METAL MOBILIZATION FROM WATER-DISTRIBUTION SYSTEMS OF BUILDINGS SERVICED BY LEAD-PIPE MAINS

Studies were made of the mobilization of metals from the water-distribution systems within several types of buildings, many of which are serviced by old lead-pipe mains, in Halifax, Nova Scotia. The study examined 36 single-family houses, three apartments in a high-rise building, and one school. In many homes, water that stood in pipes overnight developed relatively large concentrations of copper, lead, and zinc. In total, 70% of the standing water from single-family homes had lead concentrations exceeding the 0.01 mg/L criterion for lead in drinking water. The 30 single-family homes serviced by municipal mains made of lead did not have significantly larger lead concentrations than the six homes serviced by other types of piping. This suggests that the source of lead in drinking water is metal dissolving from the water-distribution systems within the homes, rather than from the lead service lines.

[1]  G. K. Matthew Lead in drinking water and health. , 1981, The Science of the total environment.

[2]  J. Ferguson,et al.  The Effects of Short‐Term Changes in Water Quality on Copper and Zinc Corrosion Rates , 1987 .

[3]  K. S. Subramanian,et al.  A national survey for cadmium, chromium, copper, lead, zinc, calcium, and magnesium in canadian drinking water supplies , 1979 .

[4]  John F. Ferguson,et al.  Corrosion Monitoring and Control in the Pacific Northwest , 1987 .

[5]  E. R. Samuels,et al.  Preliminary studies on the leaching of some trace metals from kitchen faucets , 1984 .

[6]  Ronald D. Hilburn,et al.  Modeling copper corrosion in water with low conductivity by using electrochemical techniques , 1983 .

[7]  D. Ives,et al.  Copper Corrosion I . Thermodynamic Aspects , 1962 .

[8]  Gary S. Logsdon,et al.  Principles of internal corrosion and corrosion monitoring , 1983 .

[9]  C. S. Wong,et al.  Contamination of tap water by lead pipe and solder , 1976, Bulletin of environmental contamination and toxicology.

[10]  J. E. Singley,et al.  The search for a corrosion index , 1981 .

[11]  John F. Ferguson,et al.  The pitting corrosion of copper , 1994 .

[12]  J. E. Singley,et al.  Electrochemical nature of lead contamination , 1994 .

[13]  E. Calabrese,et al.  Lead Dissolution From Soldered Joints , 1985 .

[14]  Bill Freedman,et al.  Metal Mobilization in Home Well Water Systems in Nova Scotia , 1985 .

[15]  T. Lyon,et al.  Corrosion in Solder Jointed Copper Tubes Resulting in Lead Contamination of Drinking Water , 1977 .

[16]  J. E. Singley,et al.  Influence of Buffer Capacity, Chlorine Residual, and Flow Rate on Corrosion of Mild Steel and Copper , 1987 .

[17]  S. Pocock,et al.  CONTRIBUTION OF LEAD IN DRINKING WATER TO BLOOD-LEAD , 1977, The Lancet.

[18]  J. Coombs,et al.  The corrosion of copper by chlorinated drinking waters , 1982 .

[19]  Floyd B. Taylor,et al.  Control of lead, copper, and iron pipe corrosion in Boston , 1983 .