Electronic plants

Integrated organic electronic analog and digital circuits can be formed within plant parts and live plants. The roots, stems, leaves, and vascular circuitry of higher plants are responsible for conveying the chemical signals that regulate growth and functions. From a certain perspective, these features are analogous to the contacts, interconnections, devices, and wires of discrete and integrated electronic circuits. Although many attempts have been made to augment plant function with electroactive materials, plants’ “circuitry” has never been directly merged with electronics. We report analog and digital organic electronic circuits and devices manufactured in living plants. The four key components of a circuit have been achieved using the xylem, leaves, veins, and signals of the plant as the template and integral part of the circuit elements and functions. With integrated and distributed electronics in plants, one can envisage a range of applications including precision recording and regulation of physiology, energy harvesting from photosynthesis, and alternatives to genetic modification for plant optimization.

[1]  M. Berggren,et al.  1 Supporting Information for : Electronic Control of Cell Detachment Using a Self-Doped Conducting Polymer , 2011 .

[2]  B. Sattelmacher,et al.  Is the infiltration-centrifugation technique appropriate for the isolation of apoplastic fluid? A critical evaluation with different plant species. , 2001, Physiologia plantarum.

[3]  O. Inganäs,et al.  Networks of electron-conducting polymer in matrices of ion-conducting polymers. Applications to fast electrodes , 1999 .

[4]  David Nilsson,et al.  Therapy using implanted organic bioelectronics , 2015, Science Advances.

[5]  Elisabeth Smela,et al.  Visualizing Ion Currents in Conjugated Polymers , 2004 .

[6]  L. Bernstein Method for determining solutes in the cell walls of leaves. , 1971, Plant physiology.

[7]  Curtis Shannon,et al.  Display of solid-state materials using bipolar electrochemistry. , 2010, Langmuir : the ACS journal of surfaces and colloids.

[8]  Christophe Bernard,et al.  High-performance transistors for bioelectronics through tuning of channel thickness , 2015, Science Advances.

[9]  Abraham Nudelman,et al.  NMR Chemical Shifts of Common Laboratory Solvents as Trace Impurities. , 1997, The Journal of organic chemistry.

[10]  Göran Gustafsson,et al.  Reconfigurable sticker label electronics manufactured from nanofibrillated cellulose-based self-adhesive organic electronic materials , 2013 .

[11]  J. Léger Organic Electronics: The Ions Have It , 2008 .

[12]  R. Leblanc,et al.  Interaction of the CdSe quantum dots with plant cell walls. , 2012, Colloids and surfaces. B, Biointerfaces.

[13]  G. Bolwell Biochemistry & Molecular Biology of Plants , 2001 .

[14]  J. Reynolds,et al.  Poly(3,4‐ethylenedioxythiophene) and Its Derivatives: Past, Present, and Future , 2000 .

[15]  John R. Reynolds,et al.  Conjugated Polymers : Theory, Synthesis, Properties, and Characterization , 2006 .

[16]  R. Gabrielsson,et al.  Electronic polymers and DNA self-assembled in nanowire transistors. , 2013, Small.

[17]  Zhifeng Yi,et al.  Mesoporous silica nanoparticles as a biomolecule delivery vehicle in plants , 2013, Journal of Nanoparticle Research.

[18]  O. Inganäs,et al.  Iron-Catalyzed Polymerization of Alkoxysulfonate-Functionalized 3,4-Ethylenedioxythiophene Gives Water-Soluble Poly(3,4-ethylenedioxythiophene) of High Conductivity , 2009 .

[19]  M. Berggren,et al.  Visualizing the Electric Field in Electrolytes Using Electrochromism from a Conjugated Polymer , 2005 .

[20]  Maria Forsyth,et al.  High Rates of Oxygen Reduction over a Vapor Phase–Polymerized PEDOT Electrode , 2008, Science.

[21]  D. Miller,et al.  Studies of Root Function in Zea mays: III. Xylem Sap Composition at Maximum Root Pressure Provides Evidence of Active Transport into the Xylem and a Measurement of the Reflection Coefficient of the Root. , 1985, Plant physiology.

[22]  David C. Martin,et al.  In vivo polymerization of poly(3,4-ethylenedioxythiophene) in the living rat hippocampus does not cause a significant loss of performance in a delayed alternation task , 2014, Journal of neural engineering.

[23]  Robert Forchheimer,et al.  Electrochemical Logic Circuits , 2005, New Electronics.

[24]  J. Bobacka,et al.  Potential Stability of All-Solid-State Ion-Selective Electrodes Using Conducting Polymers as Ion-to-Electron Transducers. , 1999, Analytical chemistry.

[25]  Ardemis A. Boghossian,et al.  Plant nanobionics approach to augment photosynthesis and biochemical sensing. , 2014, Nature materials.

[26]  G. Preston,et al.  The Infiltration-centrifugation Technique for Extraction of Apoplastic Fluid from Plant Leaves Using Phaseolus vulgaris as an Example , 2014, Journal of visualized experiments : JoVE.

[27]  David Nilsson,et al.  Bi-stable and dynamic current modulation in electrochemical organic transistors , 2002 .

[28]  Peter Andersson,et al.  Active Matrix Displays Based on All‐Organic Electrochemical Smart Pixels Printed on Paper , 2002 .

[29]  Robert A. Martienssen,et al.  The Biology of Plants , 2012 .

[30]  Manfred Lindau,et al.  Direct Measurement of Ion Mobility in a Conducting Polymer , 2013, Advanced materials.

[31]  M. Rai,et al.  In vitro antifungal efficacy of copper nanoparticles against selected crop pathogenic fungi , 2014 .