Airborne ultrasonic phased arrays using ferroelectrets: a new fabrication approach

In this work, a novel procedure that considerably simplifies the fabrication process of ferroelectret-based multi-element array transducers is proposed and evaluated. Also, the potential of ferroelectrets being used as active material for aircoupled ultrasonic transducer design is demonstrated. The new construction method of multi-element transducers introduces 2 distinctive improvements. First, active ferroelectret material is not discretized into elements, and second, the need of structuring upper and/or lower electrodes in advance of the permanent polarization of the film is removed. The aperture discretization and the mechanical connection are achieved in one step using a through-thickness conductive tape. To validate the procedure, 2 linear array prototypes of 32 elements, with a pitch of 3.43 mm and a wide usable frequency range from 30 to 300 kHz, were built and evaluated using a commercial phased-array system. A low crosstalk among elements, below -30 dB, was measured by interferometry. Likewise, a homogeneous response of the array elements, with a maximum deviation of plusmn1.8 dB, was obtained. Acoustic beam steering measurements were accomplished at different deflection angles using a calibrated microphone. The ultrasonic beam parameters, namely, lateral resolution, side lobe level, grating lobes, and focus depth, were congruent with theory. Acoustic images of a single reflector were obtained using one of the array elements as the receiver. Resulting images are also in accordance with numerical simulation, demonstrating the feasibility of using these arrays in pulse-echo mode. The proposed procedure simplifies the manufacturing of multidimensional arrays with arbitrary shape elements and not uniformly distributed. Furthermore, this concept can be extended to nonflat arrays as long as the transducer substrate conforms to a developable surface.

[1]  José Luis San Emeterio,et al.  Diffraction impulse response of rectangular transducers , 1992 .

[2]  D. Wildes,et al.  The acoustic lens design and in vivo use of a multifunctional catheter combining intracardiac ultrasound imaging and electrophysiology sensing , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[3]  C. Fritsch,et al.  Digital signal processing techniques for high accuracy ultrasonic range measurements , 1991 .

[4]  Werner Wirges,et al.  Controlled inflation of voids in cellular polymer ferroelectrets: Optimizing electromechanical transducer properties , 2004 .

[5]  J.A. Hossack,et al.  An approach for reducing adjacent element crosstalk in ultrasound arrays , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[6]  Gerhard M. Sessler,et al.  DC-biased ferroelectrets with large piezoelectric d33-coefficients , 2008 .

[7]  D. E. Chimenti,et al.  Design, Fabrication and Characterization of a Spherically Focused Capacitive Air-Coupled Ultrasonic Transducer , 2006 .

[8]  G. Kino Acoustic waves : devices, imaging, and analog signal processing , 1987 .

[9]  R. Gibney,et al.  Technical report. Intra-operative ultrasound-guided needle localization for impalpable testicular lesions. , 2003, Clinical radiology.

[10]  Andy Hopper,et al.  Broadband ultrasonic location systems for improved indoor positioning , 2006, IEEE Transactions on Mobile Computing.

[11]  P.D. Wilcox,et al.  Advanced Reflector Characterization with Ultrasonic Phased Arrays in NDE Applications , 2007, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[12]  R. Danz,et al.  8F-4 Ultrasound Phased Array for Airborne Applications Based on Cellular Polymer , 2007, 2007 IEEE Ultrasonics Symposium Proceedings.

[13]  R. Kressmann,et al.  New piezoelectric polymer for air-borne and water-borne sound transducers. , 2001, The Journal of the Acoustical Society of America.

[14]  Reimund Gerhard-Multhaupt,et al.  Less can be more. Holes in polymers lead to a new paradigm of piezoelectric materials for electret transducers , 2002 .

[15]  J.L. Ealo,et al.  Broadband EMFi-based transducers for ultrasonic air applications , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[16]  Santina Rocchi,et al.  A 3D airborne ultrasound scanner , 1998 .

[17]  Anton Erhard,et al.  Ferroelectret non-contact ultrasonic transducers , 2007 .

[18]  Minoru Toda,et al.  PVDF corrugated transducer for ultrasonic ranging sensor , 2007 .

[19]  D. Hutchins,et al.  Imaging using air-coupled polymer-membrane capacitive ultrasonic arrays. , 2004, Ultrasonics.

[20]  Gordon Hayward,et al.  A facet ensemble approach for evaluation of array performance in ultrasonic NDE , 1990, IEEE Symposium on Ultrasonics.

[21]  Ningqun Guo,et al.  Beam pattern calculation for optimization of broadband array transducers , 2006 .

[22]  Ph. Dumas,et al.  Piezocomposite technology An innovative approach to the improvement of N.D.T. performance using ultrasounds , 2002 .

[23]  Elgar Fleisch,et al.  Flexible-foam-based capacitive sensor arrays for object detection at low cost , 2008 .

[24]  David A. Hutchins,et al.  Surface metrology using reflected ultrasonic signals in air , 2002 .

[25]  A. Atalar,et al.  P3R-4 Stagger Tuned cMUT Array for Wideband Airborne Applications , 2006, 2006 IEEE Ultrasonics Symposium.

[26]  B. Khuri-Yakub,et al.  A surface micromachined electrostatic ultrasonic air transducer , 1996, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[27]  Nils Kroemer,et al.  Ultrasonic transducers and transducer arrays for applications in air , 1992 .

[28]  Q. Wahab,et al.  New materials for micro-scale sensors and actuators An engineering review , 2007 .

[29]  J. Camacho,et al.  Protection circuits for ultrasound applications , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.