"Patient-specific validation of deformable image registration in radiation therapy: Overview and caveats".

Over the last few decades, deformable image registration (DIR) has gained popularity in image-guided radiation therapy for a number of applications, such as contour propagation, dose warping, and accumulation. Although this raises promising perspectives for the improvement of treatment outcomes and quality of radiotherapy clinical practice, the variety of proposed DIR algorithms, combined with the lack of an effective quantitative quality control metric of the registration, is slowing the transfer of DIR into the clinical routine. Recently, a task group (AAPM TG132) report was published outlining the essential aspects of DIR for image guidance in radiotherapy. However, an accurate and efficient patient-specific validation is not yet defined, and appropriate metrics should be identified to achieve the definition of both geometric and dosimetric accuracy. In this respect, the use of a dense set of anatomical landmarks, along with additional evaluations on contours or deformation field analysis, are likely to drive patient-specific DIR validation in clinical image-guided radiotherapy applications to account for geometric inaccuracies. Automatic and efficient strategies able to provide spatial information of DIR uncertainties and to evaluate monomodal and multimodal image registration, as well as to describe homogenous and un-contrasted regions are believed to represent the future direction in DIR validation. But especially in the case of DIR applications for dose mapping and accumulation, the need of accurate patient-specific validation is not only limited to the evaluation of geometric accuracy. In fact, the need to account for dosimetric inaccuracies due to DIR represents another important area in the field of adaptive treatments. Different approaches are currently being investigated to quantify the effect of DIR error on dose analysis, mainly relying on clinically relevant dose metrics, or on the study of deformation field properties for a voxel-by-voxel evaluation. However, novel research is required for the definition of dedicated and personalized measures capable to relate the geometric and dosimetric inaccuracies, thus bearing useful information for a safe use of DIR by clinical end users. In this paper we provide insights on DIR results evaluation on a patient-specific basis, facing the issues of both geometric and dosimetric paradigms. Challenges on DIR validation are overviewed and discussed, in order to push preliminary clinical guidelines forward on this fundamental topic and boost the implementation of more robust and reliable patient-specific evaluation metrics.

[1]  Marco Riboldi,et al.  Magnetic resonance imaging-guided versus surrogate-based motion tracking in liver radiation therapy: a prospective comparative study. , 2015, International journal of radiation oncology, biology, physics.

[2]  Daniel A Low,et al.  A neural network approach for fast, automated quantification of DIR performance , 2017, Medical physics.

[3]  Chih-Cheng Hung,et al.  Contour propagation using non-uniform cubic B-splines for lung tumor delineation in 4D-CT , 2016, International Journal of Computer Assisted Radiology and Surgery.

[4]  E W Korevaar,et al.  An automated, quantitative, and case-specific evaluation of deformable image registration in computed tomography images , 2018, Physics in medicine and biology.

[5]  Max A. Viergever,et al.  DIRBoost-An algorithm for boosting deformable image registration: Application to lung CT intra-subject registration , 2014, Medical Image Anal..

[6]  Hualiang Zhong,et al.  FEM-based evaluation of deformable image registration for radiation therapy , 2007, Physics in medicine and biology.

[7]  Ping Xia,et al.  Can positron emission tomography (PET) or PET/Computed Tomography (CT) acquired in a nontreatment position be accurately registered to a head-and-neck radiotherapy planning CT? , 2009, International Journal of Radiation Oncology, Biology, Physics.

[8]  Sébastien Ourselin,et al.  Toward adaptive radiotherapy for head and neck patients: Uncertainties in dose warping due to the choice of deformable registration algorithm. , 2015, Medical physics.

[9]  William M. Wells,et al.  Estimation of Delivered Dose in Radiotherapy: The Influence of Registration Uncertainty , 2011, MICCAI.

[10]  Hojin Kim,et al.  Validating Dose Uncertainty Estimates Produced by AUTODIRECT: An Automated Program to Evaluate Deformable Image Registration Accuracy , 2017, Technology in cancer research & treatment.

[11]  Sasa Mutic,et al.  SIFT-based dense pixel tracking on 0.35 T cine-MR images acquired during image-guided radiation therapy with application to gating optimization. , 2015, Medical physics.

[12]  C P Karger,et al.  Estimation of the uncertainty of elastic image registration with the demons algorithm. , 2013, Physics in medicine and biology.

[13]  Joseph O Deasy,et al.  Deformable registration of abdominal kilovoltage treatment planning CT and tomotherapy daily megavoltage CT for treatment adaptation. , 2009, Medical physics.

[14]  G C Sharp,et al.  Validation of a deformable image registration technique for cone beam CT-based dose verification. , 2014, Medical physics.

[15]  Patrick Clarysse,et al.  A Comparison Framework for Breathing Motion Estimation Methods From 4-D Imaging , 2007, IEEE Transactions on Medical Imaging.

[16]  O. Acosta,et al.  Quantification of dose uncertainties in cumulated dose estimation compared to planned dose in prostate IMRT. , 2016, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[17]  Hojin Kim,et al.  An automated deformable image registration evaluation of confidence tool , 2016, Physics in medicine and biology.

[18]  K. Brock Results of a multi-institution deformable registration accuracy study (MIDRAS). , 2010, International journal of radiation oncology, biology, physics.

[19]  Rosalind Perrin,et al.  Four-Dimensional Dose Reconstruction for Scanned Proton Therapy Using Liver 4DCT-MRI. , 2016, International journal of radiation oncology, biology, physics.

[20]  A N T J Kotte,et al.  First patients treated with a 1.5 T MRI-Linac: clinical proof of concept of a high-precision, high-field MRI guided radiotherapy treatment , 2017, Physics in medicine and biology.

[21]  Indrin J Chetty,et al.  Deformable image registration based automatic CT-to-CT contour propagation for head and neck adaptive radiotherapy in the routine clinical setting. , 2014, Medical physics.

[22]  Jeffrey V Siebers,et al.  A distance to dose difference tool for estimating the required spatial accuracy of a displacement vector field. , 2010, Medical physics.

[23]  Andrés Santos,et al.  Organ-focused mutual information for nonrigid multimodal registration of liver CT and Gd-EOB-DTPA-enhanced MRI , 2014, Medical Image Anal..

[24]  Marco Riboldi,et al.  Evaluation of residual abdominal tumour motion in carbon ion gated treatments through respiratory motion modelling. , 2017, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[25]  Vladimir Pekar,et al.  Full orientation invariance and improved feature selectivity of 3D SIFT with application to medical image analysis , 2008, 2008 IEEE Computer Society Conference on Computer Vision and Pattern Recognition Workshops.

[26]  Y G Roussakis,et al.  University of Birmingham Validation of a dose warping algorithm using clinically realistic scenarios , 2015 .

[27]  Michael B Sharpe,et al.  Image-guided radiotherapy: rationale, benefits, and limitations. , 2006, The Lancet. Oncology.

[28]  B. Gino Fallone,et al.  Assessment of a commercially available automatic deformable registration system , 2010, Journal of applied clinical medical physics.

[29]  Karl Rohr,et al.  Development and validation of a multi-step approach to improved detection of 3D point landmarks in tomographic images , 2005, Image Vis. Comput..

[30]  K. Brock,et al.  Accurate accumulation of dose for improved understanding of radiation effects in normal tissue. , 2010, International Journal of Radiation Oncology, Biology, Physics.

[31]  Jinkoo Kim,et al.  Contouring variability of human- and deformable-generated contours in radiotherapy for prostate cancer , 2015, Physics in medicine and biology.

[32]  Jeffrey V Siebers,et al.  Estimation of three-dimensional intrinsic dosimetric uncertainties resulting from using deformable image registration for dose mapping. , 2011, Medical physics.

[33]  David Tilly,et al.  Dose mapping sensitivity to deformable registration uncertainties in fractionated radiotherapy – applied to prostate proton treatments , 2013, BMC medical physics.

[34]  G S Mageras,et al.  Evaluation of deformable image registration and a motion model in CT images with limited features , 2012, Physics in medicine and biology.

[35]  Wei Liu,et al.  Consensus Guidelines for Implementing Pencil-Beam Scanning Proton Therapy for Thoracic Malignancies on Behalf of the PTCOG Thoracic and Lymphoma Subcommittee. , 2017, International journal of radiation oncology, biology, physics.

[36]  Parminder S Basran,et al.  Deformable versus rigid registration of PET/CT images for radiation treatment planning of head and neck and lung cancer patients: a retrospective dosimetric comparison , 2014, Radiation Oncology.

[37]  Wolfgang Birkfellner,et al.  Visualization of Deformable Image Registration Quality Using Local Image Dissimilarity , 2016, IEEE Trans. Medical Imaging.

[38]  Jan Seuntjens,et al.  A direct voxel tracking method for four-dimensional Monte Carlo dose calculations in deforming anatomy. , 2006, Medical physics.

[39]  Maria Francesca Spadea,et al.  Automatic segmentation and online virtualCT in head-and-neck adaptive radiation therapy. , 2012, International journal of radiation oncology, biology, physics.

[40]  Rob H N Tijssen,et al.  Magnetic resonance imaging in precision radiation therapy for lung cancer. , 2017, Translational lung cancer research.

[41]  Adil Al-Mayah,et al.  Radiation dose response simulation for biomechanical-based deformable image registration of head and neck cancer treatment , 2015, Physics in medicine and biology.

[42]  A. Ahmadian,et al.  Evaluation of whole‐body MR to CT deformable image registration , 2013, Journal of applied clinical medical physics.

[43]  Jinkoo Kim,et al.  A novel approach for establishing benchmark CBCT/CT deformable image registrations in prostate cancer radiotherapy. , 2013, Physics in medicine and biology.

[44]  Matthias Guckenberger,et al.  A multi-institution evaluation of deformable image registration algorithms for automatic organ delineation in adaptive head and neck radiotherapy , 2012, Radiation oncology.

[45]  W. Tomé,et al.  On the dosimetric effect and reduction of inverse consistency and transitivity errors in deformable image registration for dose accumulation. , 2011, Medical physics.

[46]  Paul Aljabar,et al.  Clinical evaluation of atlas and deep learning based automatic contouring for lung cancer. , 2017, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[47]  L. Xing,et al.  Feature-based rectal contour propagation from planning CT to cone beam CT. , 2008, Medical physics.

[48]  Ya Wang,et al.  The distance discordance metric---a novel approach to quantifying spatial uncertainties in intra-and inter-patient deformable image registration , 2016 .

[49]  Geoffrey D. Hugo,et al.  Advances in 4D radiation therapy for managing respiration: part II - 4D treatment planning. , 2012, Zeitschrift fur medizinische Physik.

[50]  Max A. Viergever,et al.  A survey of medical image registration , 1998, Medical Image Anal..

[51]  Ross Berbeco,et al.  Sensitivity study of voxel-based PET image comparison to image registration algorithms. , 2014, Medical physics.

[52]  Richard Speight,et al.  Automated, reference-free local error assessment of multimodal deformable image registration for radiotherapy in the head and neck. , 2017, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[53]  Ghassan Hamarneh,et al.  n -SIFT: n -Dimensional Scale Invariant Feature Transform , 2009, IEEE Trans. Image Process..

[54]  Brian B. Avants,et al.  Evaluation of Registration Methods on Thoracic CT: The EMPIRE10 Challenge , 2011, IEEE Transactions on Medical Imaging.

[55]  Stefano Moriconi,et al.  A Comparative Evaluation of 3 Different Free-Form Deformable Image Registration and Contour Propagation Methods for Head and Neck MRI: The Case of Parotid Changes During Radiotherapy , 2017, Technology in cancer research & treatment.

[56]  N. Schwenzer,et al.  A strategy for multimodal deformable image registration to integrate PET/MR into radiotherapy treatment planning , 2013, Acta oncologica.

[57]  G Baroni,et al.  Validation of Automatic Contour Propagation for 4D Treatment Planning Using Multiple Metrics , 2013, Technology in cancer research & treatment.

[58]  Taweap Sanghangthum,et al.  Accuracy of eight deformable image registration (DIR) methods for tomotherapy megavoltage computed tomography (MVCT) images , 2017, Journal of medical radiation sciences.

[59]  Samuel G Armato,et al.  Effect of deformable registration on the dose calculated in radiation therapy planning CT scans of lung cancer patients. , 2014, Medical physics.

[60]  W Birkfellner,et al.  Automatic quantification of multi-modal rigid registration accuracy using feature detectors. , 2016, Physics in medicine and biology.

[61]  Gregory Sharp,et al.  Analytic regularization for landmark-based image registration , 2012, Physics in medicine and biology.

[62]  R Calandrino,et al.  Validation of a method for "dose of the day" calculation in head-neck tomotherapy by using planning ct-to-MVCT deformable image registration. , 2017, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[63]  R. Castillo,et al.  A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets , 2009, Physics in medicine and biology.

[64]  Amit Sawant,et al.  Dose warping performance in deformable image registration in lung. , 2017, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[65]  Jason Vickress,et al.  Representing the dosimetric impact of deformable image registration errors , 2017, Physics in medicine and biology.

[66]  Davide Fontanarosa,et al.  Review of ultrasound image guidance in external beam radiotherapy part II: intra-fraction motion management and novel applications , 2016, Physics in medicine and biology.

[67]  Katia Parodi,et al.  Vision 20/20: Positron emission tomography in radiation therapy planning, delivery, and monitoring. , 2015, Medical physics.

[68]  Tobias Knopp,et al.  Influence of deformable image registration on 4D dose simulation for extracranial SBRT: A multi-registration framework study. , 2018, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[69]  J. Dempsey,et al.  Evaluation of the gamma dose distribution comparison method. , 2003, Medical physics.

[70]  Lone Hoffmann,et al.  Anatomical landmarks accurately determine interfractional lymph node shifts during radiotherapy of lung cancer patients. , 2015, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[71]  Michael Velec,et al.  Effect of deformable registration uncertainty on lung SBRT dose accumulation. , 2015, Medical physics.

[72]  Damien Charles Weber,et al.  An evaluation of rescanning technique for liver tumour treatments using a commercial PBS proton therapy system. , 2016, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[73]  Joao Seco,et al.  A comparison of dose warping methods for 4D Monte Carlo dose calculations in lung , 2008 .

[74]  Cai Grau,et al.  Open source deformable image registration system for treatment planning and recurrence CT scans , 2016, Strahlentherapie und Onkologie.

[75]  Alexander Fischer,et al.  Evaluation of elastix-based propagated align algorithm for VOI- and voxel-based analysis of longitudinal 18F-FDG PET/CT data from patients with non-small cell lung cancer (NSCLC) , 2015, EJNMMI Research.

[76]  Max A. Viergever,et al.  Semi-automatic construction of reference standards for evaluation of image registration , 2011, Medical Image Anal..

[77]  Marco Riboldi,et al.  Quantification of organ motion based on an adaptive image-based scale invariant feature method. , 2013, Medical physics.

[78]  Michael Brady,et al.  MIND: Modality independent neighbourhood descriptor for multi-modal deformable registration , 2012, Medical Image Anal..

[79]  David J. Hawkes,et al.  Respiratory motion models: a review. , 2013 .

[80]  E Weiss,et al.  A method to evaluate dose errors introduced by dose mapping processes for mass conserving deformations. , 2012, Medical physics.

[81]  Michael Velec,et al.  Effect of breathing motion on radiotherapy dose accumulation in the abdomen using deformable registration. , 2011, International journal of radiation oncology, biology, physics.

[82]  L Dong,et al.  Quantification of accuracy of the automated nonlinear image matching and anatomical labeling (ANIMAL) nonlinear registration algorithm for 4D CT images of lung. , 2007, Medical physics.

[83]  Andrzej Niemierko,et al.  A free program for calculating EUD-based NTCP and TCP in external beam radiotherapy. , 2007, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[84]  Nicholas Hardcastle,et al.  Accuracy of deformable image registration for contour propagation in adaptive lung radiotherapy , 2013, Radiation oncology.

[85]  Y X Yang,et al.  A hybrid approach for fusing 4D-MRI temporal information with 3D-CT for the study of lung and lung tumor motion. , 2015, Medical physics.

[86]  Yaoqin Xie,et al.  Deformable image registration of liver with consideration of lung sliding motion. , 2011, Medical physics.

[87]  Xiao Han,et al.  Technical Note: The impact of deformable image registration methods on dose warping , 2018, Medical physics.

[88]  Gregory C Sharp,et al.  Scale invariant feature transform in adaptive radiation therapy: a tool for deformable image registration assessment and re-planning indication , 2013, Physics in medicine and biology.

[89]  David R. Haynor,et al.  PET-CT image registration in the chest using free-form deformations , 2003, IEEE Transactions on Medical Imaging.

[90]  Jan-Jakob Sonke,et al.  Deformable image registration for adaptive radiation therapy of head and neck cancer: accuracy and precision in the presence of tumor changes. , 2014, International journal of radiation oncology, biology, physics.

[91]  G. Sharp,et al.  Vision 20/20: perspectives on automated image segmentation for radiotherapy. , 2014, Medical physics.

[92]  Hualiang Zhong,et al.  An energy transfer method for 4D Monte Carlo dose calculation. , 2008, Medical physics.

[93]  Benoît Macq,et al.  Comparison of 12 deformable registration strategies in adaptive radiation therapy for the treatment of head and neck tumors. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[94]  J Pukala,et al.  A GPU based high-resolution multilevel biomechanical head and neck model for validating deformable image registration. , 2014, Medical physics.

[95]  Nikos Paragios,et al.  Deformable Medical Image Registration: A Survey , 2013, IEEE Transactions on Medical Imaging.

[96]  R Mohan,et al.  Quantifying the accuracy of automated structure segmentation in 4D CT images using a deformable image registration algorithm. , 2008, Medical physics.

[97]  Paul Keall,et al.  Evaluation of 4-dimensional computed tomography to 4-dimensional cone-beam computed tomography deformable image registration for lung cancer adaptive radiation therapy. , 2013, International journal of radiation oncology, biology, physics.

[98]  Mechthild Krause,et al.  Radiation oncology in the era of precision medicine , 2016, Nature Reviews Cancer.

[99]  Wolfgang A. Tomé,et al.  The effect on dose accumulation accuracy of inverse-consistency and transitivity error reduced deformation maps , 2014, Australasian Physical & Engineering Sciences in Medicine.

[100]  Pascal Haigron,et al.  Evaluation of Deformable Image Registration Methods for Dose Monitoring in Head and Neck Radiotherapy , 2015, BioMed research international.

[101]  K. Brock,et al.  Use of image registration and fusion algorithms and techniques in radiotherapy: Report of the AAPM Radiation Therapy Committee Task Group No. 132 , 2017, Medical physics.

[102]  M van Herk,et al.  Validation of deformable registration in head and neck cancer using analysis of variance. , 2012, Medical physics.

[103]  Christian P Karger,et al.  A stochastic approach to estimate the uncertainty of dose mapping caused by uncertainties in b-spline registration. , 2012, Medical physics.

[104]  M A Deeley,et al.  Comparison of manual and automatic segmentation methods for brain structures in the presence of space-occupying lesions: a multi-expert study , 2011, Physics in medicine and biology.

[105]  Kanako Kimura,et al.  Effect of DIR uncertainty on prostate passive-scattering proton therapy dose accumulation. , 2017, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[106]  A. Niemierko Reporting and analyzing dose distributions: a concept of equivalent uniform dose. , 1997, Medical physics.

[107]  D. Jaffray Image-guided radiotherapy: from current concept to future perspectives , 2012, Nature Reviews Clinical Oncology.

[108]  David Sarrut,et al.  Deformable registration for image-guided radiation therapy. , 2006, Zeitschrift fur medizinische Physik.

[109]  Rolf Bendl,et al.  Construction of a biomechanical head and neck motion model as a guide to evaluation of deformable image registration , 2017, Physics in medicine and biology.

[110]  Torsten Rohlfing,et al.  Image Similarity and Tissue Overlaps as Surrogates for Image Registration Accuracy: Widely Used but Unreliable , 2012, IEEE Transactions on Medical Imaging.

[111]  R. Castillo,et al.  Four-dimensional deformable image registration using trajectory modeling , 2010, Physics in medicine and biology.

[112]  Icru Prescribing, recording, and reporting photon beam therapy , 1993 .

[113]  Louis Potters,et al.  Deformable image registration and interobserver variation in contour propagation for radiation therapy planning , 2016, Journal of applied clinical medical physics.

[114]  Max A. Viergever,et al.  A survey of medical image registration - under review , 2016, Medical Image Anal..

[115]  Hualiang Zhong,et al.  Monte Carlo dose mapping on deforming anatomy , 2009, Physics in medicine and biology.

[116]  Carlo Cavedon,et al.  Optimized PET Imaging for 4D Treatment Planning in Radiotherapy: the Virtual 4D PET Strategy , 2015, Technology in cancer research & treatment.

[117]  Marc L. Kessler,et al.  A Stochastic Approach to Estimate the UncertaintyInvolved in B-Spline Image Registration , 2009, IEEE Transactions on Medical Imaging.

[118]  David A Jaffray,et al.  Validation of biomechanical deformable image registration in the abdomen, thorax, and pelvis in a commercial radiotherapy treatment planning system , 2017, Medical physics.

[119]  Indrin J Chetty,et al.  An adaptive MR-CT registration method for MRI-guided prostate cancer radiotherapy , 2015, Physics in medicine and biology.

[120]  Gregory C Sharp,et al.  Evaluation of deformable registration of patient lung 4DCT with subanatomical region segmentations. , 2008, Medical physics.

[121]  Wolfgang A Tomé,et al.  The utilization of consistency metrics for error analysis in deformable image registration , 2009, Physics in medicine and biology.

[122]  Liyong Lin,et al.  First Clinical Investigation of Cone Beam Computed Tomography and Deformable Registration for Adaptive Proton Therapy for Lung Cancer. , 2016, International journal of radiation oncology, biology, physics.

[123]  Ye Duan,et al.  A method to detect landmark pairs accurately between intra‐patient volumetric medical images , 2017, Medical physics.

[124]  Sébastien Ourselin,et al.  Toward adaptive radiotherapy for head and neck patients: Feasibility study on using CT-to-CBCT deformable registration for "dose of the day" calculations. , 2014, Medical physics.

[125]  Taiki Magome,et al.  Characterization of deformation and physical force in uniform low contrast anatomy and its impact on accuracy of deformable image registration. , 2015, Medical physics.

[126]  Antje Knopf,et al.  Mapping motion from 4D-MRI to 3D-CT for use in 4D dose calculations: A technical feasibility study. , 2013, Medical physics.

[127]  Harini Veeraraghavan,et al.  A multiple-image-based method to evaluate the performance of deformable image registration in the pelvis , 2016, Physics in medicine and biology.

[128]  C J Moore,et al.  Automated delineation of radiotherapy volumes: are we going in the right direction? , 2013, The British journal of radiology.

[129]  Katia Parodi,et al.  Investigating CT to CBCT image registration for head and neck proton therapy as a tool for daily dose recalculation. , 2015, Medical physics.

[130]  Jeffrey V Siebers,et al.  A method to estimate the effect of deformable image registration uncertainties on daily dose mapping. , 2012, Medical physics.

[131]  David G. Lowe,et al.  Distinctive Image Features from Scale-Invariant Keypoints , 2004, International Journal of Computer Vision.

[132]  Tomas Kron,et al.  Accuracy and Utility of Deformable Image Registration in (68)Ga 4D PET/CT Assessment of Pulmonary Perfusion Changes During and After Lung Radiation Therapy. , 2015, International journal of radiation oncology, biology, physics.

[133]  Antje Knopf,et al.  Assessment of dosimetric errors induced by deformable image registration methods in 4D pencil beam scanned proton treatment planning for liver tumours. , 2018, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[134]  Gary J. Royle,et al.  A comprehensive evaluation of the accuracy of CBCT and deformable registration based dose calculation in lung proton therapy , 2017 .

[135]  Maria A Schmidt,et al.  Radiotherapy planning using MRI , 2015, Physics in medicine and biology.

[136]  Rafael García-Mollá,et al.  Validation of a deformable image registration produced by a commercial treatment planning system in head and neck. , 2015, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[137]  Eduard Schreibmann,et al.  A measure to evaluate deformable registration fields in clinical settings , 2012, Journal of applied clinical medical physics.

[138]  Josien P. W. Pluim,et al.  Supervised quality assessment of medical image registration: Application to intra-patient CT lung registration , 2012, Medical Image Anal..

[139]  K. Brock,et al.  Biomechanical deformable image registration of longitudinal lung CT images using vessel information , 2016, Physics in medicine and biology.

[140]  Nataliya Kovalchuk,et al.  Deformable registration of preoperative PET/CT with postoperative radiation therapy planning CT in head and neck cancer. , 2012, Radiographics : a review publication of the Radiological Society of North America, Inc.

[141]  Siyong Kim,et al.  Deformable image registration in radiation therapy , 2017, Radiation oncology journal.