Measurement of interface pressure applied by medical compression bandages

Medical compression bandages (MCBs) are widely used to treat venous leg ulcers. Interface pressure measurement devices like PicoPress® transducer are used occasionally to measure the pressure applied by MCBs to train nurses to apply MCBs with the correct pressure profile to patient's leg and for quality assurance purposes. However, most of these devices provide only single point pressure measurement. Some of them like the Medical Stocking Tester (MST) and the Oxford Pressure Monitoring MK can provide multiple points of pressure measurement simultaneously. However, the current available systems cannot map the pressures applied by MCBs to a leg at 16 or more points simultaneously. Flexible sensors like FlexiForce® seem to provide a good alternative to current pressure measurement system. This paper will report on the work carried out to compare the pressure measured using FlexiForce® force sensors with the pressures measured using PicoPress®, which is a pneumatic transducer, and FS01 force sensor, which is an ultra profile rigid MEMS force sensor. In addition, it will compare the pressures measured using the three sensing transducers with the pressures computed from the amount of extension in the MCB, which is applied to the medium which these sensors are attached to.

[1]  E. A. Nelson,et al.  Compression for venous leg ulcers. , 2001, The Cochrane database of systematic reviews.

[2]  D. Tolson,et al.  Class-3c compression bandaging for venous ulcers: comparison of spiral and figure-of-eight techniques. , 2006, Journal of advanced nursing.

[3]  A. Satpathy,et al.  Is compression bandaging accurate? The routine use of interface pressure measurements in compression bandaging of venous leg ulcers , 2006 .

[4]  P. Allan,et al.  Chronic venous insufficiency: clinical and duplex correlations. The Edinburgh Vein Study of venous disorders in the general population. , 2002, Journal of vascular surgery.

[5]  Theodore E Milner,et al.  A technique for conditioning and calibrating force-sensing resistors for repeatable and reliable measurement of compressive force. , 2008, Journal of biomechanics.

[6]  H. Schumann,et al.  Bandage pressure measurement and training: simple interventions to improve efficacy in compression bandaging , 2009, International wound journal.

[7]  M. Ferguson-Pell,et al.  Evaluation of a sensor for low interface pressure applications. , 2000, Medical engineering & physics.

[9]  H. Ishibashi,et al.  A comparison of interface pressure and stiffness between elastic stockings and bandages , 2009, Phlebology.

[10]  Rong Liu,et al.  Objective Evaluation of Skin Pressure Distribution of Graduated Elastic Compression Stockings , 2005, Dermatologic surgery : official publication for American Society for Dermatologic Surgery [et al.].

[11]  Bernard Bayle,et al.  Nonlinear modeling of low cost force sensors , 2008, 2008 IEEE International Conference on Robotics and Automation.

[12]  Xin Zhang,et al.  Skin pressure profiles and variations with body postural changes beneath medical elastic compression stockings , 2007, International journal of dermatology.

[13]  L. Vinckx,et al.  Analysis of the pressure perturbation due to the introduction of a measuring probe under an elastic garment , 2006, Medical and Biological Engineering and Computing.

[14]  Elizabeth Andrea Nelson A study of patient and nurse factors influencing sub-bandage pressure , 2001 .

[15]  M. Clark,et al.  Measurement of Lower Leg Compression In Vivo: Recommendations for the Performance of Measurements of Interface Pressure and Stiffness , 2006, Dermatologic surgery : official publication for American Society for Dermatologic Surgery [et al.].

[16]  J. Beebe-Dimmer,et al.  The epidemiology of chronic venous insufficiency and varicose veins. , 2005, Annals of epidemiology.

[17]  Al Khaburi,et al.  Pressure mapping of medical compression bandages used for venous leg ulcer treatment , 2010 .

[18]  Steve Thomas,et al.  Laboratory-based evaluation of a compression-bandaging system. , 2003, Nursing times.

[19]  C. Moffatt Variability of pressure provided by sustained compression , 2008, International wound journal.

[20]  V Allen,et al.  Accuracy of interface pressure measurement systems. , 1993, Journal of biomedical engineering.

[21]  M W Ferguson-Pell,et al.  Design Criteria for the Measurement of Pressure at Body/Support Interfaces: , 1980 .

[22]  I Gaied,et al.  Experimental assessment and analytical 2D predictions of the stocking pressures induced on a model leg by Medical Compressive Stockings. , 2006, Journal of biomechanics.

[23]  N. Cullum,et al.  Four layer bandage compared with short stretch bandage for venous leg ulcers: systematic review and meta-analysis of randomised controlled trials with data from individual patients , 2009, BMJ : British Medical Journal.

[24]  H. Partsch,et al.  Influence of Different Materials in Multicomponent Bandages on Pressure and Stiffness of the Final Bandage , 2008, Dermatologic surgery : official publication for American Society for Dermatologic Surgery [et al.].

[25]  H Partsch,et al.  The use of pressure change on standing as a surrogate measure of the stiffness of a compression bandage. , 2005, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.