A magnetic resonance (MR) microscopy system using a microfluidically cryo-cooled planar coil.

We present the development of a microfluidically cryo-cooled planar coil for magnetic resonance (MR) microscopy. Cryogenically cooling radiofrequency (RF) coils for magnetic resonance imaging (MRI) can improve the signal to noise ratio (SNR) of the experiment. Conventional cryostats typically use a vacuum gap to keep samples to be imaged, especially biological samples, at or near room temperature during cryo-cooling. This limits how close a cryo-cooled coil can be placed to the sample. At the same time, a small coil-to-sample distance significantly improves the MR imaging capability due to the limited imaging depth of planar MR microcoils. These two conflicting requirements pose challenges to the use of cryo-cooling in MR microcoils. The use of a microfluidic based cryostat for localized cryo-cooling of MR microcoils is a step towards eliminating these constraints. The system presented here consists of planar receive-only coils with integrated cryo-cooling microfluidic channels underneath, and an imaging surface on top of the planar coils separated by a thin nitrogen gas gap. Polymer microfluidic channel structures fabricated through soft lithography processes were used to flow liquid nitrogen under the coils in order to cryo-cool the planar coils to liquid nitrogen temperature (-196 °C). Two unique features of the cryo-cooling system minimize the distance between the coil and the sample: (1) the small dimension of the polymer microfluidic channel enables localized cooling of the planar coils, while minimizing thermal effects on the nearby imaging surface. (2) The imaging surface is separated from the cryo-cooled planar coil by a thin gap through which nitrogen gas flows to thermally insulate the imaging surface, keeping it above 0 °C and preventing potential damage to biological samples. The localized cooling effect was validated by simulations, bench testing, and MR imaging experiments. Using this cryo-cooled planar coil system inside a 4.7 Tesla MR system resulted in an average image SNR enhancement of 1.47 ± 0.11 times relative to similar room-temperature coils.

[1]  J. B. Kneeland,et al.  Planar-pair local coils for high-resolution magnetic resonance imaging, particularly of the temporomandibular joint. , 1986, Medical physics.

[2]  Yoshinori Yokoyama,et al.  Thermal micro pumps for a loop-type micro channel , 2004 .

[3]  D. DeVoe,et al.  An electrohydrodynamic polarization micropump for electronic cooling , 2001 .

[4]  T. Kenny,et al.  Micromachined jets for liquid impingement cooling of VLSI chips , 2004, Journal of Microelectromechanical Systems.

[5]  Mark A. Griswold,et al.  SMASH imaging with an eight element multiplexed RF coil array , 2000 .

[6]  M. McDougall,et al.  64‐channel array coil for single echo acquisition magnetic resonance imaging , 2005, Magnetic resonance in medicine.

[7]  Felix W. Wehrli,et al.  In vivo MR micro imaging with conventional radiofrequency coils cooled to 77°K , 2000 .

[8]  Daniel Marek,et al.  Performance of a 200‐MHz cryogenic RF probe designed for MRI and MRS of the murine brain , 2008, Magnetic resonance in medicine.

[9]  Elad Harel,et al.  Magnetic resonance detection: spectroscopy and imaging of lab-on-a-chip. , 2009, Lab on a chip.

[10]  R.D. Black,et al.  Electronics for a high temperature superconducting receiver system for magnetic resonance microimaging , 1994, IEEE Transactions on Biomedical Engineering.

[11]  Rao Tummala,et al.  Fundamentals of Microsystems Packaging , 2001 .

[12]  R. Collin Foundations for microwave engineering , 1966 .

[13]  T. Niinikoski,et al.  Development of a miniature cryogenic fluid circuit and a cryogenic micropump , 2005 .

[14]  G. Whitesides,et al.  Patterning proteins and cells using soft lithography. , 1999, Biomaterials.

[15]  P Crozat,et al.  High‐temperature superconducting surface coil for in vivo microimaging of the human skin , 2001, Magnetic resonance in medicine.

[16]  L. C. Bourne,et al.  Thin film high temperature superconducting RF coils for low field MRI , 1994, Magnetic resonance in medicine.

[17]  Steven M. Wright,et al.  Single echo acquisition MRI using RF encoding , 2009, NMR in biomedicine.

[18]  J. Darabi,et al.  Development of an electrohydrodynamic injection micropump and its potential application in pumping fluids in cryogenic cooling systems , 2005, Journal of Microelectromechanical Systems.

[19]  R. Pease,et al.  High-performance heat sinking for VLSI , 1981, IEEE Electron Device Letters.