An indoor experimental investigation of the thermal performance of a TPLT-based natural circulation steam generator as applied to PTC systems

Abstract An indoor experimental setup of a two-phase loop thermosyphon (TPLT)-based natural circulation steam generator, as applied to parabolic trough solar collector for medium temperature steam generation was proposed. Thermal performance of the TPLT steam generation system, especially the receiver, was investigated experimentally. Relatively low two–phase heat transfer coefficients, 263.03 and 265.03 W/m 2  K for two selected steam discharging pressures, were obtained in the receiver for such horizontally-arranged TPLT system. Two types of flow instability, i.e., backflow and bi-directional flow, were observed in the TPLT system. The effects of flow instability on thermal performance of the TPLT steam generation system were analyzed. The results showed that isothermality of the system could be improved due to the presence of both unstable flow conditions. The improved isothermality, however, finally resulted in a lower thermal efficiency. At the steam discharging pressure of 0.15 MPa, heat transfer coefficient was increased by 20.07% and was decreased by 0.40% for the bi-directional flow and backflow patterns, respectively.

[1]  Rahmatollah Khodabandeh Pressure drop in riser and evaporator in an advanced two-phase thermosyphon loop , 2005 .

[2]  Z. T. Yu,et al.  Investigation and analysis on a cellular heat pipe flat solar heater , 2005 .

[3]  S. Kandlikar A General Correlation for Saturated Two-Phase Flow Boiling Heat Transfer Inside Horizontal and Vertical Tubes , 1990 .

[4]  Markus Eck,et al.  Direct steam generation in parabolic troughs: Final results and conclusions of the DISS project , 2004 .

[5]  S. D. Probert,et al.  Natural-circulation solar-energy stimulated systems for heating water , 1982 .

[6]  Yu-Wei Chang,et al.  Heat pipe for cooling of electronic equipment , 2008 .

[7]  Rahmatollah Khodabandeh,et al.  Thermal performance of a closed advanced two-phase thermosyphon loop for cooling of radio base stations at different operating conditions , 2004 .

[8]  Rahmatollah Khodabandeh,et al.  Heat transfer, flow regime and instability of a nano- and micro-porous structure evaporator in a two-phase thermosyphon loop , 2010 .

[9]  Hong Zhang,et al.  Research, development and industrial application of heat pipe technology in China , 2003 .

[10]  Shyy Woei Chang,et al.  Sub-atmospheric boiling heat transfer and thermal performance of two-phase loop thermosyphon , 2012 .

[11]  Markus Eck,et al.  The DISS Project: Direct Steam Generation in Parabolic Trough Systems. Operation and Maintenance Experience and Update on Project Status , 2001 .

[12]  A. El Fadar,et al.  Study of a new solar adsorption refrigerator powered by a parabolic trough collector , 2009 .

[13]  Qunzhi Zhu,et al.  Application of aqueous nanofluids in a horizontal mesh heat pipe , 2011 .

[14]  W. Srimuang,et al.  A review of the applications of heat pipe heat exchangers for heat recovery , 2012 .

[15]  Lounes Tadrist,et al.  Review on two-phase flow instabilities in narrow spaces , 2007 .

[16]  D. Mills Advances in solar thermal electricity technology , 2004 .

[17]  M. Eickhoff,et al.  Applied research concerning the direct steam generation in parabolic troughs , 2003 .

[18]  Igor Pioro,et al.  Industrial two-phase thermosyphons , 1997 .

[19]  Vassilis Belessiotis,et al.  A new heat-pipe type solar domestic hot water system , 2002 .

[20]  M. Pérez-García,et al.  Study of an adsorption refrigeration system powered by parabolic trough collector and coupled with a heat pipe , 2009 .

[21]  Wujun Wang,et al.  An experimental investigation of a natural circulation heat pipe system applied to a parabolic trough solar collector steam generation system , 2012 .

[22]  Sadik Kakaç,et al.  A Review of two-phase flow dynamic instabilities in tube boiling systems , 2008 .

[23]  Rahmatollah Khodabandeh,et al.  An Experimental Investigation of the Influence of System Pressure on the Boiling Heat Transfer Coefficient in a Closed Two-Phase Thermosyphon Loop , 2002 .

[24]  Yu. F. Maidanik,et al.  Miniature loop heat pipes for electronics cooling , 2003 .

[25]  Johann Stichlmair,et al.  Characteristics of thermosiphon reboilers , 2001 .

[26]  Vadim Tsoi,et al.  Thermal performance of plate-type loop thermosyphon at sub-atmospheric pressures , 2011 .

[27]  Eckhard Lüpfert,et al.  Advances in Parabolic Trough Solar Power Technology , 2002 .

[28]  Janusz T. Cieśliński,et al.  Heat transfer characteristics of a two-phase thermosyphon heat exchanger , 2013 .

[29]  J. Thome,et al.  Convective Boiling and Condensation , 1972 .

[30]  K. N. Sheeba,et al.  Experimental studies on heat transfer and friction factor characteristics of thermosyphon solar water heater system fitted with spacer at the trailing edge of twisted tapes , 2009 .

[31]  Rahmatollah Khodabandeh Heat transfer in the evaporator of an advanced two-phase thermosyphon loop , 2005 .

[32]  Leonard L. Vasiliev,et al.  Heat pipes in modern heat exchangers , 2005 .

[33]  Rahmatollah Khodabandeh,et al.  Instability, heat transfer and flow regime in a two-phase flow thermosyphon loop at different diameter evaporator channel , 2010 .

[34]  S. H. Noie-Baghban,et al.  Waste heat recovery using heat pipe heat exchanger (HPHE) for surgery rooms in hospitals , 2000 .