A Novel Testing Platform for Assessing Knee Joint Mechanics: A Parallel Robotic System Combined with an Instrumented Spatial Linkage

Assessing joint function following trauma and its inter-relation with degenerative changes requires an understanding of the normal state of structural loading in the joint. Very few studies have attempted to reproduce joint specific in vivo motions in vitro to quantify the actual loads carried by different tissues within the knee joint. The most significant challenge in this area is the very high sensitivity of the loads in joint structures to motion reproduction accuracy. A novel testing platform for assessing knee joint mechanics is described, comprised of a highly accurate (0.3 ± 0.1 mm, 0.3 ± 0.1°) six-degree-of-freedom (6-DOF) instrumented spatial linkage (ISL) for in vivo joint kinematic assessments and a unique 6-DOF parallel robotic manipulator. A position feedback system (ISL and position controller) is used for accurate reproduction of in vivo joint motions and estimation of “in situ” joint/tissue loads. The parallel robotic manipulator provides excellent stiffness and repeatability in reproducing physiological motions in 6-DOF, compared to the commonly used serial robots. The position feedback system provides real-time feedback data to the robot to reproduce in vivo motions and significantly enhances motion reproduction accuracy by adjusting for robot end-effector movements. Using this combined robot-ISL system, in vivo motions can be reproduced in vitro with very high accuracy (0.1 mm, 0.1°). Our results indicate that this level of accuracy is essential for meaningful estimation of tissue loads during gait. Using this novel testing platform, we have determined the normal load-carrying characteristics of different tissues within the ovine knee joint. The application of this testing system will continue to increase our understanding of normal and pathological joint states.

[1]  S. Woo,et al.  Contribution of biomechanics to management of ligament and tendon injuries. , 2008, Molecular & cellular biomechanics : MCB.

[2]  S. Woo,et al.  Tension patterns of the anteromedial and posterolateral grafts in a double‐bundle anterior cruciate ligament reconstruction , 2009, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[3]  Joo H. Kim,et al.  The potential of accelerometers in the evaluation of stability of total knee arthroplasty. , 2013, The Journal of arthroplasty.

[4]  Victor Sholukha,et al.  Calibration and validation of 6 DOFs instrumented spatial linkage for biomechanical applications. A practical approach. , 2004, Medical engineering & physics.

[5]  B. Beynnon,et al.  Anterior cruciate ligament strain in-vivo: a review of previous work. , 1998, Journal of biomechanics.

[6]  E S Grood,et al.  A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. , 1983, Journal of biomechanical engineering.

[7]  Janet L Ronsky,et al.  Dynamic in vivo kinematics of the intact ovine stifle joint , 2006, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[8]  C. Frank,et al.  Molecular biology and biomechanics of normal and healing ligaments--a review. , 1999, Osteoarthritis and cartilage.

[9]  Joshua M Rosvold,et al.  A comparison of passive flexion-extension to normal gait in the ovine stifle joint. , 2008, Journal of biomechanics.

[10]  S. Woo,et al.  Determination of a Safe Range of Knee Flexion Angles for Fixation of the Grafts in Double-Bundle Anterior Cruciate Ligament Reconstruction , 2007, The American journal of sports medicine.

[11]  Henry W. Stone,et al.  Kinematic Modeling, Identification, and Control of Robotic Manipulators , 1987 .

[12]  J L Lewis,et al.  6R instrumented spatial linkages for anatomical joint motion measurement--Part 2: Calibration. , 1992, Journal of biomechanical engineering.

[13]  Antonie J van den Bogert,et al.  Design and validation of a general purpose robotic testing system for musculoskeletal applications. , 2010, Journal of biomechanical engineering.

[14]  T P Andriacchi,et al.  Studies of human locomotion: past, present and future. , 2000, Journal of biomechanics.

[15]  Ali Hosseini,et al.  Anteroposterior stability of the knee during the stance phase of gait after anterior cruciate ligament deficiency. , 2012, Gait & posture.

[16]  Mohammad Atarod Pilambaraei,et al.  A safe overhang limit for unicompartmental knee arthroplasties based on medial collateral ligament strains: an in vitro study. , 2013, The Journal of arthroplasty.

[17]  Nigel G. Shrive,et al.  Functional Activity of the Anterior and Posterior Cruciate Ligaments Under In Vivo Gait and Static Physiological Loads , 2013, Annals of Biomedical Engineering.

[18]  Braden C. Fleming,et al.  In Vivo Measurement of Ligament/Tendon Strains and Forces: A Review , 2004, Annals of Biomedical Engineering.

[19]  D L Butler,et al.  Evaluation of an electromagnetic position tracking device for measuring in vivo, dynamic joint kinematics. , 2005, Journal of biomechanics.

[20]  S. B. Adams,et al.  The surgical anatomy of the stifle joint in sheep. , 1998, Veterinary surgery : VS.

[21]  Janet L Ronsky,et al.  Reproduction of in vivo motion using a parallel robot. , 2007, Journal of biomechanical engineering.

[22]  M. H. Pope,et al.  The measurement of anterior cruciate ligament strain in vivo , 2004, International Orthopaedics.

[23]  J M Rosvold,et al.  Technical issues in using robots to reproduce joint specific gait. , 2011, Journal of biomechanical engineering.

[24]  D J Schaeffer,et al.  Three-dimensional kinematics of the intact and cranial cruciate ligament-deficient stifle of dogs. , 1994, Journal of biomechanics.

[25]  Scott Tashman,et al.  In-vivo measurement of dynamic joint motion using high speed biplane radiography and CT: application to canine ACL deficiency. , 2003, Journal of biomechanical engineering.

[26]  Frances T Sheehan,et al.  Assessing the accuracy and precision of musculoskeletal motion tracking using cine-PC MRI on a 3.0T platform. , 2011, Journal of biomechanics.

[27]  C. Frank,et al.  There is significant load sharing and physical interaction between the anteromedial and posterolateral bundles of the ovine ACL under anterior tibial loads. , 2012, The Knee.

[28]  B. Fleming,et al.  Factors influencing the output of an implantable force transducer. , 2000, Journal of biomechanics.

[29]  J L Lewis,et al.  6R instrumented spatial linkages for anatomical joint motion measurement--Part 1: Design. , 1992, Journal of biomechanical engineering.

[30]  G A Livesay,et al.  A combined robotic/universal force sensor approach to determine in situ forces of knee ligaments. , 1996, Journal of biomechanics.

[31]  Thomas P Andriacchi,et al.  Rotational Changes at the Knee after ACL Injury Cause Cartilage Thinning , 2006, Clinical orthopaedics and related research.

[32]  S L Woo,et al.  Use of robotic technology for diathrodial joint research. , 1999, Journal of science and medicine in sport.

[33]  S. Woo,et al.  The forces in the anterior cruciate ligament and knee kinematics during a simulated pivot shift test: A human cadaveric study using robotic technology. , 2000, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.