Noninvasive Monitoring of Blood Glucose with Raman Spectroscopy.

The successful development of a noninvasive blood glucose sensor that can operate reliably over sustained periods of time has been a much sought after but elusive goal in diabetes management. Since diabetes has no well-established cure, control of elevated glucose levels is critical for avoiding severe secondary health complications in multiple organs including the retina, kidney and vasculature. While fingerstick testing continues to be the mainstay of blood glucose detection, advances in electrochemical sensing-based minimally invasive approaches have opened the door for alternate methods that would considerably improve the quality of life for people with diabetes. In the quest for better sensing approaches, optical technologies have surfaced as attractive candidates as researchers have sought to exploit the endogenous contrast of glucose, notably its absorption, scattering, and polarization properties. Vibrational spectroscopy, especially spontaneous Raman scattering, has exhibited substantial promise due to its exquisite molecular specificity and minimal interference of water in the spectral profiles acquired from the blood-tissue matrix. Yet, it has hitherto been challenging to leverage the Raman scattering signatures of glucose for prediction in all but the most basic studies and under the least demanding conditions. In this Account, we discuss the newly developed array of methodologies that address the key challenges in measuring blood glucose accurately using Raman spectroscopy and unlock new prospects for translation to sustained noninvasive measurements in people with diabetes. Owing to the weak intensity of spontaneous Raman scattering, recent research has focused on enhancement of signals from the blood constituents by designing novel excitation-collection geometries and tissue modulation methods while our attempts have led to the incorporation of nonimaging optical elements. Additionally, invoking mass transfer modeling into chemometric algorithms has not only addressed the physiological lag between the actual blood glucose and the measured interstitial fluid glucose values but also offered a powerful tool for predictive measurements of hypoglycemia. This framework has recently been extended to provide longitudinal tracking of glucose concentration without necessitating extensive a priori concentration information. These findings are advanced by the results of recent glucose tolerance studies in human subjects, which also hint at the need for designing nonlinear calibration models that can account for subject-to-subject variations in skin heterogeneity and hematocrit levels. Together, the emerging evidence underscores the promise of a blood withdrawal-free optical platform-featuring a combination of high-throughput Raman spectroscopic instrumentation and data analysis of subtle variations in spectral expression-for diabetes screening in the clinic and, ultimately, for personalized monitoring.

[1]  Yukihiro Ozaki,et al.  Sequential identification of model parameters by derivative double two-dimensional correlation spectroscopy and calibration-free approach for chemical reaction systems. , 2012, Analytical chemistry.

[2]  O. Khalil,et al.  Non-invasive glucose measurement technologies: an update from 1999 to the dawn of the new millennium. , 2004, Diabetes technology & therapeutics.

[3]  C. Saudek,et al.  Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor. , 2003, Diabetes.

[4]  M. Strano,et al.  Near-infrared optical sensors based on single-walled carbon nanotubes , 2004, Nature materials.

[5]  Gary L Horowitz,et al.  Emerging trends in optical sensing of glycemic markers for diabetes monitoring. , 2015, Trends in analytical chemistry : TRAC.

[6]  R. V. Van Duyne,et al.  Bisboronic Acids for Selective, Physiologically Relevant Direct Glucose Sensing with Surface-Enhanced Raman Spectroscopy. , 2016, Journal of the American Chemical Society.

[7]  Mark A Arnold,et al.  In vivo near-infrared spectroscopy of rat skin tissue with varying blood glucose levels , 2004, SPIE BiOS.

[8]  Anthony G A Aggidis,et al.  Investigating pipeline and state of the art blood glucose biosensors to formulate next steps. , 2015, Biosensors & bioelectronics.

[9]  M. Feld,et al.  Multicomponent blood analysis by near-infrared Raman spectroscopy. , 1999, Applied optics.

[10]  Adam Heller,et al.  Electrochemistry in diabetes management. , 2010, Accounts of chemical research.

[11]  D. A. Stuart,et al.  In vivo glucose measurement by surface-enhanced Raman spectroscopy. , 2006, Analytical chemistry.

[12]  Michael S Feld,et al.  Optical fiber probe for biomedical Raman spectroscopy. , 2004, Applied optics.

[13]  Michael D. Morris,et al.  Emerging Raman applications and techniques in biomedical and pharmaceutical fields , 2010 .

[14]  Wei-Chuan Shih,et al.  Intrinsic Raman spectroscopy for quantitative biological spectroscopy part I: theory and simulations. , 2008, Optics express.

[15]  M. Feld,et al.  Blood analysis by Raman spectroscopy. , 2002, Optics letters.

[16]  Corinna Cortes,et al.  Support-Vector Networks , 1995, Machine Learning.

[17]  Shoji Takeuchi,et al.  Injectable hydrogel microbeads for fluorescence-based in vivo continuous glucose monitoring , 2010, Proceedings of the National Academy of Sciences.

[18]  Michael S Feld,et al.  A novel non-imaging optics based Raman spectroscopy device for transdermal blood analyte measurement. , 2011, AIP advances.

[19]  Wolfgang Petrich,et al.  Quantitative analysis of serum and serum ultrafiltrate by means of Raman spectroscopy. , 2004, The Analyst.

[20]  M A Arnold,et al.  Phantom glucose calibration models from simulated noninvasive human near-infrared spectra. , 1998, Analytical chemistry.

[21]  D. Liepmann,et al.  A microneedle-based glucose monitor: fabricated on a wafer-level using in-device enzyme immobilization , 2003, TRANSDUCERS '03. 12th International Conference on Solid-State Sensors, Actuators and Microsystems. Digest of Technical Papers (Cat. No.03TH8664).

[22]  R. Dasari,et al.  Effect of photobleaching on calibration model development in biological Raman spectroscopy. , 2011, Journal of biomedical optics.

[23]  Michael S Feld,et al.  Development of robust calibration models using support vector machines for spectroscopic monitoring of blood glucose. , 2010, Analytical chemistry.

[24]  C. MacAulay,et al.  The Dynamics of Laser‐Induced Changes in Human Skin Autofluorescence—Experimental Measurements and Theoretical Modeling , 1998, Photochemistry and photobiology.

[25]  George Shaheen,et al.  Instrument for near infrared emission spectroscopic probing of human fingertips in vivo. , 2010, The Review of scientific instruments.

[26]  Michael S Feld,et al.  Wavelength selection-based nonlinear calibration for transcutaneous blood glucose sensing using Raman spectroscopy. , 2011, Journal of biomedical optics.

[27]  N. Ramanujam,et al.  Development of a Fiber Optic Probe to Measure NIR Raman Spectra of Cervical Tissue In Vivo , 1998, Photochemistry and photobiology.

[28]  Richard P Van Duyne,et al.  In vivo, transcutaneous glucose sensing using surface-enhanced spatially offset Raman spectroscopy: multiple rats, improved hypoglycemic accuracy, low incident power, and continuous monitoring for greater than 17 days. , 2011, Analytical chemistry.

[29]  H. Heise,et al.  Noninvasive blood glucose sensors based on near-infrared spectroscopy. , 1994, Artificial organs.

[30]  Obrad R Sćepanović,et al.  Detection of morphological markers of vulnerable atherosclerotic plaque using multimodal spectroscopy. , 2006, Journal of biomedical optics.

[31]  R. Dasari,et al.  Investigation of the specificity of Raman spectroscopy in non-invasive blood glucose measurements , 2011, Analytical and bioanalytical chemistry.

[32]  Jingwei Shao,et al.  In Vivo Blood Glucose Quantification Using Raman Spectroscopy , 2012, PloS one.

[33]  J. Westerhuis,et al.  Quantitative Raman reaction monitoring using the solvent as internal standard. , 2005, Analytical chemistry.

[34]  Samir Mitragotri,et al.  Transdermal monitoring of glucose and other analytes using ultrasound , 2000, Nature Medicine.

[35]  M. Feld,et al.  Raman spectroscopy for noninvasive glucose measurements. , 2005, Journal of biomedical optics.

[36]  Michael S Feld,et al.  Turbidity-corrected Raman spectroscopy for blood analyte detection. , 2009, Analytical chemistry.

[37]  Hervé Rigneault,et al.  Kagome hollow-core photonic crystal fiber probe for Raman spectroscopy. , 2012, Optics letters.

[38]  Wei-Chuan Shih,et al.  Determination of uncertainty in parameters extracted from single spectroscopic measurements. , 2007, Journal of biomedical optics.

[39]  R. Dasari,et al.  Compound parabolic concentrator probe for efficient light collection in spectroscopy of biological tissue. , 1996, Applied optics.

[40]  R. Dasari,et al.  Accurate spectroscopic calibration for noninvasive glucose monitoring by modeling the physiological glucose dynamics. , 2010, Analytical chemistry.

[41]  Michael S Strano,et al.  Single Walled Carbon Nanotubes as Reporters for the Optical Detection of Glucose , 2009, Journal of diabetes science and technology.

[42]  Yukihiro Ozaki,et al.  Spectroscopic approach for dynamic bioanalyte tracking with minimal concentration information , 2014, Scientific Reports.

[43]  Gajendra Pratap Singh,et al.  Investigation of noise-induced instabilities in quantitative biological spectroscopy and its implications for noninvasive glucose monitoring. , 2012, Analytical chemistry.

[44]  R. Bhargava,et al.  Chemometric Methods for Biomedical Raman Spectroscopy and Imaging , 2010 .

[45]  S. K. Vashist Non-invasive glucose monitoring technology in diabetes management: a review. , 2012, Analytica chimica acta.

[46]  James L Lambert,et al.  Glucose determination in human aqueous humor with Raman spectroscopy. , 2005, Journal of biomedical optics.