The Z-source breaker for ship power system protection

The Navy is considering alternative power system architectures to traditional 60 Hz Medium Voltage Alternating Current (MVAC) power systems for shipboard operation. One alternative architecture being strongly considered for several reasons, is Medium-Voltage Direct Current (MVDC). With that consideration, comes the need for effective electrical fault risk prevention and mitigation. This paper explores the application of the recently invented “z-source dc circuit breaker” to a ship power system. Specifically, detailed simulation is used to study the response of the z-source breaker to faults at various locations in a ring-type dc power system. The addition of a central control unit results in ideal response in that only breakers necessary to isolate the fault remain open for all cases. This paper further explores implementation issues for eventual application to Navy ships.

[1]  Keith A. Corzine,et al.  Modified Z-Source DC Circuit Breaker Topologies , 2016, IEEE Transactions on Power Electronics.

[2]  Keith Corzine,et al.  A new z-source dc circuit breaker , 2010, ISIE 2010.

[3]  R. Cuzner,et al.  DC zonal electrical system fault isolation and reconfiguration , 2009, 2009 IEEE Electric Ship Technologies Symposium.

[4]  I Kondratiev,et al.  Invariant based ship DC power system design , 2011, 2011 IEEE Electric Ship Technologies Symposium.

[5]  Kevin McCoy,et al.  Next Generation Integrated Power System: NGIPS Technology Development Roadmap , 2007 .

[6]  Lynn J. Petersen,et al.  Navy efforts towards development of future naval weapons and integration into an All Electric Warship ( AEW ) , 2011 .

[7]  Keith Corzine,et al.  The Z-source breaker for fault protection in ship power systems , 2014, 2014 International Symposium on Power Electronics, Electrical Drives, Automation and Motion.

[8]  J. L. Kirtley,et al.  Design of DC system protection , 2013, 2013 IEEE Electric Ship Technologies Symposium (ESTS).

[9]  Edwin Zivi Design of robust shipboard power automation systems , 2005, Annu. Rev. Control..

[10]  M. Sumner,et al.  Fault Location in a Zonal DC Marine Power System Using Active Impedance Estimation , 2010, IEEE Transactions on Industry Applications.

[11]  John S. Morton Circuit Breaker and Protection Requirements for DC Switchgear used in Rapid Transit Systems , 1985, IEEE Transactions on Industry Applications.

[12]  R. Cuzner,et al.  Circuit breaker protection considerations in power converter-fed DC Systems , 2009, 2009 IEEE Electric Ship Technologies Symposium.

[13]  G. D. Gregory Applying low-voltage circuit breakers in direct current systems , 1994 .

[14]  P. Prempraneerach,et al.  Optimization of a z-source DC circuit breaker , 2013, 2013 IEEE Electric Ship Technologies Symposium (ESTS).

[15]  Robert M. Cuzner,et al.  The Status of DC Micro-Grid Protection , 2008, 2008 IEEE Industry Applications Society Annual Meeting.