Identification of coherent generator groups in power system networks with windfarms

This paper presents coherency based analysis technique for network reduction to carry out transient stability analysis for a power system that has some wind penetration. Identification of coherent groups targets to obtain simplified dynamic equivalent of system by aggregation of coherent generators using an equivalent generator. Equivalent model can transform a large power system into a reduced model, localized into a small internal area containing the fault. This paper aims to illustrate the procedure of obtaining coherent generators with and without windfarms in the system. Coherency based analysis has been carried out on The New England 39 Bus 10 machine system with windfarms. Simulations for this test system are obtained using DigSilent-Power factory software.

[1]  A.H.M.A. Rahim,et al.  An efficient method of identifying coherent generators using Taylor series expansion , 1988 .

[2]  Y. Ni,et al.  Impact of Wind Farms of DFIG Type on Power System Transient Stability , 2010 .

[3]  A. M. Leite da Silva,et al.  An efficient methodology for coherency-based dynamic equivalents , 1992 .

[4]  K. R. Padiyar,et al.  ENERGY FUNCTION ANALYSIS FOR POWER SYSTEM STABILITY , 1990 .

[5]  M. Ribbens-Pavella,et al.  Extended Equal Area Criterion Justifications, Generalizations, Applications , 1989, IEEE Power Engineering Review.

[6]  Jürgen Stenzel,et al.  Impact of large scale wind power on power system stability , 2005 .

[7]  L. Allen,et al.  Utility Experience With Coherency-Based Dynamic Equivalents Of Very Large Systems , 1985, IEEE Transactions on Power Apparatus and Systems.

[8]  R. Podmore,et al.  Dynamic Aggregation of Generating Unit Models , 1978, IEEE Transactions on Power Apparatus and Systems.

[9]  Mania Ribbens-Pavella,et al.  A simple direct method for fast transient stability assessment of large power systems , 1988 .

[10]  H. Pinheiro,et al.  An Analytical Tool for Computing Transient Stability Margins of Power Systems with Large Amount of Wind Power , 2007, 2007 International Conference on Clean Electrical Power.

[11]  B. Spalding,et al.  Coherency recognition for transient stability studies using singular points , 1977, IEEE Transactions on Power Apparatus and Systems.

[12]  A. M. Miah Simple dynamic equivalent for fast online transient stability assessment , 1998 .

[13]  P. Kundur,et al.  Power system stability and control , 1994 .

[14]  Vijay Vittal,et al.  Impact of increased penetration of DFIG based wind turbine generators on transient and small signal stability of power systems , 2009, IEEE PES General Meeting.

[15]  Jegath C. Giri Coherency Reduction in the EPRI Stability Program , 1983, IEEE Power Engineering Review.

[16]  Vijay Vittal,et al.  Power System Transient Stability Analysis Using the Transient Energy Function Method , 1991 .

[17]  Robin Podmore,et al.  Identification of Coherent Generators for Dynamic Equivalents , 1978, IEEE Transactions on Power Apparatus and Systems.

[18]  Louis Wehenkel,et al.  Extended equal area criterion revisited (EHV power systems) , 1992 .

[19]  Damien Ernst,et al.  Transient Stability of Power Systems: A Unified Approach to Assessment and Control , 2000 .

[20]  A. Fouad,et al.  Transient Stability of a Multi-Machine Power System. Part II: Critical Transient Energy , 1981, IEEE Transactions on Power Apparatus and Systems.

[21]  A. Fouad,et al.  Transient Stability of a Multi-Machine Power System Part I: Investigation of System Trajectories , 1981, IEEE Transactions on Power Apparatus and Systems.

[22]  A. A. Fouad,et al.  Transient Stability of a Multi-Machine Power System. Part II: Critical Transient Energy , 1981 .