Theoretical analysis on ground source heat pump and air source heat pump systems by the concepts of cool and warm exergy

Abstract This study presents exergetic characteristics of both ground source heat pump systems (GSHPs) and air source heat pump systems (ASHPs) based on the concepts of “cool exergy” and “warm exergy”. Quantitative example followed by theoretical analysis shows that GSHPs consume less exergy than ASHPs do. This is because firstly “cool exergy” is obtained from the ground in GSHPs, whereas no “cool exergy” is extracted from the environment by the ASHPs. Secondly, temperature difference between refrigerant via cooling water and ground in GSHPs is smaller than that between refrigerant and air in ASHPs. In the GSHP, cool exergy flows into the cooling water from the ground and then enters the indoor air through the refrigerant cycle. In the ASHP, the refrigerant cycle separates the electricity input of the compressor into “cool exergy” and “warm exergy.” The “cool exergy” enters the indoor air and the “warm exergy” is exhausted to the ambient environment. The analysis also shows that compressor requires largest exergy input among the total exergy inputs, and the exergy consumption in the refrigerant cycle is the highest. Thus, the improvement of the compressor performance to reduce its electricity consumption was confirmed to be of vital in minimizing unnecessary exergy consumption.

[1]  Masanori Shukuya,et al.  EXERGY-ENTROPY PROCESS OF ELECTRIC LIGHTING SYSTEMS USING FLUORESCENT LAMPS , 1996 .

[2]  Masanori Shukuya,et al.  Comparative effects of building envelope improvements and occupant behavioural changes on the exergy consumption for heating and cooling , 2010 .

[3]  Masanori Shukuya Exergy: Theory and Applications in the Built Environment , 2012 .

[4]  Dennis R. Heldman,et al.  Introduction to food engineering , 1984 .

[5]  Arif Hepbasli,et al.  A comparative study on exergetic assessment of two ground-source (geothermal) heat pump systems for residential applications , 2007 .

[6]  Masanori Shukuya,et al.  Exergy concept and its application to the built environment , 2009 .

[7]  Marc A. Rosen,et al.  Geothermal heat pump systems: Status review and comparison with other heating options , 2013 .

[8]  H. Torio,et al.  Development of system concepts for improving the performance of a waste heat district heating network with exergy analysis , 2010 .

[9]  Mateja Dovjak,et al.  Analysis on exergy consumption patterns for space heating in Slovenian buildings , 2010 .

[10]  John W. Lund,et al.  Direct utilization of geothermal energy 2010 worldwide review , 2011 .

[11]  Arif Hepbasli,et al.  A study on modeling and performance assessment of a heat pump system for utilizing low temperature geothermal resources in buildings , 2007 .

[12]  J. E. Ahern,et al.  The exergy method of energy systems analysis , 1980 .

[13]  B. Olesen,et al.  Low temperature heating and high temperature cooling : embedded water based surface heating and cooling systems , 2009 .

[14]  Ibrahim Dincer,et al.  Exergy analysis of two geothermal district heating systems for building applications , 2007 .