Beat-to-beat noise removal in noninvasive His-bundle electrocardiogram

His-bundle electrocardiogram micropotentials are usually obtained by serial-signal averaging, because no acceptable, satisfactory solution for beat-by-beat removal of power-line interference and electromyographic noise has been found. A method has been developed for surface beat-to-beat His-bundle potential recovery, with the hypothesis that no distortion in the signal shape is admissible. It is based on consecutive power-line interference subtraction and wavelet-domain electromyographic noise suppression, modified to match the strict criteria for detecting low-amplitude His potentials. The beat-to-beat wavelet-domain Wiener filtering uses a pilot signal estimate obtained from a limited number (around 20) of heart beat averages. The method resulted in an improvement of more than 4.5 dB in the signal-to-noise ratio and more than 20% reduction in mean absolute error, both measured along the P-Q segment. It is applicable for ECG signals contaminated by moderate electromyogram noise, with an initial signal-to-noise ratio of 15 dB or higher.

[1]  Jelena Kovacevic,et al.  Wavelets and Subband Coding , 2013, Prentice Hall Signal Processing Series.

[2]  T. Moon,et al.  Mathematical Methods and Algorithms for Signal Processing , 1999 .

[3]  I. Johnstone,et al.  Adapting to Unknown Smoothness via Wavelet Shrinkage , 1995 .

[4]  I. Christov,et al.  Filtering of electromyogram artifacts from the electrocardiogram. , 1999, Medical engineering & physics.

[5]  Richard G. Baraniuk,et al.  Analysis of wavelet-domain Wiener filters , 1998, Proceedings of the IEEE-SP International Symposium on Time-Frequency and Time-Scale Analysis (Cat. No.98TH8380).

[6]  S. Mallat A wavelet tour of signal processing , 1998 .

[7]  I.K. Duskalov,et al.  Developments in ECG acquisition, preprocessing, parameter measurement, and recording , 1998, IEEE Engineering in Medicine and Biology Magazine.

[8]  Karen O. Egiazarian,et al.  Denoising the electrocardiogram from electromyogram artifacts by combined transform-domain and dynamic approximation method , 2002, 2002 IEEE International Conference on Acoustics, Speech, and Signal Processing.

[9]  I. I. Christov,et al.  New approach to the digital elimination of 50 Hz interference from the electrocardiogram , 1988, Medical and Biological Engineering and Computing.

[10]  G. Wagner Marriott's Practical Electrocardiography , 1994 .

[11]  K. Egiazarian,et al.  Powerline interference suppression in high-resolution ECG , 2003, Computers in Cardiology, 2003.

[12]  Richard G. Baraniuk,et al.  Improved wavelet denoising via empirical Wiener filtering , 1997, Optics & Photonics.

[13]  Soo-Chang Pei,et al.  Elimination of AC interference in electrocardiogram using IIR notch filter with transient suppression , 1995, IEEE Transactions on Biomedical Engineering.

[14]  I. K. Daskalov,et al.  Subtraction of 50 Hz interference from the electrocardiogram , 2006, Medical and Biological Engineering and Computing.

[15]  C. L. Nikias,et al.  Algorithms for Statistical Signal Processing , 2002 .

[16]  B J Scherlag,et al.  Catheter Technique for Recording His Bundle Activity in Man , 1969, Circulation.

[17]  Atanas P. Gotchev,et al.  ECG signal denoising using wavelet domain wiener filtering , 2000, 2000 10th European Signal Processing Conference.

[18]  Noise coherence in closely-spaced electrodes: the implications for spatial averaged ECG recordings. , 1995, Journal of medical engineering & technology.

[19]  H. Schwan,et al.  Biological Engineering , 1970 .

[20]  C. A. Grimbergen,et al.  Method for the computation of an accurate zero reference for ECG signals , 2006, Medical and Biological Engineering and Computing.

[21]  Anil K. Jain Fundamentals of Digital Image Processing , 2018, Control of Color Imaging Systems.

[22]  K. Egiazarian,et al.  Suppression of electromyogram interference on the electrocardiogram by transform domain denoising , 2001, Medical and Biological Engineering and Computing.

[23]  L. Horan,et al.  Surface Recording of His‐Purkinje Activity on an Every‐beat Basis Without Digital Averaging , 1981, Circulation.

[24]  S. Mallat VI – Wavelet zoom , 1999 .

[25]  P. Defaye,et al.  Beat-to-beat detection of ventricular late potentials and His potential using the adaptive orthogonal projection , 1997, Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136).

[26]  Karen O. Egiazarian,et al.  Wavelet domain Wiener filtering for ECG denoising using improved signal estimate , 2000, 2000 IEEE International Conference on Acoustics, Speech, and Signal Processing. Proceedings (Cat. No.00CH37100).

[27]  I I Christov Dynamic powerline interference subtraction from biosignals , 2000, Journal of medical engineering & technology.