The development of new techniques for the detection of homemade explosive devices is an area of intense research for the defense community. Such sensors must exhibit high selectivity to detect explosives and/or explosives related materials in a complex environment. Spectroscopic techniques such as FTIR are capable of discriminating between the volatile components of explosives; however, there is a need for less expensive systems for wide-range use in the field. To tackle this challenge we are investigating the use of multiple, overlapping, broad-band infrared (IR) filters to enable discrimination of volatile chemicals associated with an explosive device from potential background interferants with similar chemical signatures. We present an optical approach for the detection of fuel oil (the volatile component in ammonium nitrate-fuel oil explosives) that relies on IR absorption spectroscopy in a laboratory environment. Our proposed system utilizes a three filter set to separate the IR signals from fuel oil and various background interferants in the sample headspace. Filter responses for the chemical spectra are calculated using a Gaussian filter set. We demonstrate that using a specifically chosen filter set enables discrimination of pure fuel oil, hexanes, and acetone, as well as various mixtures of these components. We examine the effects of varying carrier gasses and humidity on the collected spectra and corresponding filter response. We study the filter response on these mixtures over time as well as present a variety of methods for observing the filter response functions to determine the response of this approach to detecting fuel oil in various environments.
[1]
Humanitarian Demining,et al.
Mine Detection Dogs: Training, Operations and Odour Detection
,
2003
.
[2]
Jas S. Sanghera,et al.
Kromoscopy for detection of chemical warfare agents
,
2004,
SPIE Optics East.
[3]
Michael Krausa,et al.
Vapour and trace detection of explosives for anti-terroism purposes
,
2004
.
[4]
M A Arnold,et al.
Evaluation of Kromoscopy: resolution of glucose and urea.
,
2000,
Applied optics.
[5]
M J Block,et al.
Kromoscopic analysis: a possible alternative to spectroscopic analysis for noninvasive measurement of analytes in vivo.
,
1994,
Clinical chemistry.
[6]
Robert W. Field,et al.
INFRARED ABSORPTION OF EXPLOSIVE MOLECULE VAPORS
,
1997
.
[7]
J. Steinfeld,et al.
Explosives detection: a challenge for physical chemistry.
,
1998,
Annual review of physical chemistry.
[8]
Airat K. Amerov,et al.
Kromoscopic analysis in two- and three-component aqueous solutions of blood constituents
,
2001,
SPIE BiOS.
[9]
L. J. Myers,et al.
The scientific foundation and efficacy of the use of canines as chemical detectors for explosives.
,
2001,
Talanta.