Raithby,et al.  COMPUTATION OF RADIANT HEAT TRANSFER ON A NONORTHOGONAL MESH USING THE FINITE-VOLUME METHOD , 1993 .

[20]  E. Blanco,et al.  Energy performance of an open-joint ventilated façade compared with a conventional sealed cavity façade , 2011 .

[21]  Wu Yao,et al.  Application of Infrared Thermography Technique in Building Finish Evaluation , 2000 .

[22]  Eduardo Blanco,et al.  Development and experimental validation of a simulation model for open joint ventilated façades , 2011 .