Can intraoperative ultrasound visualize the closed reduction and elastic intramedullary nail fixation processes of double forearm fractures in children?

Abstract To evaluate the feasibility of utilizing ultrasonography to monitor the fracture reduction and elastic intramedullary nail fixation processes in treating children with double forearm fractures. A retrospective analysis of 30 children with double forearm fractures treated at our hospital between January 2016 and July 2018. The children were aged 3 to 10 years. All patients were treated with closed reduction and internal fixation with elastic intramedullary nails using intraoperative ultrasound monitoring and intermittent radiographic imaging. The closed reduction and fixation were successful in all patients. The operation times ranged from 16 to 30 minutes, averaging 21 minutes. No neurovascular injuries occurred during closed reduction and nail insertion. Moreover, closed reduction was successful in the first attempt in 86.7% of patients. All patient outcomes were optimal, lacking serious complications during follow-ups. Intraoperative ultrasound monitoring can clearly show the shape and changes in fracture ends, distal growth plates, and surrounding soft tissues, and fracture reduction and passage of elastic nail processes at fracture ends during closed reduction; therefore, visualizing closed reductions can be achieved. The combination of intraoperative ultrasound and radiographic imaging can ensure operative effects and significantly reduce radiation exposure for both doctors and patients. An adequately powered prospective randomized trial is required to confirm our findings.

[1]  S. Min,et al.  Ultrasound assessment of the anatomic landmarks for spinal anesthesia in elderly patients with hip fracture , 2019, Medicine.

[2]  A. Hazra,et al.  Ultrasound detected changes in joint cartilage thickness in juvenile idiopathic arthritis , 2019, International journal of rheumatic diseases.

[3]  Shuisheng Yu,et al.  A safe percutaneous technique for the reduction of irreducible femoral neck fractures using ultrasound localization of the femoral vascular and nervous structures at the hip , 2019, Medicine.

[4]  S. Bianchi,et al.  Ultrasound Evaluation of Sesamoid Fractures of the Hand: Retrospective Report of 13 Patients , 2018, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[5]  F. Fallahi,et al.  The role of ultrasonography in the diagnosis of occult scaphoid fractures , 2018, Journal of ultrasonography.

[6]  J. Pace Pediatric and Adolescent Forearm Fractures: Current Controversies and Treatment Recommendations , 2016, The Journal of the American Academy of Orthopaedic Surgeons.

[7]  D. Song,et al.  Isolated ring finger flexor digitorum profundus entrapment after closed reduction and intramedullary fixation of both-bone forearm fracture. , 2012, Orthopedics.

[8]  Ulrica Bergström,et al.  Epidemiology of fractures in children and adolescents , 2010, Acta orthopaedica.

[9]  S. A. Qidwai Treatment of diaphyseal forearm fractures in children by intramedullary Kirschner wires. , 2001, The Journal of trauma.

[10]  B. Mahaisavariya,et al.  Ultrasound or image intensifier for closed femoral nailing. , 1993, The Journal of bone and joint surgery. British volume.

[11]  D. S. Scott,et al.  Malunited Forearm Fractures in Children , 1990, Journal of pediatric orthopedics.

[12]  P. Lascombes,et al.  Elastic Stable Intramedullary Nailing in Forearm Shaft Fractures in Children: 85 Cases , 1990, Journal of pediatric orthopedics.