Impact of device selection and clip duration on lung ultrasound assessment in patients with heart failure.

OBJECTIVES Pulmonary edema is a common sign of heart failure and can be quantified by counting vertical artifacts (B-lines) on lung ultrasound (LUS). The primary aim of this study was to compare a pocket size ultrasound device to high-end ultrasound systems on the measured number of B-lines. We also compared the impact of different-length ultrasound clips on the measured number of B-lines. METHODS AND RESULTS We studied 21 hospitalized patients with heart failure (81% men; median age, 73; 71% Caucasian) who underwent concurrent 8- and 4-zone LUS using both a pocket ultrasound device and a high-end ultrasound system. For the 4-zone scanning method, the median B line number was 2 (interquartile range, 1-4) for the pocket device and 3 (1-5) for the high-end system (P = .67). For the 8-zone method, the median B-line number was 4 (2-7) for the pocket device and 5 (3-7) for the high-end system (P = .18). A higher number of B-lines was identified on the 4- vs 2-second LUS clips (P < .001 for 4 zones, P = .001 for 8 zones), and on the 6- vs 4-second LUS clips (P=0.057 for 4 zones, P=0.018 for 8 zones). CONCLUSIONS Our findings suggest significant differences based on LUS clip duration rather than the type of ultrasound device used, with respect to the number of B-lines detectable in patients with heart failure. These factors should be considered in the design and reporting of LUS studies and in longitudinal assessments of heart failure patients.

[1]  Kazuo Haze,et al.  A novel and simple method using pocket-sized echocardiography to screen for aortic stenosis. , 2013, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[2]  N. Montano,et al.  Standard and pocket-size lung ultrasound devices can detect interstitial lung disease in rheumatoid arthritis patients. , 2014, Rheumatology.

[3]  V. Noble,et al.  Ultrasound assessment for extravascular lung water in patients undergoing hemodialysis. Time course for resolution. , 2009, Chest.

[4]  P. Ponikowski,et al.  Assessing and grading congestion in acute heart failure: a scientific statement from the Acute Heart Failure Committee of the Heart Failure Association of the European Society of Cardiology and endorsed by the European Society of Intensive Care Medicine , 2010, European journal of heart failure.

[5]  N. Ayas,et al.  Does this dyspneic patient in the emergency department have congestive heart failure? , 2005, JAMA.

[6]  A. Sargsyan,et al.  International evidence-based recommendations for point-of-care lung ultrasound , 2012, Intensive Care Medicine.

[7]  L. A. Bonet,et al.  ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure 2012 , 2012, Turk Kardiyoloji Dernegi arsivi : Turk Kardiyoloji Derneginin yayin organidir.

[8]  C. Zoccali,et al.  Detection of pulmonary congestion by chest ultrasound in dialysis patients. , 2010, JACC. Cardiovascular imaging.

[9]  A. Hoes,et al.  Guidelines for the diagnosis and treatment of chronic heart failure: executive summary (update 2005): The Task Force for the Diagnosis and Treatment of Chronic Heart Failure of the European Society of Cardiology. , 2005, European heart journal.

[10]  Jens-Uwe Voigt,et al.  Diagnostic accuracy of a hand-held ultrasound scanner in routine patients referred for echocardiography. , 2011, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[11]  P. Johansson,et al.  Imaging Congestion With a Pocket Ultrasound Device: Prognostic Implications in Patients With Chronic Heart Failure. , 2015, Journal of cardiac failure.

[12]  M. Gheorghiade,et al.  Ultrasound lung comets for the differential diagnosis of acute cardiogenic dyspnoea: A comparison with natriuretic peptides ☆ , 2008, European journal of heart failure.

[13]  G. Trovato,et al.  Echocardiographic and Lung Ultrasound Characteristics in Ambulatory Patients with Dyspnea or Prior Heart Failure , 2014, Echocardiography.

[14]  N. Panebianco,et al.  Inter‐Rater Reliability of Quantifying Pleural B‐Lines Using Multiple Counting Methods , 2013, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[15]  V. Noble,et al.  Emergency thoracic ultrasound in the differentiation of the etiology of shortness of breath (ETUDES): sonographic B-lines and N-terminal pro-brain-type natriuretic peptide in diagnosing congestive heart failure. , 2009, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine.

[16]  R. Lewiss,et al.  Impact of patient positioning on lung ultrasound findings in acute heart failure , 2015, European heart journal. Acute cardiovascular care.

[17]  L. Cardinale,et al.  Bedside ultrasound of the lung for the monitoring of acute decompensated heart failure. , 2008, The American journal of emergency medicine.

[18]  Akshay S. Desai,et al.  Utility of lung ultrasound in predicting pulmonary and cardiac pressures , 2012, European journal of heart failure.

[19]  G. Janvier,et al.  Evaluation of a new pocket echoscopic device for focused cardiac ultrasonography in an emergency setting , 2012, Critical Care.

[20]  Pierre Kory,et al.  Impact of pocket ultrasound use by internal medicine housestaff in the diagnosis of dyspnea. , 2014, Journal of hospital medicine.

[21]  Volkmar Falk,et al.  2016 ESC Guidelines for the Diagnosis and Treatment of Acute and Chronic Heart Failure. , 2016, Revista espanola de cardiologia.