MRMPlus: an open source quality control and assessment tool for SRM/MRM assay development

BackgroundSelected and multiple reaction monitoring involves monitoring a multiplexed assay of proteotypic peptides and associated transitions in mass spectrometry runs. To describe peptide and associated transitions as stable, quantifiable, and reproducible representatives of proteins of interest, experimental and analytical validation is required. However, inadequate and disparate analytical tools and validation methods predispose assay performance measures to errors and inconsistencies.ResultsImplemented as a freely available, open-source tool in the platform independent Java programing language, MRMPlus computes analytical measures as recommended recently by the Clinical Proteomics Tumor Analysis Consortium Assay Development Working Group for “Tier 2” assays – that is, non-clinical assays sufficient enough to measure changes due to both biological and experimental perturbations. Computed measures include; limit of detection, lower limit of quantification, linearity, carry-over, partial validation of specificity, and upper limit of quantification.ConclusionsMRMPlus streamlines assay development analytical workflow and therefore minimizes error predisposition. MRMPlus may also be used for performance estimation for targeted assays not described by the Assay Development Working Group. MRMPlus’ source codes and compiled binaries can be freely downloaded from https://bitbucket.org/paiyetan/mrmplusgui and https://bitbucket.org/paiyetan/mrmplusgui/downloads respectively.

[1]  Nichole L. King,et al.  Targeted Quantitative Analysis of Streptococcus pyogenes Virulence Factors by Multiple Reaction Monitoring*S , 2008, Molecular & Cellular Proteomics.

[2]  H. Christofk,et al.  A label‐free quantification method by MS/MS TIC compared to SILAC and spectral counting in a proteomics screen , 2008, Proteomics.

[3]  Brendan MacLean,et al.  CPTAC Assay Portal: a repository of targeted proteomic assays , 2014, Nature Methods.

[4]  Stefani N. Thomas,et al.  Multiplexed Targeted Mass Spectrometry-Based Assays for the Quantification of N-Linked Glycosite-Containing Peptides in Serum. , 2015, Analytical chemistry.

[5]  K. Parker,et al.  Multiplexed Protein Quantitation in Saccharomyces cerevisiae Using Amine-reactive Isobaric Tagging Reagents*S , 2004, Molecular & Cellular Proteomics.

[6]  S. Gygi,et al.  Quantitative analysis of complex protein mixtures using isotope-coded affinity tags , 1999, Nature Biotechnology.

[7]  R. Cooks,et al.  Multiple reaction monitoring in mass spectrometry/mass spectrometry for direct analysis of complex mixtures , 1978 .

[8]  Susan E. Abbatiello,et al.  Targeted Peptide Measurements in Biology and Medicine: Best Practices for Mass Spectrometry-based Assay Development Using a Fit-for-Purpose Approach* , 2014, Molecular & Cellular Proteomics.

[9]  J. Yates,et al.  Large-scale analysis of the yeast proteome by multidimensional protein identification technology , 2001, Nature Biotechnology.

[10]  Deepak R. Mani,et al.  Statistical characterization of multiple-reaction monitoring mass spectrometry (MRM-MS) assays for quantitative proteomics , 2012, BMC Bioinformatics.

[11]  Brendan MacLean,et al.  Bioinformatics Applications Note Gene Expression Skyline: an Open Source Document Editor for Creating and Analyzing Targeted Proteomics Experiments , 2022 .

[12]  C. Bessant,et al.  Free computational resources for designing selected reaction monitoring transitions , 2010, Proteomics.

[13]  Lisa M. Chung,et al.  Review of software tools for design and analysis of large scale MRM proteomic datasets. , 2013, Methods.

[14]  R. Aebersold,et al.  Mass Spectrometry and Protein Analysis , 2006, Science.

[15]  Richard D. Smith,et al.  Advancing the sensitivity of selected reaction monitoring‐based targeted quantitative proteomics , 2012, Proteomics.

[16]  Ruedi Aebersold,et al.  Mass spectrometry based targeted protein quantification: methods and applications. , 2009, Journal of proteome research.

[17]  M. Ünlü,et al.  Difference gel electrophoresis. A single gel method for detecting changes in protein extracts , 1997, Electrophoresis.

[18]  R. Aebersold,et al.  Selected reaction monitoring–based proteomics: workflows, potential, pitfalls and future directions , 2012, Nature Methods.

[19]  D. Liebler,et al.  Targeted Quantitation of Proteins by Mass Spectrometry , 2013, Biochemistry.

[20]  R. Aebersold,et al.  Selected reaction monitoring for quantitative proteomics: a tutorial , 2008, Molecular systems biology.

[21]  M. Mann,et al.  Stable Isotope Labeling by Amino Acids in Cell Culture, SILAC, as a Simple and Accurate Approach to Expression Proteomics* , 2002, Molecular & Cellular Proteomics.

[22]  Derek J. Bailey,et al.  Parallel Reaction Monitoring for High Resolution and High Mass Accuracy Quantitative, Targeted Proteomics* , 2012, Molecular & Cellular Proteomics.

[23]  Robert L. Moritz,et al.  An assessment of current bioinformatic solutions for analyzing LC‐MS data acquired by selected reaction monitoring technology , 2012, Proteomics.

[24]  Brendan MacLean,et al.  Panorama: A Targeted Proteomics Knowledge Base , 2014, Journal of proteome research.