Liquid chromatography/tandem mass spectrometry methods for quantitation of mevalonic acid in human plasma and urine: method validation, demonstration of using a surrogate analyte, and demonstration of unacceptable matrix effect in spite of use of a stable isotope analog internal standard.

Selective, accurate, and reproducible liquid chromatography/tandem mass spectrometry (LC/MS/MS) methods were developed and validated for the determination of mevalonic acid, an intermediate in the biosynthesis of cholesterol and therefore a useful biomarker in the development of cholesterol lowering drugs, in human plasma and urine. A hepta-deuterated analog of mevalonic acid was used as the internal standard. For both methods, calibration standards were prepared in water, instead of human plasma and urine, due to unacceptably high levels of endogenous mevalonic acid. The lower quality control (QC) samples were prepared in water while the higher QC samples were prepared in the biological matrices. For the isolation/purification of mevalonic acid from the plasma and urine matrices, the samples were first acidified to convert the acid analyte into its lactone form. For the plasma samples, the lactone analyte was retained on and then eluted off a polymeric solid-phase extraction (SPE) sorbent. For the urine method, the sample containing the lactone analyte was passed through a C-18 SPE column, which did not retain the analyte, with the subsequent analyte retention on and then elution off a polymeric SPE sorbent. Chromatographic separation was achieved isocratically on a polar-endcapped C-18 analytical column with a water/methanol mobile phase containing 0.5 mM formic acid. Detection was by negative-ion electrospray tandem mass spectrometry. The standard curve range was 0.500-20.0 ng/mL for the plasma method and 25.0-1,000 ng/mL for the urine method. Excellent accuracy and precision were obtained for both methods at all concentration levels tested. It was interesting to note that for certain batches of urine, when a larger sample volume was used for analysis, a high degree of matrix effect was observed which resulted not only in the attenuation of the absolute response, but also in a change of analyte/internal standard response ratio. This demonstrated that, under certain conditions, the use of a stable isotope analog internal standard does not, contrary to conventional thinking, guarantee the constancy of the analyte/internal response ratio, which is a prerequisite for a rugged bioanalytical method. On the other hand, under conditions where the sample matrix does not have such a deleterious effect, we have found that a stable isotope analog could serve as a surrogate (substitute) analyte. Thus, we have shown that using calibration standards prepared by spiking plasma with tri-deuterated or tetra-deuterated mevalonic acid, instead of mevalonic acid itself (the analyte), plasma QC samples that contain mevalonic acid can be successfully analyzed for the accurate and precise quantitation of mevalonic acid. The use of a surrogate analyte provides the opportunity to gauge the daily performance of the method for the low concentration levels prepared in the biological matrix, which otherwise is not achievable because of the endogenous concentrations of the analyte in the biological matrices.

[1]  T. Risler,et al.  Acute and chronic effects on cholesterol biosynthesis of LDL-apheresis with or without concomitant HMG-CoA reductase inhibitor therapy. , 1994, Journal of lipid research.

[2]  J. Layne Characterization and comparison of the chromatographic performance of conventional, polar-embedded, and polar-endcapped reversed-phase liquid chromatography stationary phases. , 2002, Journal of chromatography. A.

[3]  M. Krempf,et al.  Measurement of mevalonic acid in human urine by bench top gas chromatography-mass spectrometry. , 1995, Clinica chimica acta; international journal of clinical chemistry.

[4]  Paul D. Martin,et al.  Validation and application of an assay for the determination of mevalonic acid in human plasma by liquid chromatography tandem mass spectrometry. , 2002, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[5]  B. Woollen,et al.  Determination of mevalonic acid in human urine as mevalonic acid lactone by gas chromatography-mass spectrometry. , 2001, Journal of chromatography. B, Biomedical sciences and applications.

[6]  L. Romanyshyn,et al.  Implications of matrix effects in ultra-fast gradient or fast isocratic liquid chromatography with mass spectrometry in drug discovery. , 2002, Rapid communications in mass spectrometry : RCM.

[7]  J. Pezzuto,et al.  Analysis of 3-hydroxy-3-methylglutaryl-coenzyme A reductase inhibitors using liquid chromatography-electrospray mass spectrometry. , 2001, Journal of chromatography. B, Biomedical sciences and applications.

[8]  G. Taylor,et al.  Plasma mevalonic acid, an index of cholesterol synthesis in vivo, and responsiveness to HMG-CoA reductase inhibitors in familial hypercholesterolaemia. , 1996, Atherosclerosis.

[9]  B. Matuszewski,et al.  Matrix effect in quantitative LC/MS/MS analyses of biological fluids: a method for determination of finasteride in human plasma at picogram per milliliter concentrations. , 1998, Analytical chemistry.

[10]  T. Olah,et al.  The effects of sample preparation methods on the variability of the electrospray ionization response for model drug compounds. , 1999, Rapid communications in mass spectrometry : RCM.

[11]  D. Hercules,et al.  Effect of liquid chromatography separation of complex matrices on liquid chromatography-tandem mass spectrometry signal suppression. , 2001, Journal of chromatography. A.

[12]  Paul D. Martin,et al.  Development of a sensitive assay for the determination of mevalonic acid in urine and its application to clinical studies with rosuvastatin , 2002 .

[13]  Z. Ouyang,et al.  High performance liquid chromatography mobile phase composition optimization for the quantitative determination of a carboxylic acid compound in human plasma by negative ion electrospray high performance liquid chromatography tandem mass spectrometry. , 1998, Rapid communications in mass spectrometry : RCM.

[14]  W. Weinmann,et al.  Ion suppression effects in liquid chromatography-electrospray-ionisation transport-region collision induced dissociation mass spectrometry with different serum extraction methods for systematic toxicological analysis with mass spectra libraries. , 2002, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[15]  D L Buhrman,et al.  Quantitation of SR 27417 in human plasma using electrospray liquid chromatography-tandem mass spectrometry: A study of ion suppression , 1996, Journal of the American Society for Mass Spectrometry.

[16]  Y. Saisho,et al.  A sensitive and selective method for the determination of mevalonic acid in dog plasma by gas chromatography/negative ion chemical ionization-mass spectrometry. , 1997, Journal of pharmaceutical and biomedical analysis.

[17]  L. Sweetman,et al.  An improved chemical ionization assay for mevalonic acid. , 1990, Biomedical & environmental mass spectrometry.

[18]  K. von Bergmann,et al.  Urinary excretion and serum concentration of mevalonic acid during acute intake of alcohol. , 2000, Metabolism: clinical and experimental.

[19]  E. Woolf,et al.  Effect of the sample matrix on the determination of indinavir in human urine by HPLC with turbo ion spray tandem mass spectrometric detection. , 1998, Journal of pharmaceutical and biomedical analysis.

[20]  K. von Bergmann,et al.  Determination of urinary mevalonic acid using isotope dilution technique. , 1994, Biological mass spectrometry.