Experimental assessment of a solar desiccant cooling system for an institutional building in subtropical Queensland, Australia

In this paper a hybrid solar desiccant cooling system which has been designed and installed at the Rockhampton campus of Central Queensland University, Queensland, Australia is experimentally investigated. The cooling system consists of four main components: a solar system, a desiccant dehumidifier, an evaporative cooler and a vapour compression cooling system. In addition, experimental results are presented alongside analytical results of the installed solar desiccant cooling system to evaluate the system performance parameters. The system parameters have been simulated using TRNSYS 16 in two previous studies. The experimental and simulated results are analysed on the basis of energy savings, solar fraction (SF), primary energy used, coefficient of performance (COP) and desiccant system efficiency. Results showed that the installed cooling system at Central Queensland University achieved 18% energy savings with maximum coefficient of performance of 0.83 and 48% desiccant efficiency.

[1]  S. A. Sherif,et al.  A feasibility study of a solar desiccant air-conditioning system. Part II : Transient simulation and economics , 1999 .

[2]  Jeff W. Thornton,et al.  TRNSYS - FEATURES AND FUNCTIONALITITY FOR BUILDING SIMULATION 2009 CONFERENCE , 2009 .

[3]  Mohammad. Rasul,et al.  Solar desiccant cooling and indoor air quality for institutional building in subtropical climate (review) , 2012 .

[4]  Mehmet Kanoglu,et al.  Energy and exergy analyses of an experimental open-cycle desiccant cooling system. , 2004 .

[5]  Hugh W. Coleman,et al.  Experimentation and Uncertainty Analysis for Engineers , 1989 .

[6]  Fatemeh Esfandiari Nia,et al.  Modeling and simulation of desiccant wheel for air conditioning , 2006 .

[7]  Ryuichiro Yoshie,et al.  Performance of solar-desiccant cooling system with Silica-Gel (SiO2) and Titanium Dioxide (TiO2) desiccant wheel applied in East Asian climates , 2012 .

[8]  Tianshu Ge,et al.  Technical development of rotary desiccant dehumidification and air conditioning: A review , 2010 .

[9]  Kamaruzzaman Sopian,et al.  Feasibility Study and Performance Analysis of Solar Assisted Desiccant Cooling Technology in Hot and Humid Climate , 2011 .

[10]  Shahab Alizadeh,et al.  Performance of a solar liquid desiccant air conditioner : An experimental and theoretical approach , 2008 .

[11]  Mohammad Masud Kamal. Khan,et al.  Assessment of solar assisted air conditioning in Central Queensland's subtropical climate, Australia , 2013 .

[12]  Mehmet Kanoglu,et al.  Effect of ambient conditions on the first and second law performance of an open desiccant cooling process , 2007 .

[13]  M. Goldsworthy,et al.  Optimisation of a desiccant cooling system design with indirect evaporative cooler , 2011 .

[14]  Mohammad. Rasul,et al.  Review on Renewable Energy Potential in Australian Subtropical Region (Central and North Queensland) , 2011 .

[15]  Ursula Eicker,et al.  Design and performance of solar powered absorption cooling systems in office buildings , 2009 .

[16]  Hal Turton,et al.  Greenhouse Gas Emissions in Industrialized Countries: Where Does Australia Stand? , 2004 .

[17]  Giuseppe Starace,et al.  An advanced analytical model of the Diffusion Absorption Refrigerator cycle , 2012 .

[18]  Ruzhu Wang,et al.  Case study and theoretical analysis of a solar driven two-stage rotary desiccant cooling system assisted by vapor compression air-conditioning , 2011 .

[19]  Ruzhu Wang,et al.  Experimental investigations on desiccant wheels , 2012 .

[20]  Yunfei Dai,et al.  Case study of a two-stage rotary desiccant cooling/heating system driven by evacuated glass tube solar air collectors , 2012 .

[21]  Ruzhu Wang,et al.  Analysis on a hybrid desiccant air-conditioning system , 2006 .

[22]  Hongxing Yang,et al.  Investigation on air-conditioning load profile and energy consumption of desiccant cooling system for commercial buildings in Hong Kong , 2012 .

[23]  Irene P. Koronaki,et al.  Experimental assessment and thermodynamic analysis of a solar desiccant cooling system , 2013 .

[24]  Mohammad Masud Kamal. Khan,et al.  Analysis of solar desiccant cooling system for an institutional building in subtropical Queensland, Australia , 2012 .

[25]  Paul Kohlenbach,et al.  Indoor temperature variations resulting from solar desiccant cooling in a building without thermal backup , 2009 .

[26]  Hal Levin Critical Building Design Factors for Indoor Air Quality and Climate: Current Status and Predicted Trends , 1991 .

[27]  Kamel Ghali Energy savings potential of a hybrid desiccant dehumidification air conditioning system in Beirut , 2008 .