Aortic aneurysm sac pressure measurements after endovascular repair using an implantable remote sensor: initial experience and short-term follow-up

The purpose of this single-center study was to report our initial experience with an implantable remote pressure sensor for aneurysm sac pressure measurement in patients post-endovascular aneurysm repair (EVAR) including short-term follow-up. A pressure sensor (EndoSure, Atlanta, GA) was implanted in 12 patients treated with different commercially available aortic endografts for EVAR. Pressure was read pre- and post-EVAR in the operating room. One-month follow-up (30 days ± 6 days) was performed including sac pressure readings and IV contrast CT scans. Variables were compared using the paired Student’s t test. An intraprocedure type-I endoleak and a type-III endoleak were successfully treated resulting in decreasing sac pressures. In all patients, post-EVAR systolic sac pressure decreased by an average of 33% (P ≤ 0.005) compared to pre-EVAR measurements. One-month follow-up demonstrated a 47% decrease in systolic sac pressure (P ≤ 0.05). On follow-up CT scans, the average maximum aneurysm diameter pre-EVAR was 6.3 ± 1.6 cm and post-EVAR 6.0 ± 1.7 cm (P≤0.05). The diameter of the aneurysm sac was larger only in one patient with a type-III endoleak. Remote sac pressure measurement may provide important information in addition to imaging and may help to reduce the number of follow-up CT scans.

[1]  T. Resch,et al.  Aneurysm pressure following endovascular exclusion. , 1997, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[2]  D. Gould,et al.  Endotension after Endovascular Aneurysm Repair: Definition, Classification, and Strategies for Surveillance and Intervention , 1999, Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery.

[3]  B. Hopkinson,et al.  Rupture of an abdominal aortic aneurysm secondary to type II endoleak. , 2001, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[4]  R. Fairman,et al.  Aneurysm sac pressure measurements after endovascular repair of abdominal aortic aneurysms. , 2001, Journal of vascular surgery.

[5]  M. Addis,et al.  First experience in human beings with a permanently implantable intrasac pressure transducer for monitoring endovascular repair of abdominal aortic aneurysms. , 2004, Journal of vascular surgery.

[6]  Jafar Golzarian,et al.  Endoleakage after endovascular treatment of abdominal aortic aneurysms: diagnosis, significance and treatment , 2006, European Radiology.

[7]  Rodney A. White,et al.  Initial results of wireless pressure sensing for endovascular aneurysm repair: the APEX Trial--Acute Pressure Measurement to Confirm Aneurysm Sac EXclusion. , 2007, Journal of vascular surgery.

[8]  Thomas Schmitz-Rode,et al.  Detecting endoleaks after endovascular AAA repair with a minimally invasive, implantable, telemetric pressure sensor: an in vitro study , 2007, European Radiology.

[9]  P. Faries,et al.  An Experimental Model for the Acute and Chronic Evaluation of Intra-Aneurysmal Pressure , 1997, Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery.

[10]  P. Harris,et al.  Can Intrasac Pressure Monitoring Reliably Predict Failure of Endovascular Aneurysm Repair? , 2003, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[11]  Krassi Ivancev,et al.  Intra-aneurysm pressure measurements in successfully excluded abdominal aortic aneurysm after endovascular repair. , 2003, Journal of vascular surgery.

[12]  N. Morrissey,et al.  Endovascular Stent Graft Repair of Abdominal and Thoracic Aortic Aneurysms: A Ten-Year Experience With 817 Patients , 2003, Annals of surgery.

[13]  Kevin E Bennet,et al.  Noninvasive measurement of aortic aneurysm sac tension with vibrometry. , 2005, Journal of vascular surgery.

[14]  Hironori Tanaka,et al.  Infrarenal Abdominal Aortic Aneurysm Complicated by Persistent Endotension After Endovascular Repair: Report of a Case , 2005, Surgery Today.

[15]  An Experimental Model for the Acute and Chronic Evaluation of Intra-Aneurysmal Pressure , 1997, Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery.

[16]  Rodney A. White,et al.  Nature and significance of endoleaks and endotension: summary of opinions expressed at an international conference. , 2002, Journal of vascular surgery.

[17]  A. Moskowitz,et al.  A statewide experience with endovascular abdominal aortic aneurysm repair: rapid diffusion with excellent early results. , 2004, Journal of vascular surgery.

[18]  S. Stevens,et al.  Endotension distribution and the role of thrombus following endovascular AAA exclusion. , 2002, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[19]  P. Faries,et al.  Chronic intraaneurysmal pressure measurement: an experimental method for evaluating the effectiveness of endovascular aortic aneurysm exclusion. , 1997, Journal of vascular surgery.

[20]  F. Veith,et al.  Endoleaks after endovascular graft treatment of aortic aneurysms: classification, risk factors, and outcome. , 1998, Journal of vascular surgery.

[21]  P. Faries,et al.  Evaluation of the accuracy of a wireless pressure sensor in a canine model of retrograde-collateral (type II) endoleak and correlation with histologic analysis. , 2006, Journal of vascular surgery.

[22]  J. Parodi,et al.  Transfemoral intraluminal graft implantation for abdominal aortic aneurysms , 1991, Annals of vascular surgery.