Comparing radiation treatments using intensity-modulated beams, multiple arcs, and single arcs.

PURPOSE A dosimetric comparison of multiple static-field intensity-modulated radiation therapy (IMRT), multiarc intensity-modulated arc therapy (IMAT), and single-arc arc-modulated radiation therapy (AMRT) was performed to evaluate their clinical advantages and shortcomings. METHODS AND MATERIALS Twelve cases were selected for this study, including three head-and-neck, three brain, three lung, and three prostate cases. An IMRT, IMAT, and AMRT plan was generated for each of the cases, with clinically relevant planning constraints. For a fair comparison, the same parameters were used for the IMRT, IMAT, and AMRT planning for each patient. RESULTS Multiarc IMAT provided the best plan quality, while single-arc AMRT achieved dose distributions comparable to those of IMRT, especially in the complicated head-and-neck and brain cases. Both AMRT and IMAT showed effective normal tissue sparing without compromising target coverage and delivered a lower total dose to the surrounding normal tissues in some cases. CONCLUSIONS IMAT provides the most uniform and conformal dose distributions, especially for the cases with large and complex targets, but with a delivery time similar to that of IMRT; whereas AMRT achieves results comparable to IMRT with significantly faster treatment delivery.

[1]  Karl Otto,et al.  Volumetric modulated arc therapy: IMRT in a single gantry arc. , 2007, Medical physics.

[2]  Shahid A Naqvi,et al.  Convolution/superposition using the Monte Carlo method. , 2003, Physics in medicine and biology.

[3]  Cedric X. Yu,et al.  Intensity-modulated arc therapy with dynamic multileaf collimation: an alternative to tomotherapy. , 1995, Physics in medicine and biology.

[4]  Cedric X. Yu,et al.  Leaf-sequencing for intensity-modulated arc therapy using graph algorithms. , 2007, Medical physics.

[5]  J O Deasy,et al.  Tomotherapy: a new concept for the delivery of dynamic conformal radiotherapy. , 1993, Medical physics.

[6]  Uwe Oelfke,et al.  Development of an optimization concept for arc-modulated cone beam therapy. , 2007, Physics in medicine and biology.

[7]  Shuang Luan,et al.  Stochastic versus deterministic kernel-based superposition approaches for dose calculation of intensity-modulated arcs. , 2008, Physics in medicine and biology.

[8]  C Cameron,et al.  Sweeping-window arc therapy: an implementation of rotational IMRT with automatic beam-weight calculation , 2005, Physics in medicine and biology.

[9]  Daliang Cao,et al.  Comparison of plan quality provided by intensity-modulated arc therapy and helical tomotherapy. , 2007, International journal of radiation oncology, biology, physics.

[10]  D M Shepard,et al.  Direct aperture optimization: a turnkey solution for step-and-shoot IMRT. , 2002, Medical physics.

[11]  Shuang Luan,et al.  Converting Multiple-Arc Intensity Modulated Arc Therapy Into a Single Arc for Efficient Delivery , 2007 .

[12]  Cedric X. Yu,et al.  Arc-modulated radiation therapy (AMRT): a single-arc form of intensity-modulated arc therapy , 2008, Physics in medicine and biology.