Sliding-mode control of a DFIG-based wind turbine under non-ideal grid voltages

Control algorithms for the rotor- and grid-side power converters of a double-fed induction generator (DFIG)-based wind turbine under non-ideal grid voltage conditions are proposed, and guidelines for tuning the controller parameters are presented. The control schemes are based on sliding-mode control (SMC) theory. Apart from directly controlling the DFIG's average active and reactive powers, the proposed methods also fulfil two additional control targets during voltage unbalance and harmonic distortion, that is, the rotor-side converter (RSC) eliminating electromagnetic torque fluctuations and the gridside converter (GSC) compensating for the stator current harmonics to ensure a sinusoidal total current from the overall generating unit. The described control strategies are proved to be robust against parameter deviations and of fast dynamic response. In spite of the discontinuous nature of the standard SMC, constant converter switching frequency is achieved. Besides, the RSC control algorithm does not require a phase-locked loop and, furthermore, there is no need for decomposing the grid voltage and different currents into symmetrical sequences or harmonic components in any of the converters' control systems. Finally, the excellent performance of the system, as well as its robustness, is verified by means of simulation results under different grid voltage conditions.

[1]  Dehong Xu,et al.  Stator Current Harmonic Control With Resonant Controller for Doubly Fed Induction Generator , 2012, IEEE Transactions on Power Electronics.

[2]  Lie Xu,et al.  Coordinated Control of DFIG's Rotor and Grid Side Converters During Network Unbalance , 2008, IEEE Transactions on Power Electronics.

[3]  D. Santos-Martin,et al.  Providing Ride-Through Capability to a Doubly Fed Induction Generator Under Unbalanced Voltage Dips , 2009, IEEE Transactions on Power Electronics.

[4]  Lei Shang,et al.  Sliding-Mode-Based Direct Power Control of Grid-Connected Wind-Turbine-Driven Doubly Fed Induction Generators Under Unbalanced Grid Voltage Conditions , 2012, IEEE Transactions on Energy Conversion.

[5]  G. Tapia,et al.  Modeling and control of a wind turbine driven doubly fed induction generator , 2003 .

[6]  Jiabing Hu,et al.  Reinforced Control and Operation of DFIG-Based Wind-Power-Generation System Under Unbalanced Grid Voltage Conditions , 2009, IEEE Transactions on Energy Conversion.

[7]  Heng Nian,et al.  Dynamic Modeling and Improved Control of DFIG Under Distorted Grid Voltage Conditions , 2011, IEEE Transactions on Energy Conversion.

[8]  Vadim I. Utkin,et al.  Sliding mode control design principles and applications to electric drives , 1993, IEEE Trans. Ind. Electron..

[9]  Luis Marroyo,et al.  Ride Through of Wind Turbines With Doubly Fed Induction Generator Under Symmetrical Voltage Dips , 2009, IEEE Transactions on Industrial Electronics.

[10]  Wei-Jen Lee,et al.  Effects of Voltage Unbalance and System Harmonics on the Performance of Doubly Fed Induction Wind Generators , 2010 .

[11]  G Abad,et al.  Direct Torque Control for Doubly Fed Induction Machine-Based Wind Turbines Under Voltage Dips and Without Crowbar Protection , 2010, IEEE Transactions on Energy Conversion.

[12]  Roberto Cárdenas,et al.  Sensorless Control of Doubly-Fed Induction Generators Using a Rotor-Current-Based MRAS Observer , 2008, IEEE Transactions on Industrial Electronics.

[13]  Heng Nian,et al.  Direct Active and Reactive Power Regulation of DFIG Using Sliding-Mode Control Approach , 2010, IEEE Transactions on Energy Conversion.

[14]  Barry W. Williams,et al.  Improved Control of DFIG Systems During Network Unbalance Using PI–R Current Regulators , 2009, IEEE Transactions on Industrial Electronics.

[15]  M. Itsaso Martinez,et al.  Sliding-Mode Control for DFIG Rotor- and Grid-Side Converters Under Unbalanced and Harmonically Distorted Grid Voltage , 2012, IEEE Transactions on Energy Conversion.

[16]  G. Abad,et al.  Direct Power Control of Doubly-Fed-Induction-Generator-Based Wind Turbines Under Unbalanced Grid Voltage , 2010, IEEE Transactions on Power Electronics.

[17]  Jiabing Hu,et al.  Operation of Wind-Turbine-Driven DFIG Systems Under Distorted Grid Voltage Conditions: Analysis and Experimental Validations , 2012, IEEE Transactions on Power Electronics.

[18]  Jie Wu,et al.  Integral Sliding-Mode Direct Torque Control of Doubly-Fed Induction Generators Under Unbalanced Grid Voltage , 2010, IEEE Transactions on Energy Conversion.

[19]  S. Arnalte,et al.  Direct Power Control Applied to Doubly Fed Induction Generator Under Unbalanced Grid Voltage Conditions , 2008, IEEE Transactions on Power Electronics.

[20]  J.A. Ferreira,et al.  Operation of Grid-Connected DFIG Under Unbalanced Grid Voltage Condition , 2009, IEEE Transactions on Energy Conversion.

[21]  Lie Xu,et al.  Dynamic Modeling and Control of DFIG-Based Wind Turbines Under Unbalanced Network Conditions , 2007, IEEE Transactions on Power Systems.

[22]  Peng Zhou,et al.  Improved Direct Power Control of a DFIG-Based Wind Turbine During Network Unbalance , 2009, IEEE Transactions on Power Electronics.