Low b-Value Diffusion-Weighted Cardiac Magnetic Resonance Imaging: Initial Results in Humans Using an Optimal Time-Window Imaging Approach

Objectives:Diffusion-weighted imaging (DWI) using low b-values permits imaging of intravoxel incoherent motion in tissues. However, low b-value DWI of the human heart has been considered too challenging because of additional signal loss due to physiological motion, which reduces both signal intensity and the signal-to-noise ratio (SNR). We address these signal loss concerns by analyzing cardiac motion during a heartbeat to determine the time-window during which cardiac bulk motion is minimal. Using this information to optimize the acquisition of DWI data and combining it with a dedicated image processing approach has enabled us to develop a novel low b-value diffusion-weighted cardiac magnetic resonance imaging approach, which significantly reduces intravoxel incoherent motion measurement bias introduced by motion. Materials and Methods:Simulations from displacement encoded motion data sets permitted the delineation of an optimal time-window with minimal cardiac motion. A number of single-shot repetitions of low b-value DWI cardiac magnetic resonance imaging data were acquired during this time-window under free-breathing conditions with bulk physiological motion corrected for by using nonrigid registration. Principal component analysis (PCA) was performed on the registered images to improve the SNR, and temporal maximum intensity projection (TMIP) was applied to recover signal intensity from time-fluctuant motion-induced signal loss. This PCATMIP method was validated with experimental data, and its benefits were evaluated in volunteers before being applied to patients. Results:Optimal time-window cardiac DWI in combination with PCATMIP postprocessing yielded significant benefits for signal recovery, contrast-to-noise ratio, and SNR in the presence of bulk motion for both numerical simulations and human volunteer studies. Analysis of mean apparent diffusion coefficient (ADC) maps showed homogeneous values among volunteers and good reproducibility between free-breathing and breath-hold acquisitions. The PCATMIP DWI approach also indicated its potential utility by detecting ADC variations in acute myocardial infarction patients. Conclusions:Studying cardiac motion may provide an appropriate strategy for minimizing the impact of bulk motion on cardiac DWI. Applying PCATMIP image processing improves low b-value DWI and enables reliable analysis of ADC in the myocardium. The use of a limited number of repetitions in a free-breathing mode also enables easier application in clinical conditions.

[1]  M. Cerqueira,et al.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. , 2002, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[2]  P Boesiger,et al.  Limitations of stimulated echo acquisition mode (steam) techniques in cardiac applications , 1995, Magnetic resonance in medicine.

[3]  Alexandre Vignaud,et al.  Diffusion-weighted echo planar imaging in patients with recent myocardial infarction , 2010, European Radiology.

[4]  A. Gjedde,et al.  Brain microvascular function during cardiopulmonary bypass. , 1987, The Journal of thoracic and cardiovascular surgery.

[5]  J T Kuikka,et al.  Combined diffusion and perfusion MRI with correlation to single-photon emission CT in acute ischemic stroke. Ischemic penumbra predicts infarct growth. , 1999, Stroke.

[6]  H. Wen,et al.  DENSE: displacement encoding with stimulated echoes in cardiac functional MRI. , 1999, Journal of magnetic resonance.

[7]  Robin M Heidemann,et al.  Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.

[8]  E. McVeigh,et al.  Signal-to-noise measurements in magnitude images from NMR phased arrays , 1997, Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136).

[9]  V. Wedeen,et al.  Diffusion Tensor Magnetic Resonance Imaging Mapping the Fiber Architecture Remodeling in Human Myocardium After Infarction: Correlation With Viability and Wall Motion , 2006, Circulation.

[10]  D. Le Bihan,et al.  Artifacts and pitfalls in diffusion MRI , 2006, Journal of magnetic resonance imaging : JMRI.

[11]  Timothy G Reese,et al.  Imaging myocardial fiber disarray and intramural strain hypokinesis in hypertrophic cardiomyopathy with MRI , 2006, Journal of magnetic resonance imaging : JMRI.

[12]  J. Tyberg,et al.  Edema as a very early marker for acute myocardial ischemia: a cardiovascular magnetic resonance study. , 2009, Journal of the American College of Cardiology.

[13]  Han Wen,et al.  In vivo study of microcirculation in canine myocardium using the IVIM method † , 2003, Magnetic resonance in medicine.

[14]  R R Edelman,et al.  Clinical experience with diffusion-weighted MR in patients with acute stroke. , 1998, AJNR. American journal of neuroradiology.

[15]  V. Wedeen,et al.  Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echo , 2003, Magnetic resonance in medicine.

[16]  Rachid Deriche,et al.  Regularizing Flows for Constrained Matrix-Valued Images , 2004, Journal of Mathematical Imaging and Vision.

[17]  Heng Tao Shen,et al.  Principal Component Analysis , 2009, Encyclopedia of Biometrics.

[18]  P. Grenier,et al.  MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders. , 1986, Radiology.

[19]  Peter Kellman,et al.  Fully automatic, retrospective enhancement of real‐time acquired cardiac cine MR images using image‐based navigators and respiratory motion‐corrected averaging , 2008, Magnetic resonance in medicine.

[20]  Timothy Edward John Behrens,et al.  Addressing a systematic vibration artifact in diffusion‐weighted MRI , 2009, Human brain mapping.

[21]  M. Cerqueira,et al.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association , 2002, The international journal of cardiovascular imaging.

[22]  Peter Boesiger,et al.  Diffusion imaging of the in vivo heart using spin echoes–considerations on bulk motion sensitivity , 2007, Magnetic resonance in medicine.

[23]  Gerald D Buckberg,et al.  Basic science review: the helix and the heart. , 2002, The Journal of thoracic and cardiovascular surgery.

[24]  G. Schlaug,et al.  The ischemic penumbra: operationally defined by diffusion and perfusion MRI. , 1999, Neurology.

[25]  P Croisille,et al.  PCATMIP: Enhancing signal intensity in diffusion‐weighted magnetic resonance imaging , 2011, Magnetic resonance in medicine.

[26]  F. Carreras,et al.  The sequence of regional ventricular motion. , 2006, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.