Study on Loss Detection Algorithms Using Tank Monitoring Data

An application of solution monitoring to material balance evaluation has been investigated with actual data from the Solution Monitoring Management System (SMMS) in the Tokai Reprocessing Plant (TRP). Loss detection capabilities of the proposed multivariate statistical methods are examined numerically for a simulated loss corresponding to parameters of a significant quantity in the wait mode. Multiscale statistical analysis as well as multivariate cumulative sum analysis are successfully used to demonstrate the protracted-loss detection. Because the actual tank data is composed of records in both the wait and transfer modes, the tank-to-tank transferring data is extracted from the sequence of monitoring data, and the error model effectiveness is evaluated in comparison with calculations. Although the data taken from the SMMS does not describe the entire solution process, an extended application of solution monitoring to the nuclear material accounting is advanced using the plant data, and future research subjects are described.