Reliability of pulse oximetry in titrating supplemental oxygen therapy in ventilator-dependent patients.

Pulse oximetry is widely used in the critical care setting, but few studies have examined its usefulness in clinical decision making. One area where pulse oximetry might be useful is in the titration of fractional inspired O2 concentration (FIO2) in ventilator-dependent patients. Unfortunately, documented guidelines for this use do not exist, and in a survey of directors of intensive care units, we found that they employed a wide range of target O2 saturation (SpO2) values. Consequently, we undertook a study to determine if SpO2 could be reliably substituted for measurements of arterial O2 tension (PaO2) when adjusting FIO2 in ventilator-dependent patients. We examined a number of SpO2 target values in 54 critically ill patients aiming for a PaO2 of greater than or equal to 60 mm Hg, while minimizing the risk of O2 toxicity. In white patients, we found that a SpO2 target of 92 percent was reliable in predicting a satisfactory level of oxygenation. However, in black patients, such a SpO2 reading was commonly associated with significant hypoxemia (PaO2 as low as 49 mm Hg), and a higher SpO2 target, 95 percent, was required. In addition, inaccurate oximetry readings (ie, greater than 4 percent difference between SpO2 and direct SaO2 measurements) were more common in black (27 percent) than in white patients (11 percent, p less than 0.05). In conclusion, a SpO2 target of 92 percent was reliable when titrating supplemental O2 in white patients receiving mechanical ventilation; however, in black patients, such a SpO2 reading was commonly associated with significant hypoxemia, and a higher SpO2 target, 95 percent, was required to ensure a satisfactory level of oxygenation.

[1]  D C Hoaglin,et al.  The Effect of Nail Polish on Pulse Oximetry , 1988, Anesthesia and analgesia.

[2]  A. Ries,et al.  Skin color and ear oximetry. , 1989, Chest.

[3]  H. Wollman,et al.  Complications of Percutaneous Radial-artery Cannulation: An Objective Prospective Study in Man , 1973, Anesthesiology.

[4]  J A Pologe,et al.  Pulse Oximetry: Technical Aspects of Machine Design , 1987, International anesthesiology clinics.

[5]  M J Tobin,et al.  Respiratory monitoring in the intensive care unit. , 1988, The American review of respiratory disease.

[6]  Douglas G. Altman,et al.  Measurement in Medicine: The Analysis of Method Comparison Studies , 1983 .

[7]  J. Severinghaus,et al.  History of blood gas analysis. , 1987, International anesthesiology clinics.

[8]  K. Tremper,et al.  ACCURACY OF A PULSE OXIMETER IN THE CRITICALLY ILL ADULT: EFFECT OF TEMPERATURE AND HEMODYNAMICS , 1985 .

[9]  A. Rebuck,et al.  The accuracy and response characteristics of a simplified ear oximeter. , 1983, Chest.

[10]  Mark Yelderman,et al.  Evaluation of pulse oximetry. , 1983, Anesthesiology.

[11]  N. Saunders,et al.  Ear oximetry: accuracy and practicability in the assessment of arterial oxygenation. , 1976, The American review of respiratory disease.

[12]  M. F. Battito The effect of fingerprinting ink on pulse oximetry. , 1989, Anesthesia and analgesia.

[13]  K Tremper,et al.  Bias and precision of pulse oximeters and arterial oximeters. , 1988, Chest.

[14]  F. Mihm,et al.  Noninvasive detection of profound arterial desaturations using a pulse oximetry device. , 1985, Anesthesiology.

[15]  A. Ries,et al.  Accuracy of two ear oximeters at rest and during exercise in pulmonary patients. , 2015, The American review of respiratory disease.