Fabrication of Biomedical Implants using Laser Engineered Net Shaping (LENS™)

There has been significant research, understanding of musculoskeletal disorders, but the development of suitable bone replacement materials for load-bearing applications is still lacking. Commercially available load-bearing implants/materials differ significantly from the natural host tissues in several aspects such as macro/microstructures, mechanical, physical and chemical properties. These differences limit the effectiveness of implants’ biological repair capability and longevity. One approach to enhance the cellular response and tissue integration of metal implants is to design and fabricate novel porous biomaterials that closely resemble the architecture and properties of natural bone tissue. In this article, we review application of Laser Engineered Net Shaping (LENS™) - an additive manufacturing process developed at Sandia National Laboratories, in developing materials/structures for load bearing implant application to enhance their in vivo life time. It has been established that LENS™ process is capable of fabricating near net shaped metallic implants with tailored porosity that can eliminate stress shielding issue associated with fully dense implants. Similarly, LENS™ is a potential technique to create compositionally and/or structurally graded implants. Further, functionally graded hard coatings have been developed via LENS™ to minimize the wear induced osteolysis. Finally, mono-block or unitized structures such as functionally graded CoCrMo or TiB-TiN coating on porous Ti6Al4V can also be fabricated using LENS™. In summary, the combination of novel designs and freeform fabrication capability of LENS process might have significant effect on development of novel implants/structures using varieties of metallic/ceramic biomaterials with tailored mechanical and biological properties.

[1]  R. Pilliar,et al.  A porous metal system for joint replacement surgery. , 1978, The International journal of artificial organs.

[2]  J. Jurvelin,et al.  Bone density at the proximal femur after total hip arthroplasty. , 1998, Clinical orthopaedics and related research.

[3]  Sie Chin Tjong,et al.  Microstructural and mechanical characteristics of in situ metal matrix composites , 2000 .

[4]  H Eufinger,et al.  Computer-assisted prefabrication of individual craniofacial implants. , 2001, AORN journal.

[5]  K. Chiu,et al.  Review Article: Polyethylene Wear and Osteolysis in Total Hip Arthroplasty , 2001, Journal of orthopaedic surgery.

[6]  Andrew G. Glen,et al.  APPL , 2001 .

[7]  S. Ramakrishna,et al.  Biomedical applications of polymer-composite materials: a review , 2001 .

[8]  Peter C. Collins,et al.  Direct laser deposition of in situ Ti–6Al–4V–TiB composites , 2003 .

[9]  A. Lombardi,et al.  Large versus small femoral heads in metal-on-metal total hip arthroplasty. , 2004, The Journal of arthroplasty.

[10]  J. Cuckler The Rationale for Metal-on-Metal Total Hip Arthroplasty , 2005, Clinical orthopaedics and related research.

[11]  Abhay Pandit,et al.  Fabrication methods of porous metals for use in orthopaedic applications. , 2006, Biomaterials.

[12]  Tadashi Kokubo,et al.  Pore throat size and connectivity determine bone and tissue ingrowth into porous implants: three-dimensional micro-CT based structural analyses of porous bioactive titanium implants. , 2006, Biomaterials.

[13]  A. Sargeant,et al.  Hip implants: Paper V. Physiological effects , 2006 .

[14]  Thomas P. Sculco,et al.  The Central Role of Wear Debris in Periprosthetic Osteolysis , 2006, HSS Journal.

[15]  H. Fraser,et al.  Laser-deposited Ti-Nb-Zr-Ta orthopedic alloys. , 2006, Journal of biomedical materials research. Part A.

[16]  B Vamsi Krishna,et al.  Low stiffness porous Ti structures for load-bearing implants. , 2007, Acta biomaterialia.

[17]  Clemens A van Blitterswijk,et al.  Bone ingrowth in porous titanium implants produced by 3D fiber deposition. , 2007, Biomaterials.

[18]  B Vamsi Krishna,et al.  Processing and biocompatibility evaluation of laser processed porous titanium. , 2007, Acta biomaterialia.

[19]  Amit Bandyopadhyay,et al.  Functionally graded Co-Cr-Mo coating on Ti-6Al-4V alloy structures. , 2008, Acta biomaterialia.

[20]  B. Stucker,et al.  A Feasibility Study of LENS® Deposition of CoCrMo Coating on a Titanium Substrate , 2008 .

[21]  Soumya Nag,et al.  Wear resistance of laser-deposited boride reinforced Ti-Nb–Zr–Ta alloy composites for orthopedic implants , 2008 .

[22]  B Vamsi Krishna,et al.  Fabrication of porous NiTi shape memory alloy structures using laser engineered net shaping. , 2009, Journal of biomedical materials research. Part B, Applied biomaterials.

[23]  Amit Bandyopadhyay,et al.  Application of Laser Engineered Net Shaping (LENS) to manufacture porous and functionally graded structures for load bearing implants , 2009, Journal of materials science. Materials in medicine.

[24]  A. Bandyopadhyay,et al.  Influence of porosity on mechanical properties and in vivo response of Ti6Al4V implants. , 2010, Acta biomaterialia.

[25]  Vamsi Krishna Balla,et al.  Laser processing of SiC-particle-reinforced coating on titanium , 2010 .

[26]  Sandip Bysakh,et al.  Microstructure, mechanical and wear properties of laser processed SiC particle reinforced coatings on titanium , 2011 .

[27]  A. Johnson,et al.  Survival of Hard-on-Hard Bearings in Total Hip Arthroplasty: A Systematic Review , 2011, Clinical orthopaedics and related research.

[28]  Vamsi Krishna Balla,et al.  Laser processed TiN reinforced Ti6Al4V composite coatings. , 2012, Journal of the mechanical behavior of biomedical materials.

[29]  Vamsi Krishna Balla,et al.  Laser processing of in situ synthesized TiB-TiN-reinforced Ti6Al4V alloy coatings , 2012 .