Compact, modular and in-plane AOSLO for high-resolution retinal imaging

The adaptive optics scanning laser ophthalmoscope (AOSLO) was first developed in 2002 and since then the technology has been adopted in several laboratories around the world, for both clinical and psychophysical research. There have been a few major design implementations of the AOSLO. The first used on-axis tilted spherical mirrors in a planar arrangement, and the second minimized the build up of astigmatism present in the first design by using a non-planar arrangement. Other designs have avoided astigmatism by using custom-made toroidal mirrors or by using lenses on-axis, rather than mirrors. We present a new design implementation for an AOSLO that maintains a planar optical alignment without the build up astigmatism using compact, reconfigurable modules based on an Offner relay system. We additionally use an off-the-shelf digital oscilloscope for data capture and custom-written Python code for generating and analyzing the retinal images. This design results in a compact system that is simple to align and, being composed of modular relays, has the potential for additional components to be added. We show that this system maintains diffraction-limited image quality across the field of view and that cones are clearly resolved in the central retina. The modular relay design is generally applicable to any system requiring one or more components in the pupil conjugate plane. This is likely to be useful for any point-scanned system, such as a standard scanning laser ophthalmoscope or non-ophthalmic confocal imaging system.

[1]  R. Webb,et al.  Flying spot TV ophthalmoscope. , 1980, Applied optics.

[2]  A. Roorda,et al.  Observation of cone and rod photoreceptors in normal subjects and patients using a new generation adaptive optics scanning laser ophthalmoscope , 2011, Biomedical optics express.

[3]  P. Sharp,et al.  The scanning laser ophthalmoscope. , 1997, Physics in medicine and biology.

[4]  Toco Y P Chui,et al.  The use of forward scatter to improve retinal vascular imaging with an adaptive optics scanning laser ophthalmoscope , 2012, Biomedical optics express.

[5]  Jennifer J. Hunter,et al.  Imaging individual neurons in the retinal ganglion cell layer of the living eye , 2017, Proceedings of the National Academy of Sciences.

[6]  Fabrice Manns,et al.  Correcting for Miniature Eye Movements in High Resolution Scanning Laser Ophthalmoscopy , 2005 .

[7]  Abe Offner,et al.  New Concepts in Projection Mask Aligners , 1975 .

[8]  R. Webb,et al.  Confocal scanning laser ophthalmoscope. , 1987, Applied optics.

[9]  Nicusor Iftimia,et al.  Multimodal adaptive optics retinal imager: design and performance. , 2012, Journal of the Optical Society of America. A, Optics, image science, and vision.

[10]  A. Dubra,et al.  In vivo dark-field imaging of the retinal pigment epithelium cell mosaic. , 2013, Biomedical optics express.

[11]  Stephen A Burns,et al.  Local flicker stimulation evokes local retinal blood velocity changes. , 2012, Journal of vision.

[12]  Jennifer J. Hunter,et al.  Vision science and adaptive optics, the state of the field , 2017, Vision Research.

[13]  Xavier Levecq,et al.  Multi-modal adaptive optics system including fundus photography and optical coherence tomography for the clinical setting , 2016, Biomedical optics express.

[14]  Michael Pircher,et al.  Lens based adaptive optics scanning laser ophthalmoscope. , 2012, Optics express.

[15]  John A. Nelder,et al.  A Simplex Method for Function Minimization , 1965, Comput. J..

[16]  Daniel X. Hammer,et al.  High resolution multimodal clinical ophthalmic imaging system , 2010, Optics express.

[17]  Christopher S. Langlo,et al.  In vivo imaging of human cone photoreceptor inner segments. , 2014, Investigative ophthalmology & visual science.

[18]  David R Williams,et al.  Deconvolution of adaptive optics retinal images. , 2004, Journal of the Optical Society of America. A, Optics, image science, and vision.

[19]  T. Hebert,et al.  Adaptive optics scanning laser ophthalmoscopy. , 2002, Optics express.

[20]  Austin Roorda,et al.  Mapping the Perceptual Grain of the Human Retina , 2014, The Journal of Neuroscience.

[21]  A. Roorda,et al.  Direct and noninvasive assessment of parafoveal capillary leukocyte velocity. , 2005, Ophthalmology.

[22]  Jeffrey B. Mulligan,et al.  Recovery of motion parameters from distortions in scanned images , 1997 .

[23]  Omer P. Kocaoglu,et al.  In-the-plane design of an off-axis ophthalmic adaptive optics system using toroidal mirrors. , 2013, Biomedical optics express.

[24]  P Artal,et al.  High-resolution retinal images obtained by deconvolution from wave-front sensing. , 2000, Optics letters.

[25]  Gaël Varoquaux,et al.  The NumPy Array: A Structure for Efficient Numerical Computation , 2011, Computing in Science & Engineering.

[26]  Alfredo Dubra,et al.  Adaptive Optics Retinal Imaging – Clinical Opportunities and Challenges , 2013, Current eye research.

[27]  Scot S. Olivier,et al.  Two deformable mirror adaptive optics system for in vivo retinal imaging with optical coherence tomography , 2006 .