Timing-Invariant CT Angiography Derived from CT Perfusion Imaging in Acute Stroke: A Diagnostic Performance Study

BACKGROUND AND PURPOSE: Timing-invariant (or delay-insensitive) CT angiography derived from CT perfusion data may obviate a separate cranial CTA in acute stroke, thus enhancing patient safety by reducing total examination time, radiation dose, and volume of contrast material. We assessed the diagnostic accuracy of timing-invariant CTA for detecting intracranial artery occlusion in acute ischemic stroke, to examine whether standard CTA can be omitted. MATERIALS AND METHODS: Patients with suspected ischemic stroke were prospectively enrolled and underwent CTA and CTP imaging at admission. Timing-invariant CTA was derived from the CTP data. Five neuroradiologic observers assessed all images for the presence and location of intracranial artery occlusion in a blinded and randomized manner. Sensitivity and specificity of timing-invariant CTA and standard CTA were calculated by using an independent expert panel as the reference standard. Interrater agreement was determined by using κ statistics. RESULTS: We included 108 patients with 47 vessel occlusions. Overall, standard CTA and timing-invariant CTA provided similar high diagnostic accuracy for occlusion detection with a sensitivity of 96% (95% CI, 90%–100%) and a specificity of 100% (99%–100%) for standard CTA and a sensitivity of 98% (95% CI, 94%–100%) and a specificity of 100% (95% CI, 100%–100%) for timing-invariant CTA. For proximal large-vessel occlusions, defined as occlusions of the ICA, basilar artery, and M1, the sensitivity and specificity were 100% (95% CI, 100%–100%) for both techniques. Interrater agreement was good for both techniques (mean κ value, 0.75 and 0.76). CONCLUSIONS: Timing-invariant CTA derived from CTP data provides diagnostic accuracy similar to that of standard CTA for the detection of artery occlusions in acute stroke.

[1]  Ernst Klotz,et al.  Angiographic Reconstructions From Whole-Brain Perfusion CT for the Detection of Large Vessel Occlusion in Acute Stroke , 2012, Stroke.

[2]  M. Lev,et al.  Acute Stroke Imaging: What Is Sufficient for Triage to Endovascular Therapies? , 2012, American Journal of Neuroradiology.

[3]  K. Bae,et al.  Intravenous contrast medium administration and scan timing at CT: considerations and approaches. , 2010, Radiology.

[4]  Ken Butcher,et al.  Collateral blood vessels in acute ischaemic stroke: a potential therapeutic target , 2011, The Lancet Neurology.

[5]  Bram van Ginneken,et al.  Timing-Invariant Imaging of Collateral Vessels in Acute Ischemic Stroke , 2013, Stroke.

[6]  A. Huang,et al.  Multiphase CT Angiography versus Single-Phase CT Angiography: Comparison of Image Quality and Radiation Dose , 2008, American Journal of Neuroradiology.

[7]  P. Willems,et al.  Detection and Classification of Cranial Dural Arteriovenous Fistulas Using 4D-CT Angiography: Initial Experience , 2010, American Journal of Neuroradiology.

[8]  Ernst Klotz,et al.  Time-resolved assessment of collateral flow using 4D CT angiography in large-vessel occlusion stroke , 2014, European Radiology.

[9]  B. van Ginneken,et al.  Timing-invariant reconstruction for deriving high-quality CT angiographic data from cerebral CT perfusion data. , 2012, Radiology.

[10]  R. Edelman,et al.  Evidence-based guideline: The role of diffusion and perfusion MRI for the diagnosis of acute ischemic stroke , 2010, Neurology.

[11]  M. Wintermark,et al.  Acute stroke triage to intravenous thrombolysis and other therapies with advanced CT or MR imaging: pro CT. , 2009, Radiology.

[12]  J. Wetzels,et al.  Epidemiology of contrast material-induced nephropathy in the era of hydration. , 2012, Radiology.

[13]  S. El-Saden,et al.  Imaging of the internal carotid artery: the dilemma of total versus near total occlusion. , 2001, Radiology.

[14]  J. Pell,et al.  Carotid artery stenosis: accuracy of noninvasive tests--individual patient data meta-analysis. , 2009, Radiology.

[15]  Valentin Fuster,et al.  Imaging of atherosclerosis: magnetic resonance imaging. , 2011, European heart journal.

[16]  Walter Huda,et al.  Converting dose-length product to effective dose at CT. , 2008, Radiology.