The modified super-ellipsoid yield criterion for human trabecular bone.

Despite the importance of multiaxial failure of trabecular bone in many biomechanical applications, to date no complete multiaxial failure criterion for human trabecular bone has been developed. By using experimentally validated nonlinear high-resolution, micromechanical finite-element models as a surrogate for multiaxial loading experiments, we determined the three-dimensional normal strain yield surface and all combinations of the two-dimensional normal-shear strain yield envelope. High-resolution finite-element models of three human femoral neck trabecular bone specimens obtained through microcomputed tomography were used. In total, 889 multiaxial-loading cases were analyzed, requiring over 41,000 CPU hours on parallel supercomputers. Our results indicated that the multiaxial yield behavior of trabecular bone in strain space was homogeneous across the specimens and nearly isotropic. Analysis of stress-strain curves along each axis in the 3-D normal strain space indicated uncoupled yield behavior whereas substantial coupling was seen for normal-shear loading. A modified super-ellipsoid surface with only four parameters fit the normal strain yield data very well with an arithmetic error +/-SD less than -0.04 +/- 5.1%. Furthermore, the principal strains associated with normal-shear loading showed excellent agreement with the yield surface obtained for normal strain loading (arithmetic error +/- SD < 2.5 +/- 6.5%). We conclude that the four-parameter "Modified Super-Ellipsoid" yield surface presented here describes the multiaxial failure behavior of human femoral neck trabecular bone very well.

[1]  C. Turner,et al.  Yield behavior of bovine cancellous bone. , 1989, Journal of biomechanical engineering.

[2]  M L Bouxsein,et al.  Effect of local density changes on the failure load of the proximal femur , 1999, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[3]  S. Cowin Imaging of Bone Structure , 2001 .

[4]  G. Niebur,et al.  High-resolution finite element models with tissue strength asymmetry accurately predict failure of trabecular bone. , 2000, Journal of biomechanics.

[5]  Michael F. Ashby,et al.  Failure surfaces for cellular materials under multiaxial loads—I.Modelling , 1989 .

[6]  Stephen C. Cowin,et al.  FABRIC DEPENDENCE OF AN ANISOTROPIC STRENGTH CRITERION , 1986 .

[7]  M. Zaslawsky Multiaxial-stress studies on rigid polyurethane foam , 1973 .

[8]  R. Huiskes,et al.  Direct mechanics assessment of elastic symmetries and properties of trabecular bone architecture. , 1996, Journal of biomechanics.

[9]  T. Keaveny,et al.  Mechanisms of uniformity of yield strains for trabecular bone. , 2004, Journal of biomechanics.

[10]  T. Keaveny,et al.  Uniaxial yield strains for bovine trabecular bone are isotropic and asymmetric , 1999, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[11]  W. Hayes,et al.  Fracture prediction for the proximal femur using finite element models: Part II--Nonlinear analysis. , 1991, Journal of biomechanical engineering.

[12]  G. Niebur,et al.  Convergence behavior of high-resolution finite element models of trabecular bone. , 1999, Journal of biomechanical engineering.

[13]  Sharmila Majumdar,et al.  Contribution of inter-site variations in architecture to trabecular bone apparent yield strains. , 2004, Journal of biomechanics.

[14]  Y P Arramon,et al.  Application of the Tsai-Wu quadratic multiaxial failure criterion to bovine trabecular bone. , 1999, Journal of biomechanical engineering.

[15]  Glen L Niebur,et al.  Biaxial failure behavior of bovine tibial trabecular bone. , 2002, Journal of biomechanical engineering.

[16]  W. Hayes,et al.  Stress analysis of a condylar knee tibial component: Influence of metaphyseal shell properties and cement injection depth , 1985, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[17]  Mark F. Adams,et al.  Evaluation of three unstructured multigrid methods on 3D finite element problems in solid mechanics , 2000 .

[18]  T. Keaveny,et al.  Effects of Bone Cement Volume and Distribution on Vertebral Stiffness After Vertebroplasty , 2001, Spine.

[19]  Barr,et al.  Superquadrics and Angle-Preserving Transformations , 1981, IEEE Computer Graphics and Applications.

[20]  J. Kinney,et al.  On the importance of geometric nonlinearity in finite-element simulations of trabecular bone failure. , 2003, Bone.

[21]  Stephen W. Tsai,et al.  A General Theory of Strength for Anisotropic Materials , 1971 .

[22]  T M Keaveny,et al.  Three-dimensional imaging of trabecular bone using the computer numerically controlled milling technique. , 1997, Bone.

[23]  Michael F. Ashby,et al.  Failure surfaces for cellular materials under multiaxial loads—II. Comparison of models with experiment , 1989 .

[24]  W. Fan,et al.  On phenomenological anisotropic failure criteria , 1987 .

[25]  P. Rüegsegger,et al.  Direct Three‐Dimensional Morphometric Analysis of Human Cancellous Bone: Microstructural Data from Spine, Femur, Iliac Crest, and Calcaneus , 1999, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[26]  W C Hayes,et al.  Differences between the tensile and compressive strengths of bovine tibial trabecular bone depend on modulus. , 1994, Journal of biomechanics.

[27]  S. Goldstein,et al.  Femoral strength is better predicted by finite element models than QCT and DXA. , 1999, Journal of biomechanics.

[28]  J H Keyak,et al.  Prediction of femoral fracture load using finite element models: an examination of stress- and strain-based failure theories. , 2000, Journal of biomechanics.

[29]  T M Keaveny,et al.  A cellular solid criterion for predicting the axial-shear failure properties of bovine trabecular bone. , 1999, Journal of biomechanical engineering.

[30]  W. Hayes,et al.  The effect of impact direction on the structural capacity of the proximal femur during falls , 1996, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[31]  P. Rüegsegger,et al.  A microtomographic system for the nondestructive evaluation of bone architecture , 2006, Calcified Tissue International.

[32]  G. Niebur,et al.  Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue. , 2004, Journal of biomechanics.

[33]  T. Keaveny,et al.  Dependence of yield strain of human trabecular bone on anatomic site. , 2001, Journal of biomechanics.

[34]  W. Hayes,et al.  Multiaxial strength characteristics of trabecular bone. , 1983, Journal of biomechanics.

[35]  W C Hayes,et al.  Micro-compression: a novel technique for the nondestructive assessment of local bone failure. , 1998, Technology and health care : official journal of the European Society for Engineering and Medicine.

[36]  W. Hayes,et al.  Fracture prediction for the proximal femur using finite element models: Part I--Linear analysis. , 1991, Journal of biomechanical engineering.