Coronary artery imaging: 3D segmented k‐space data acquisition with multiple breath‐holds and real‐time slab following

The purpose of this work was to develop a multiple‐breath‐hold (BH) imaging method for coronary arteries in which a segment of k‐space is acquired in each BH. The goal was to increase the resolution, or the signal‐to‐noise ratio (SNR) and coverage, of three‐dimensional‐(3D)‐BH volume‐targeted scanning (VCATS). To correct for slab position differences, a real‐time slab following technique using navigator echoes for motion detection was used. Sixteen normal volunteers were imaged to compare the method with a single‐BH scan. Results showed that higher resolution, or larger coverage and higher SNR, were achieved by the multiple‐BH method without respiratory motion artifacts. In conclusion, 3D segmented k‐space data acquisition with multiple‐BHs and real‐time slab following is a promising approach for extending the capabilities of VCATS further. J. Magn. Reson. Imaging 2001;13:301–307. © 2001 Wiley‐Liss, Inc.

[1]  E M Haacke,et al.  Three-dimensional gadolinium-enhanced coronary magnetic resonance angiography: initial experience. , 1999, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[2]  Y Wang,et al.  3D coronary MR angiography in multiple breath‐holds using a respiratory feedback monitor , 1995, Magnetic resonance in medicine.

[3]  M. McConnell,et al.  Comparison of respiratory suppression methods and navigator locations for MR coronary angiography. , 1997, AJR. American journal of roentgenology.

[4]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.

[5]  D. Pennell,et al.  Calculation of a subject-specific adaptive motion-correction factor for improved real-time navigator echo-gated magnetic resonance coronary angiography. , 1999, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[6]  C. Lorenz,et al.  Quantification of in‐plane motion of the coronary arteries during the cardiac cycle: Implications for acquisition window duration for MR flow quantification , 1998, Journal of magnetic resonance imaging : JMRI.

[7]  Albert Macovski,et al.  Coronary Angiography with Magnetization‐Prepared T2 Contrast , 1995, Magnetic resonance in medicine.

[8]  E. Grabbe,et al.  Konturschärfenbestimmung in der kontrastmittelunterstützten MR-Angiographie: Definition und klinische Evaluation am Beispiel der EKG-getriggerten Darstellung der thorakalen Aorta , 1998 .

[9]  M. Funke,et al.  [Determination of contour clarity in contrast-enhanced MR angiography: definition and clinical evaluation exemplified by ECG-triggered imaging of the thoracic aorta]. , 1998, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[10]  Y. Wang,et al.  Cardiac motion of coronary arteries: variability in the rest period and implications for coronary MR angiography. , 1999, Radiology.

[11]  M. McConnell,et al.  Prospective adaptive navigator correction for breath‐hold MR coronary angiography , 1997, Magnetic resonance in medicine.

[12]  René M. Botnar,et al.  Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA. , 1999, Circulation.

[13]  G Johnson,et al.  A Methodology for co‐registering abdominal MR images over multiple breath‐holds , 1995, Magnetic resonance in medicine.

[14]  R R Edelman,et al.  Coronary arteries: breath-hold, gadolinium-enhanced, three-dimensional MR angiography. , 1998, Radiology.

[15]  Todd S. Sachs,et al.  The diminishing variance algorithm for real‐time reduction of motion artifacts in MRI , 1995, Magnetic resonance in medicine.

[16]  René M. Botnar,et al.  Relationship between motion of coronary arteries and diaphragm during free breathing: lessons from real-time MR imaging. , 1999, AJR. American journal of roentgenology.

[17]  A. Duerinckx,et al.  Two-dimensional coronary MR angiography: analysis of initial clinical results. , 1994, Radiology.

[18]  Richard L. Ehman,et al.  A monitoring, feedback, and triggering system for reproducible breath‐hold MR imaging , 1993, Magnetic resonance in medicine.

[19]  S. Riederer,et al.  Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography. , 1996, Radiology.

[20]  R. Edelman,et al.  Coronary arteries: breath-hold MR angiography. , 1991, Radiology.

[21]  R. Henkelman Measurement of signal intensities in the presence of noise in MR images. , 1985, Medical physics.

[22]  P J de Feyter,et al.  Breath-hold coronary MR angiography with volume-targeted imaging. , 1998, Radiology.

[23]  D. Firmin,et al.  Phase ordering with automatic window selection (PAWS): A novel motion‐resistant technique for 3D coronary imaging , 2000, Magnetic resonance in medicine.

[24]  E M Haacke,et al.  MRI of Coronary Arteries: 2D Breath‐Hold vs 3D Respiratory‐Gated Acquisition , 1995, Journal of computer assisted tomography.

[25]  S. Riederer,et al.  Respiratory Motion of the Heart: Kinematics and the Implications for the Spatial Resolution in Coronary Imaging , 1995, Magnetic resonance in medicine.

[26]  F R Gutierrez,et al.  Coronary arteries: three-dimensional MR imaging with retrospective respiratory gating. , 1996, Radiology.

[27]  S. Wickline,et al.  Coronary Artery Diameter Determination from Contrast Enhanced MR Angiography ; Comparison with Selective X-ray Contrast Angiography , 2022 .

[28]  R. Pettigrew,et al.  Two-dimensional coronary MR angiography without breath holding. , 1996, Radiology.

[29]  R. Edelman,et al.  A preliminary report comparing magnetic resonance coronary angiography with conventional angiography. , 1993, The New England journal of medicine.