Accuracy improvement of large area flexible piezoresistive digital tactile array sensing system

Piezoresistive tactile array represent an important tool for pressure distribution analysis. Each site of the matrix acts as variable resistance whose value varies with normal force. A 16 times 16 array of fixed resistances has been realized to simulate the static response of 3.7 times 3.7 cm2 size FSR tactile sensors to strain. Scanning the different sites was performed by a microcontroller-based circuitry. To eliminate leak current paths when selecting a site, this latter must be isolated from the resistance grid. In this study three different conditioning circuits have been tested in order to assess the measurement accuracy. Results have shown that accuracy is enhanced in the region of low R when using the isolating circuit in which the output voltage from a selected row is fed back to all columns except the one selected. On the other hand, the accuracy decreases as analog multiplexer Ron increases. At last, transient effects have been observed when scanning the array is conducted at high rate.

[1]  T. D'Alessio Improving the use of force sensing resistors arrays for the measure of hand grasp , 1996, Proceedings of 8th Mediterranean Electrotechnical Conference on Industrial Applications in Power Systems, Computer Science and Telecommunications (MELECON 96).

[2]  D M Brienza,et al.  Seat cushion design for elderly wheelchair users based on minimization of soft tissue deformation using stiffness and pressure measurements. , 1996, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[3]  Emil M. Petriu,et al.  High sampling resolution tactile sensor for object recognition , 1993, 1993 IEEE Instrumentation and Measurement Technology Conference.

[4]  Hideki Yamamoto,et al.  Pressure measurement of air cushions for SCI patients , 2000, IEEE Trans. Instrum. Meas..

[5]  Akihiro Tokuhiro,et al.  Measurement of SCI patient's buttock pressure on wheelchair and bed , 2001, Proceedings of the International Workshop on Intelligent Data Acquisition and Advanced Computing Systems: Technology and Applications. IDAACS'2001 (Cat. No.01EX510).

[6]  T. Kernozek,et al.  Seat interface pressures of individuals with paraplegia: influence of dynamic wheelchair locomotion compared with static seated measurements. , 1998, Archives of physical medicine and rehabilitation.

[7]  D. Walsh,et al.  Impact of sitting time on seat-interface pressure and on pressure mapping with multiple sclerosis patients. , 2005, Archives of physical medicine and rehabilitation.

[8]  Thomas H. Speeter A Tactile Sensing System for Robotic Manipulation , 1990, Int. J. Robotics Res..

[9]  Bert Tise,et al.  A compact high resolution piezoresistive digital tactile sensor , 1988, Proceedings. 1988 IEEE International Conference on Robotics and Automation.

[10]  J. Lima,et al.  A large area force sensor for smart skin applications , 2002, Proceedings of IEEE Sensors.

[11]  John G. Webster,et al.  The Measurement, Instrumentation and Sensors Handbook , 1998 .