Development of a low-cost, 11 µm spectral domain optical coherence tomography surface profilometry prototype

A spectral-domain Optical Coherence Tomography (OCT) surface profilometry prototype has been developed for the purpose of surface metrology of optical elements. The prototype consists of a light source, spectral interferometer, sample fixture and software currently running on Microsoft® Windows platforms. In this system, a broadband light emitting diode beam is focused into a Michelson interferometer with a plane mirror as its sample fixture. At the interferometer output, spectral interferograms of broadband sources were measured using a Czerny-Turner mount monochromator with a 2048-element complementary metal oxide semiconductor linear array as the detector. The software performs importation and interpolation of interferometer spectra to pre-condition the data for image computation. One dimensional axial OCT images were computed by Fourier transformation of the measured spectra. A first reflection surface profilometry (FRSP) algorithm was then formulated to perform imaging of step-function-surfaced samples. The algorithm re-constructs two dimensional colour-scaled slice images by concatenation of 21 and 13 axial scans to form a 10 mm and 3.0 mm slice respectively. Measured spectral interferograms, computed interference fringe signals and depth reflectivity profiles were comparable to simulations and correlated to displacements of a single reflector linearly translated about the arm null-mismatch point. Surface profile images of a double-step-function-surfaced sample, embedded with inclination and crack detail were plotted with an axial resolution of 11 μm. The surface shape, defects and misalignment relative to the incident beam were detected to the order of a micron, confirming high resolution of the developed system as compared to electro-mechanical surface profilometry techniques.

[1]  J. Izatt,et al.  2 Theory of Optical Coherence Tomography , 2014 .

[2]  Randy Wayne Light and video microscopy , 2008 .

[3]  Emily J. McDowell,et al.  Methods and application areas of endoscopic optical coherence tomography. , 2006, Journal of biomedical optics.

[4]  J. Izatt,et al.  Swept source optical coherence tomography using an all-fiber 1300-nm ring laser source. , 2005, Journal of biomedical optics.

[5]  Adrian Bradu,et al.  Integral ceramic superstructure evaluation using time domain optical coherence tomography , 2014, Photonics West - Biomedical Optics.

[6]  James G. Fujimoto,et al.  Optical Coherence Tomography: Introduction , 2001 .

[7]  J. Fujimoto,et al.  Optical coherence tomography: an emerging technology for biomedical imaging and optical biopsy. , 2000, Neoplasia.

[8]  Hiroshi Mashimo,et al.  Endoscopic Optical Coherence Tomography for Clinical Gastroenterology , 2014, Diagnostics.

[9]  James G. Fujimoto,et al.  Design and performance of broadly tunable, narrow line-width, high repetition rate 1310nm VCSELs for swept source optical coherence tomography , 2012, Photonics West - Optoelectronic Materials and Devices.

[10]  Mihir S. Wagh,et al.  Endoscopic Optical Coherence Tomography (OCT): Advances in Gastrointestinal Imaging , 2014, Gastroenterology research and practice.

[11]  D. Kane,et al.  Common-path interferometer for frequency-domain optical coherence tomography. , 2003, Applied optics.

[12]  P. Buah-Bassuah,et al.  Propagation characteristics control by variation of PCF structural parameters , 2014 .

[13]  Fan Lu,et al.  The role of axial resolution of optical coherence tomography on the measurement of corneal and epithelial thicknesses. , 2013, Investigative ophthalmology & visual science.

[14]  Joseph M. Schmitt,et al.  Optical coherence tomography (OCT): a review , 1999 .

[15]  S. Yun,et al.  High-speed spectral-domain optical coherence tomography at 1.3 mum wavelength. , 2003, Optics express.

[16]  J. Duker,et al.  Optical coherence tomography – current and future applications , 2013, Current Opinion in Ophthalmology.

[17]  J. Welzel Optical coherence tomography in dermatology: a review , 2001, Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging.

[18]  James G. Fujimoto Biomedical imaging using optical coherence tomography , 1998, Technical Digest. Summaries of Papers Presented at the International Quantum Electronics Conference. Conference Edition. 1998 Technical Digest Series, Vol.7 (IEEE Cat. No.98CH36236).

[19]  D. Jayas,et al.  Optical coherence tomography imaging , 2015 .

[20]  Freddy T. Nguyen,et al.  Optical coherence tomography: a review of clinical development from bench to bedside. , 2007, Journal of biomedical optics.

[21]  G. Ripandelli,et al.  Optical coherence tomography. , 1998, Seminars in ophthalmology.

[22]  J. Nicholson Advances in Femtosecond Fiber Lasers , 2007, OFC/NFOEC 2007 - 2007 Conference on Optical Fiber Communication and the National Fiber Optic Engineers Conference.

[23]  Hiroshi Ishikawa,et al.  Optical coherence tomography: history, current status, and laboratory work. , 2011, Investigative ophthalmology & visual science.

[24]  D. Sampson,et al.  Semiconductor line source for low-coherence interferometry. , 2001, Applied optics.

[25]  J. Fujimoto,et al.  Ultrahigh speed spectral / Fourier domain OCT ophthalmic imaging at 70,000 to 312,500 axial scans per second. , 2008, Optics express.

[26]  Stephen J. Wolf,et al.  Sub-50 fs pulses around 2070 nm from a synchronously-pumped, degenerate OPO. , 2012, Optics express.

[27]  Jennifer K. Barton,et al.  USING OPTICAL COHERENCE TOMOGRAPHY TO EXAMINE THE SUBSURFACE MORPHOLOGY OF CHINESE GLAZES , 2008 .

[28]  G. Wild,et al.  Modeling of low coherence interferometry using broadband multi-Gaussian light sources , 2012 .

[29]  Jennifer K Barton,et al.  Application of optical coherence tomography to automated contact lens metrology. , 2010, Journal of biomedical optics.