Real‐time three‐dimensional fetal echocardiography: initial feasibility study.

Real‐time three‐dimensional echocardiography acquires data as a volume rather than as a series of planar images, thereby obviating cardiac or respiratory gating and limiting artifacts generated by random motion. This study was undertaken to evaluate the feasibility of using real‐time three‐dimensional echocardiography to evaluate fetal cardiac anatomy and function. Ten human fetuses were evaluated in utero, four of whom had congenital heart disease. Freehand transabdominal scanning was performed on each pregnant woman using a real‐time three‐dimensional echocardiography system. Four volume clips at 20 volumes/s of duration 1.5 s each were obtained on each fetal heart and stored for off‐line analysis. Data were displayed immediately as a series of four simultaneous planes, with the ability for the observer to manipulate the position of each plane within the acquired volume data set. Cardiac motion could be slowed, stopped, or viewed at its original speed. Most structures and views, as well as cardiac function, could be visualized consistently. Abnormal structures could be detected readily. Off‐line analysis was rapid and easy. We conclude that fetal real‐time three‐dimensional echocardiography is a feasible, facile, and rapid new technique.

[1]  R HEIM DE BALSAC,et al.  [The pulmonary artery]. , 2020, La semaine des hopitaux : organe fonde par l'Association d'enseignement medical des hopitaux de Paris.

[2]  J. E. Snyder,et al.  Real-time orthogonal mode scanning of the heart. I. System design. , 1986, Journal of the American College of Cardiology.

[3]  J. Green,et al.  Fetal echocardiographic screening for congenital heart disease: the importance of the four-chamber view. , 1987, American journal of obstetrics and gynecology.

[4]  Arthur E. Weyman,et al.  Three-dimensional echocardiography. In vivo validation for right ventricular volume and function. , 1994, Circulation.

[5]  D. King,et al.  Three-dimensional echocardiography. Advances for measurement of ventricular volume and mass. , 1994, Hypertension.

[6]  Joni K. Evans,et al.  A randomized trial of prenatal ultrasonographic screening: impact on the detection, management, and outcome of anomalous fetuses. The RADIUS Study Group. , 1994, American journal of obstetrics and gynecology.

[7]  T. Nelson,et al.  Distance and volume measurement using three‐dimensional ultrasonography. , 1995, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[8]  Fetal Echocardiography: Retrospective Review of Clinical Experience and an Evaluation of Indications , 1995, Obstetrics and gynecology.

[9]  E Merz,et al.  Volume scanning in the evaluation of fetal malformations: a new dimension in prenatal diagnosis , 1995, Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology.

[10]  T. Nelson,et al.  In vivo three‐dimensional sonographic measurement of organ volume: validation in the urinary bladder. , 1996, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[11]  T. Nelson,et al.  Three‐dimensional echocardiographic evaluation of fetal heart anatomy and function: acquisition, analysis, and display. , 1996, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[12]  Eric Jauniaux,et al.  Selection and identification of standard cardiac views from three‐dimensional volume scans of the fetal thorax. , 1996 .

[13]  D. Jurkovic,et al.  Selection and identification of standard cardiac views from three-dimensional volume scans of the fetal thorax. , 1996, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[14]  J Deng,et al.  Fetal echocardiography in three and four dimensions. , 1996, Ultrasound in medicine & biology.

[15]  T R Nelson,et al.  Usefulness of gated three-dimensional fetal echocardiography to reconstruct and display structures not visualized with two-dimensional imaging. , 1997, The American journal of cardiology.

[16]  F. Chang,et al.  Fetal heart volume assessment by three‐dimensional ultrasound , 1997, Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology.

[17]  T R Nelson,et al.  Three‐dimensional ultrasonography of normal fetal heart: comparison with two‐dimensional imaging. , 1998, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[18]  T R Nelson,et al.  Three-dimensional fetal echocardiography. , 1998, Progress in biophysics and molecular biology.

[19]  T R Nelson,et al.  Three‐dimensional fetal echocardiography: gated versus nongated techniques. , 1998, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[20]  Chikai J. Ohazama,et al.  Assessment of regional wall motion abnormalities with real-time 3-dimensional echocardiography. , 1999, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[21]  S. Takuma,et al.  Real-time, 3-dimensional echocardiography acquires all standard 2-dimensional images from 2 volume sets: a clinical demonstration in 45 patients. , 1999, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.