Dynamic response of a single-phase rectangular natural circulation loop to different excitations of input power

Abstract Dynamic analyses of system responses during sudden change in input power for single-phase natural circulation loops are only a very recent concept. The present study theoretically investigates the transient behaviour of rectangular loops, subjected to direct heat addition and convective cooling. Non-dimensional forms of governing equations have been used alongside suitable closure relations. Three fundamental signals, having step, ramp and exponential profiles, and a newly-defined modified exponential signal have been applied on input power during power increase and decrease. Step and exponential changes have been found to lead the system towards instability during power up-surge, due to the impulsive nature of transition. The system also takes long time to attain steady-state for power decrease to a stable state following a step change. Step signal can be broken into equal increments for better performance. Increasing the number of increments and time-lag between successive steps, higher power operation can be sustained for a longer duration. Modified exponential signal has been found to be superior compared to others, both during power increase and decrease. It allows a moderately increasing gradient during power transients and hence the rate of oscillation growth is much smaller.

[1]  Xin‐Rong Zhang,et al.  Natural convective flow and heat transfer of supercritical CO2 in a rectangular circulation loop , 2010 .

[2]  Walter Ambrosini,et al.  The effect of truncation error on the numerical prediction of linear stability boundaries in a natural circulation single-phase loop , 1998 .

[3]  M. Misale,et al.  Stabilization of a single-phase natural circulation loop by pressure drops , 2001 .

[4]  Eduardo Ramos,et al.  Single-phase natural circulation in a tilted square loop , 1987 .

[5]  Zhong‐sheng Liu,et al.  Effect of heat transfer on the instabilities and transitions of supercritical CO2 flow in a natural circulation loop , 2010 .

[6]  Walter Ambrosini,et al.  Prediction of stability of one-dimensional natural circulation with a low diffusion numerical scheme , 2003 .

[7]  Souvik Bhattacharyya,et al.  Performance comparison of rectangular and toroidal natural circulation loops under steady and transient conditions , 2012 .

[8]  P. Welander On the oscillatory instability of a differentially heated fluid loop , 1967, Journal of Fluid Mechanics.

[9]  Pallippattu Krishnan Vijayan,et al.  Analysis of the unstable behaviour of a single-phase natural circulation loop with one-dimensional and computational fluid-dynamic models , 2007 .

[10]  P. Vijayan,et al.  Steady state and stability characteristics of single-phase natural circulation in a rectangular loop with different heater and cooler orientations , 2007 .

[11]  M. Ram Gopal,et al.  Steady-state analysis of CO2 based natural circulation loops with end heat exchangers , 2009 .

[12]  Souvik Bhattacharyya,et al.  CFD analysis of a CO2 based natural circulation loop with end heat exchangers , 2012 .

[13]  H. F. Creveling,et al.  Stability characteristics of a single-phase free convection loop , 1975, Journal of Fluid Mechanics.

[14]  Eduardo Ramos,et al.  A steady-state analysis for variable area one- and two-phase thermosyphon loops , 1985 .

[15]  Xin‐Rong Zhang,et al.  Simulation of Heat Transfer and System Behavior in a Supercritical CO2 Based Thermosyphon: Effect of Pipe Diameter , 2011 .

[16]  Y. Zvirin,et al.  The instability associated with the onset of motion in a thermosyphon , 1985 .

[17]  Xin-Rong Zhang,et al.  Study of trans-critical CO2 natural convective flow with unsteady heat input and its implications on system control , 2012 .

[18]  Pallippattu Krishnan Vijayan,et al.  Mathematical modelling of the stability characteristics of a natural circulation loop , 1995 .

[19]  Pallippattu Krishnan Vijayan,et al.  Scaling laws for single-phase natural circulation loops , 1994 .

[20]  N. M. Rao,et al.  Dynamic performance of a natural circulation loop with end heat exchangers under different excitations , 2005 .

[21]  N. M. Rao,et al.  Comparison of dynamic performance for direct and fluid coupled indirect heat exchange systems , 2005 .

[22]  P. Garibaldi,et al.  Experiments in a single-phase natural circulation mini-loop , 2007 .

[23]  O. B. Samoilov,et al.  Nuclear district heating plants AST-500. Present status and prospects for future in Russia , 1997 .

[24]  Francesco Saverio D'Auria,et al.  Transient and stability analysis in single-phase natural circulation , 2004 .

[25]  P. Vijayan Experimental observations on the general trends of the steady state and stability behaviour of single-phase natural circulation loops , 2002 .

[26]  Souvik Bhattacharyya,et al.  Influence of geometry and operating parameters on the stability response of single-phase natural circulation loop , 2013 .

[27]  V. Teschendorff,et al.  Simulation of the unstable oscillatory behavior of single-phase natural circulation with repetitive flow reversals in a rectangular loop using the computer code athlet , 1995 .

[28]  Wang Dazhong,et al.  Technical design features and safety analysis of the 200 MWt Nuclear Heating Reactor , 1993 .