A CdZnTe slot-scanned detector for digital mammography.

A new high-resolution detector has been developed for use in a slot-scanned digital mammography system. The detector is a hybrid device that consists of a CCD operating in time-delay integration mode that is bonded to a 150-microm-thick CdZnTe photoconductor array. The CCD was designed with a detector element pitch of 50 microm. Two devices were evaluated with differing crystalline quality. Incomplete charge collection was a source of reduction in DQE. This occurs in both devices due to characteristically low mobility-lifetime products for CdZnTe, with the greatest losses demonstrated by the multicrystalline sample. The mobility-lifetime products for the multicrystalline device were found to be 2.4 x 10(-4) and 4.0 x 10(-7) cm2/V for electrons and holes, respectively. The device constructed with higher quality single crystal CdZnTe demonstrated mobility-lifetime products of 1.0 x 10(-4) and 4.4 x 10(-6) cm2/V for electrons and holes. The MTF and DQE for the device were measured at several exposures and results were compared to predictions from a linear systems model of signal and noise propagation. The MTF at a spatial frequency of 10 mm(-1) exceeded 0.18 and 0.56 along the scan and slot directions, respectively. Scanning motion and CCD design limited the resolution along the scan direction. For an x-ray beam from a tungsten target tube with 40 microm molybdenum filtration operated at 26 kV, the single crystal device demonstrated a DQE(0) of 0.70 +/- 0.02 at 7.1 x 10(-6) C/kg (27 mR) exposure to the detector, despite its relatively poor charge collection efficiency.

[1]  Y. Nemirovsky,et al.  Statistical models for charge collection efficiency and variance in semiconductor spectrometers , 1997 .

[2]  P. Judy,et al.  The line spread function and modulation transfer function of a computed tomographic scanner. , 1976, Medical physics.

[3]  Kunio Doi,et al.  A simple method for determining the modulation transfer function in digital radiography , 1992, IEEE Trans. Medical Imaging.

[4]  J A Rowlands,et al.  X-ray imaging with amorphous selenium: detective quantum efficiency of photoconductive receptors for digital mammography. , 1995, Medical physics.

[5]  J. A. Jenkins,et al.  Development of IMARAD CZT detectors with PIN contacts , 1999, Optics & Photonics.

[6]  Martin J Yaffe,et al.  Direct conversion detectors: the effect of incomplete charge collection on detective quantum efficiency. , 2002, Medical physics.

[7]  Yael Nemirovsky,et al.  Recent progress in n-type CdZnTe arrays for gamma-ray spectroscopy , 2001 .

[8]  R. K. Swank Absorption and noise in x‐ray phosphors , 1973 .

[9]  Yael Nemirovsky,et al.  CdZnTe photodiode arrays for medical imaging , 1996 .

[10]  William P. Dillon,et al.  Cd1-xZnxTe detector imaging array , 1993, Medical Imaging.

[11]  Richard M. Swanson,et al.  Modelling of minority-carrier transport in heavily doped silicon emitters , 1987 .

[12]  Martin J Yaffe,et al.  A slot-scanned photodiode-array/CCD hybrid detector for digital mammography. , 2002, Medical physics.

[13]  Arnold Burger,et al.  Effect of surfaces on the performance of CdZnTe detectors , 2001, SPIE Optics + Photonics.

[14]  I A Cunningham,et al.  Parallel cascades: new ways to describe noise transfer in medical imaging systems. , 2001, Medical physics.

[15]  Rodney Shaw,et al.  Signal-to-noise optimization of medical imaging systems , 1999 .

[16]  Yael Nemirovsky,et al.  Methodology for evaluation of mobility-lifetime product by spectroscopy measurements in CdZnTe spectrometers , 1997 .

[17]  Eustace L. Dereniak,et al.  Development of a 64 × 64 CdZnTe array and associated readout integrated circuit for use in nuclear medicine , 1997 .