In-plane MTF measurement using sphere phantoms for step-and-shoot mode and continuous mode digital tomosynthesis systems

In-plane modulation transfer function (MTF) has been widely used as a quantitative metric describing the spatial resolution of an in-plane image for a digital tomosynthesis system. Although the in-plane MTF was measured using fine wire and edge objects, precise phantom alignment along the measurement direction was one of challenging issues. To overcome this limitation, a sphere object was regarded as an alternative phantom because of spherically symmetric property. However, due to anisotropic property of tomosynthesis image, the sphere phantom has not been used to measure the in-plane MTF. In our previous work, we proposed the inverse filtering approach to measure the in-plane MTF using sphere phantoms. Using the inverse filtering approach, in this work, we measure the in-plane MTF of step-and-shoot mode and continuous mode digital tomosynthesis systems. We generated projection data of point and sphere objects in step-and-shoot mode and continuous mode tomosynthesis systems, and reconstructed using FDK algorithm. An in-plane image of reconstructed point volume was regarded as an ideal in-plane point spread function (PSF). The ideal in-plane MTF was calculated by taking Fourier transform of the ideal in-plane PSF, and fx-directional in-plane MTF was used as a reference. To measure fx-directional in-plane MTF, we divided the Fourier transform of reconstructed sphere phantom by that of ideal sphere object, and performed plane integral along the fz-direction. The estimation errors caused by inverse filtering were corrected by pseudo inverse filtering and Laplacian operator. Our results show that the in-plane MTFs of step-and-shoot mode and continuous mode are reliably estimated by the inverse filtering approach.

[1]  E Samei,et al.  Assessment of multi-directional MTF for breast tomosynthesis , 2013, Physics in medicine and biology.

[2]  Bo Zhao,et al.  A computer simulation platform for the optimization of a breast tomosynthesis system. , 2007, Medical physics.

[3]  W. Marsden I and J , 2012 .

[4]  Jongduk Baek,et al.  Inverse filtering approach to measure directional in-plane modulation transfer function using a sphere phantom for a digital tomosynthesis system. , 2017, Optics express.

[5]  Rafael C. González,et al.  Local Determination of a Moving Contrast Edge , 1985, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[6]  I. Sechopoulos A review of breast tomosynthesis. Part II. Image reconstruction, processing and analysis, and advanced applications. , 2013, Medical physics.

[7]  Jongduk Baek,et al.  A Sphere Phantom Approach to Measure Directional Modulation Transfer Functions for Tomosynthesis Imaging Systems , 2016, IEEE Transactions on Medical Imaging.

[8]  Aruna A. Vedula,et al.  A computer simulation study comparing lesion detection accuracy with digital mammography, breast tomosynthesis, and cone-beam CT breast imaging. , 2006, Medical physics.

[9]  Jiang Hsieh,et al.  Computed Tomography: Principles, Design, Artifacts, and Recent Advances, Fourth Edition , 2022 .

[10]  I. Sechopoulos A review of breast tomosynthesis. Part I. The image acquisition process. , 2013, Medical physics.

[11]  Bo Zhao,et al.  Imaging performance of an amorphous selenium digital mammography detector in a breast tomosynthesis system. , 2008, Medical physics.

[12]  Jongduk Baek,et al.  A New Method to Measure Directional Modulation Transfer Function Using Sphere Phantoms in a Cone Beam Computed Tomography System , 2015, IEEE Transactions on Medical Imaging.

[13]  Bin Zheng,et al.  Characterization of a high-energy in-line phase contrast tomosynthesis prototype. , 2015, Medical physics.