Evaluation of renal function with 99mTc-MAG3 using semiautomated regions of interest.

UNLABELLED The need to draw regions of interest (ROIs) manually may reduce the convenience and reliability of estimating renal function from renal scintigraphy. We developed a semiautomated method to define ROIs for renal scintigraphy with 99mTc-mercaptoacetyltriglycine (MAG3) and evaluated the clinical applicability of the method to the estimation of renal function by camera-based methods. METHODS Dynamic renal scintigraphy with 99mTc-MAG3 was performed on 21 patients. An operator placed a large rectangular ROI over each kidney, a circular ROI within the liver, and a rectangular ROI between the kidneys. Using these ROIs, semiautomated renal ROIs were determined on the basis of the temporal changes in counts, in addition to the absolute counts, and a subrenal background ROI was automatically assigned for each renal ROI. Background-subtracted renograms were generated using these renal and subrenal ROIs, and renogram parameters were derived from the slope of the renogram and the area under the renogram. Clearance was calculated using the renogram parameters and equations determined previously with manual ROIs and correlated with clearance measured by a single-sample method. The relative function of the right kidney determined by the semiautomated method was compared with that determined by the manual method. Data processing was performed independently by another operator to assess interoperator reproducibility. RESULTS ROIs defined by the semiautomated method were visually judged to be acceptable for clinical use in all patients with a wide range of renal function. Clearance was successfully predicted with the semiautomated ROIs (r = 0.968 using the slope of the renogram; r = 0.934 using the area under the renogram), and relative function calculated with the semiautomated ROIs was almost identical to that calculated with manual ROIs. There was almost complete concordance in absolute and relative function between the two operators. CONCLUSION The semiautomated method can define ROIs for 99mTc-MAG3 renal scintigraphy with limited operator intervention. Camera-based methods using the semiautomated ROIs allow estimation of renal function with high accuracy and little interoperator variability and are suggested to be suitable for clinical use.

[1]  T. Koyanagi,et al.  Quantification of renal function with a count-based gamma camera method using technetium-99m-MAG3 in children. , 1996, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[2]  A S Houston,et al.  An assessment of two methods for generating automatic regions of interest. , 1998, Nuclear medicine communications.

[3]  G. Schwartz,et al.  Geometric method for measuring body surface area: a height-weight formula validated in infants, children, and adults. , 1978, The Journal of pediatrics.

[4]  Ernest V. Garcia,et al.  Measuring technetium-99m-MAG3 clearance with an improved camera-based method. , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[5]  H. Yamagishi,et al.  A trial of automatic kidney detection in a dynamic renal study. , 1987, Radioisotopes.

[6]  Helmar Bergmann,et al.  Relative renal uptake and transit time measurements using functional factor images and fuzzy regions of interest , 1997, European Journal of Nuclear Medicine.

[7]  Comparative study of renal scintigraphy with 99Tcm-mercaptoacetyltriglycine and 123I-orthoiodohippurate. , 1993, Nuclear medicine communications.

[8]  K. Ohtomo,et al.  Evaluation of renal function from 99mTc-MAG3 renography without blood sampling. , 1999, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[9]  G. Granerus,et al.  Subtraction of extra-renal background in 99mTc-DTPA renography: comparison of various regions of interest. , 1992, Clinical physiology.

[10]  I G Zubal,et al.  Compartmental analysis of the complete dynamic scan data for scintigraphic determination of effective renal plasma flow. , 1997, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[11]  P Hannequin,et al.  Cluster analysis for automatic image segmentation in dynamic scintigraphies , 1990, Nuclear medicine communications.

[12]  H. Kitamura,et al.  Noninvasive measurement of renal function with 99mTc-MAG3 gamma-camera renography based on the one-compartment model. , 1998, Clinical nephrology.

[13]  F. Datz,et al.  Comparison of methods for calculating glomerular filtration rate: technetium-99m-DTPA scintigraphic analysis, protein-free and whole-plasma clearance of technetium-99m-DTPA and iodine-125-iothalamate clearance. , 1990, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[14]  M. Lythgoe,et al.  Assessment of various parameters in the estimation of differential renal function using technetium-99m mercaptoacetyltriglycine , 1999, European Journal of Nuclear Medicine.

[15]  R. Folks,et al.  Background subtraction in technetium-99m-MAG3 renography. , 1997, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[16]  A S Houston,et al.  Intra- and interoperator variations in region-of-interest drawing and their effect on the measurement of glomerular filtration rates. , 1999, Clinical nuclear medicine.

[17]  A. Todd-Pokropek,et al.  Appropriate selection of background for 99Tcm-DTPA renography. , 1988, Nuclear medicine communications.

[18]  K. P. Barefield,et al.  Improved formulas for the estimation of renal depth in adults. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[19]  B. Kemp,et al.  Multicenter trial validation of a camera-based method to measure Tc-99m mercaptoacetyltriglycine, or Tc-99m MAG3, clearance. , 1997, Radiology.