Intensive attention improves glycaemic control in insulin-dependent diabetes without further advantage from home blood glucose monitoring: results of a controlled trial.

Forty-six diabetics treated with twice-daily insulin were seen every two weeks for six months in an intensive education programme aided by regular home urine glucose testing. Control was improved with a decrease in 24-hour urinary glucose excretion (median 138 mmol/24 h (24.8 g/24 h) falling to 70 mmol/24 h (12.6 g/24 h); p less than 0.002), glycosylated haemoglobin concentration (mean 11.4 +/- SD 2.3% falling to 10.4 +/- 1.5%; p less than 0.001), and Diastix score (median 3.0 falling to 1.3; p less than 0.001). There was no reported increase in hypoglycaemia. Thirty-eight of the diabetics proceeded to a nine-month randomised cross-over study of the effect on blood glucose control of monitoring urinary glucose or blood glucose measured visually or by a reflectance meter using appropriate reagent strips. No further improvement in control was observed after home blood glucose monitoring. Nevertheless, 29 out of 37 patients preferred blood to urine glucose monitoring. During both the education and cross-over studies there was evidence of an initial improvement in control followed by deterioration. This was independent of the monitoring method used in the cross-over period and may have been due to waning enthusiasm. Despite patient enthusiasm and other reports to the contrary, home blood glucose monitoring offered no improvement in control over intensive attention and conventional urine glucose monitoring.

[1]  A. Schiffrin,et al.  Comparison Between Continuous Subcutaneous Insulin Infusion and Multiple Injections of Insulin: A One-Year Prospective Study , 1982, Diabetes.

[2]  D. Lezotte,et al.  Comparison of Blood Glucose Testing Using Reagent Strips With and Without a Meter (Chemstrips bG and Dextrostix/Dextrometer) , 1981, Diabetes Care.

[3]  J. Skyler,et al.  Comparison of Methods for Blood Glucose Monitoring , 1981, Diabetes Care.

[4]  K. Alberti,et al.  A Comparison Study of Blood Glucose Test Strips , 1981, Diabetes Care.

[5]  P. Savage,et al.  A Comparison of Accuracy and Estimated Cost of Methods for Home Blood Glucose Monitoring , 1981, Diabetes Care.

[6]  J. Skyler,et al.  Algorithms for Adjustment of Insulin Dosage by Patients Who Monitor Blood Glucose , 1981, Diabetes Care.

[7]  L. Jovanovic,et al.  The clinical utility of glycosylated hemoglobin. , 1981, The American journal of medicine.

[8]  HOME BLOOD-GLUCOSE MONITORING: REVOLUTION, REVELATION, OR RIP-OFF? , 1980, The Lancet.

[9]  J. M. Brudenell,et al.  MANAGEMENT OF THE PREGNANT DIABETIC: HOME OR HOSPITAL, WITH OR WITHOUT GLUCOSE METERS? , 1980, The Lancet.

[10]  R. K. Bernstein Virtually Continuous Euglycemia for 5 Yr in a Labile Juvenile-onset Diabetic Patient Under Noninvasive Closed-Loop Control , 1980, Diabetes Care.

[11]  J. Dudley The Diabetes Educator's Role in Teaching the Diabetic Patient , 1980, Diabetes Care.

[12]  G. Schumacher,et al.  Feasibility of Blood Glucose Self-Monitoring in Unstable Insulin-dependent Diabetes , 1980, Diabetes Care.

[13]  F. Whitehouse,et al.  Teaching the Person with Diabetes: Experience with a Follow-up Session , 1979, Diabetes Care.

[14]  J. Skyler,et al.  Home Blood Glucose Monitoring As an Aid in Diabetes Management , 1978, Diabetes Care.

[15]  J. Pirart Diabetes Mellitus and Its Degenerative Complications: A Prospective Study of 4,400 Patients Observed Between 1947 and 1973 , 1978, Diabetes Care.

[16]  R. Tattersall,et al.  SELF-MONITORING OF BLOOD-GLUCOSE Improvement of Diabetic Control , 1978, The Lancet.

[17]  P. Sönksen,et al.  HOME MONITORING OF BLOOD-GLUCOSE Method for Improving Diabetic Control , 1978, The Lancet.

[18]  P. Raskin Diabetic regulation and its relationship to microangiopathy. , 1978, Metabolism: clinical and experimental.

[19]  T. Danowski,et al.  Jet Injection of Insulin During Self-Monitoring of Blood Glucose , 1978, Diabetes Care.

[20]  A. Rubenstein,et al.  HÆMOGLOBIN A1: AN INDICATOR OF THE METABOLIC CONTROL OF DIABETIC PATIENTS , 1977, The Lancet.

[21]  P. Gallop,et al.  Glycosylated hemoglobins and long-term blood glucose control in diabetes mellitus. , 1977, The Journal of clinical endocrinology and metabolism.

[22]  J. Davidson,et al.  Evaluation of Diabetes Patient-education Programs , 1977, Diabetes.

[23]  K. Winterhalter,et al.  In vitro synthesis of hemoglobin AIc , 1976, FEBS letters.

[24]  A. Cerami,et al.  Correlation of glucose regulation and hemoglobin AIc in diabetes mellitus. , 1976, The New England journal of medicine.

[25]  N. Freinkel,et al.  Control and Diabetes , 1976 .

[26]  J. Assal,et al.  Plasma Lipid Levels in Diabetic Children: Effect of Diet Restricted in Cholesterol and Saturated Fats , 1975, Diabetes.

[27]  R. C. James,et al.  Evaluation of Some Commonly Used Semiquantitative Methods for Urinary Glucose and Ketone Determinations , 1974, Diabetes.

[28]  W. F. Taylor,et al.  Urine Glucose Analyses During Continuous: Blood Glucose Monitoring , 1972 .

[29]  D. Etzwiler,et al.  Evaluation of Programmed Education Among Juvenile Diabetics and Their Families , 1972, Diabetes.

[30]  L. V. Miller,et al.  More efficient care of diabetic patients in a county-hospital setting. , 1972, The New England journal of medicine.

[31]  N. Woolf Diabetes and atherosclerosis. , 1971, Acta diabetologica latina.

[32]  D. Etzwiler,et al.  Comparative Study of Diabetes Knowledge Among Juvenile Diabetics and Their Parents , 1971, Diabetes.

[33]  W. F. Taylor,et al.  Mean Amplitude of Glycemic Excursions, a Measure of Diabetic Instability , 1970, Diabetes.

[34]  D. Etzwiler Who's Teaching the Diabetic? , 1967, Diabetes.

[35]  J. Schlichtkrull,et al.  [M-VALUE, AN INDEX FOR BLOOD SUGAR CONTROL IN DIABETICS]. , 1964, Ugeskrift for laeger.

[36]  S. Beaser Teaching the Diabetic Patient , 1956, Diabetes.

[37]  E. Ryan,et al.  Glycaemic control with intensified conventional therapy , 1981 .

[38]  D. Johnston,et al.  A Comparative Study of Blood Glucose Test Strips , 1981 .

[39]  Symposium on home blood glucose monitoring. , 1980, Diabetes care.

[40]  O. Faber,et al.  Production of antisera to synthetic benzyloxycarbonyl-C-peptide of human proinsulin. , 1976, Hoppe-Seyler's Zeitschrift fur physiologische Chemie.